    MCP Series Uninterruptible Power Supply MCP 1000, MCP 1000i MCP 2000, MCP 2000i MCP 3000, MCP 3000i User ’ s Manual ...

  • Minuteman UPS MCP 1000 - page 2

    ...

  • Minuteman UPS MCP 1000 - page 3

    MCP Series User ’ s Manual 1 . Introduction 2 2 . Controls and Indicators 6 3. Installation 10 4. Operation 12 5 . T roubleshooting 14 6 . Replacing the Batteries 15 7 . Obtaining Service 17 8 . Specifications 18 9 . Limited Product W arranty 19 ã Copyright Para Systems, Inc., 1998 1 ...

  • Minuteman UPS MCP 1000 - page 4

    EXPLANA TION OF SYMBOLS Some or all of the following symbols may be used in this manual or may appear on your unit. Please take a moment to familiarize yourself with these symbols and their associ- ated meanings. 2 ...

  • Minuteman UPS MCP 1000 - page 5

    Thank you for purchasing a Minuteman power protection product. It has been designed and manufactured to provide many years of trouble free service. Please read the manual before installing your MCP Series UPS as it pro- vides the information that should be followed during installation and mainte- nance of the UPS and batteries allowing you to corre ...

  • Minuteman UPS MCP 1000 - page 6

    Receiving Inspection After removing your Minuteman UPS from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored. The packing materials that your UPS were shipped in are caref ...

  • Minuteman UPS MCP 1000 - page 7

    Para Systems Life Support Policy As a general policy , Para systems Inc. (Para Systems) does not recommend the use of any of its products in life support applications where failure or malfunction of the Para Systems product can be reasonably expected to cause failure of the life support device or to signifi- cantly affect its safety or effectivenes ...

  • Minuteman UPS MCP 1000 - page 8

    FRONT P ANEL MCP Series 1000(i), 2000(i), and 3000(i) KV A front panel POWER SWITCH Press and release the power switch button to turn the unit on or off. LED INDICA T ORS ON LINE LED: This indicates that the AC line is normal. ON BA TTER Y LED: This indicates that the UPS is in battery mode. BYP ASS LED: This indicates bypass is active. OVERLOAD LE ...

  • Minuteman UPS MCP 1000 - page 9

    REAR P ANEL The Computer Interface ports are for UPS monitoring and control. There are two female DB-9’s for interface connection, one for RS-232 communication and one for Dry Contact interface signals. The External Battery Connector is for adding more battery capacity to the UPS. Available on the MCP 2000(i) and MCP 3000(i) only . The TVSS Slot ...

  • Minuteman UPS MCP 1000 - page 10

    MCP 1000i Rear Panel MCP 2000 Rear Panel 8 ...

  • Minuteman UPS MCP 1000 - page 11

    MCP 2000i Rear Panel MCP 3000 Rear Panel 9 ...

  • Minuteman UPS MCP 1000 - page 12

    MCP 3000i Rear Panel INST ALLA TION PLACEMENT The safe and continuous operation of the UPS depends partially on the care taken by the user . Please note the following precautions: · Install the UPS in a temperature controlled, indoor environment that is free of conductive contaminants. · Select a location that will provide good air circulation fo ...

  • Minuteman UPS MCP 1000 - page 13

    COMPUTER INTERF ACE CONNECTIONS Minuteman Power Management software and interface cables kits are used with these ports (software and cables are optional and available from Minuteman). Use only Minuteman or Minuteman approved interface cables with these UPS’s. Connect the interface cable to the DB-9 connector on the rear of the UPS (either RS-232 ...

  • Minuteman UPS MCP 1000 - page 14

    NOTE: For hardwire I/O configurations for the MCP 2000(i) and the MCP 3000(i), units are considered fixed. When connecting equipment to hardwire I/O configurations ensure use of proper size gauge wires for all connections. CAUTION! DO NOT CONNECT A LASER PRINTER TO THE UPS UNLESS THE UPS IS RA TED 2000V A OR GREA TER. A LASER PRINTER DRA WS SIG- NI ...

