Инструкция обслуживания Friedrich HazardGard 60 Hz

16 страниц 0.34 mb
Скачать

Перейти на страницу of 16

Summary
  • Friedrich HazardGard 60 Hz - page 1

    SH15L30-B SH20L30-B HG-SVC-PRTS