  • Minuteman UPS MCP 1000 - page 15

    COMMUNICA TION INTERF ACE (1) RS232 NC----------------- 1 NC----------------- 6 TXD--------------- 2 NC----------------- 7 RXD--------------- 3 NC----------------- 8 NC----------------- 4 NC----------------- 9 Signal Ground--- 5 Pin2: UPS transmits serial data to computer . Pin3: UPS receives serial data from computer . Pin5: Signal ground. The RS2 ...

  • Minuteman UPS MCP 1000 - page 16

    TROUBLESHOOTING CHART Symtom UPS not on On Battery LED is illuminated even though there is normal AC present Fault LED is illuminated UPS does not provide expected backup time Overload LED is illuminated Battery Low LED is illuminated Communication does not work properly Possible Cause Power switch is in Off position. No incoming utility . Input AC ...

  • Minuteman UPS MCP 1000 - page 17

    REPLACING THE BA TTERIES W ARNING! This uninterruptible power source contains potentially hazardous voltages. It is recommended that you turn the UPS off and disconnect the input power cord from the receptacles prior to connecting or disconnecting the battery terminals. Only UPS’s that have external battery packs can be changed “HOT”, that is ...

  • Minuteman UPS MCP 1000 - page 18

    · If electrolyte contacts the skin, wash it off immediately with water . If electrolyte contacts the eyes, flush thoroughly and immediately with water . Seek medical attention. · Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground. Contact with any part of a grounded battery can result in electri ...

  • Minuteman UPS MCP 1000 - page 19

    IF THE UPS REQUIRES SERVICE 1. Use the TROUBLESHOOTING chart section 5 to eliminate obvious causes. 2. V erify that no circuit breakers are tripped. A tripped circuit breaker is the most common problem. 3. Call your dealer for assistance. If you cannot reach your dealer or if he cannot resolve the problem, call or fax Minuteman T echnical Support a ...

  • Minuteman UPS MCP 1000 - page 20

    0-138 (0-275 V AC) 88-138 (160-275 V AC) >0.97 120V AC (220/230/240 V AC) 0ms (true-on-line) 1000V A/700W ± 2% 50 or 60Hz auto-sensing Manual reset circuit breaker 50 or 60Hz ± 2Hz 3%(Linear load); 6%(Rectifier load) 1 Hz/sec 105%-125% for 3 min., 125%-150% for 30 sec., > 150% for 1 sec. 3:1 80% 120 V AC (230 V AC) ± 2% 50 or 60Hz ± 1 Hz ...

  • Minuteman UPS MCP 1000 - page 21

    LIMITED PRODUCT W ARRANTY Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period of three years from the date of original purchase by the end user . For equipment sites within the United States and Canada, this warranty covers rep ...

  • Minuteman UPS MCP 1000 - page 22

    NOTES: 20 ...

  • Minuteman UPS MCP 1000 - page 23

    ...

  • Minuteman UPS MCP 1000 - page 24

    Para Systems, Inc. 1455 Lemay Dr . Carrollton, TX 75007 Phone: (972) 446-7363 Fax: (972) 446-901 1 QuickFax Info Systems: 800-263-3933 www.minuteman-ups.com P/N: 34000130 REV: 0 ...

Manufacturer Minuteman UPS Category Power Supply

Documents that we receive from a manufacturer of a Minuteman UPS MCP 1000 can be divided into several groups. They are, among others:
- Minuteman UPS technical drawings
- MCP 1000 manuals
- Minuteman UPS product data sheets
- information booklets
- or energy labels Minuteman UPS MCP 1000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Minuteman UPS MCP 1000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Minuteman UPS MCP 1000, service manual, brief instructions and user manuals Minuteman UPS MCP 1000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Minuteman UPS MCP 1000.

A complete manual for the device Minuteman UPS MCP 1000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Minuteman UPS MCP 1000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Minuteman UPS MCP 1000.

A complete Minuteman UPS manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Minuteman UPS MCP 1000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Minuteman UPS MCP 1000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Minuteman UPS MCP 1000, that we can find in the current document
3. Tips how to use the basic functions of the device Minuteman UPS MCP 1000 - which should help us in our first steps of using Minuteman UPS MCP 1000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Minuteman UPS MCP 1000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Minuteman UPS MCP 1000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Minuteman UPS MCP 1000?

Use the form below

If you did not solve your problem by using a manual Minuteman UPS MCP 1000, ask a question using the form below. If a user had a similar problem with Minuteman UPS MCP 1000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)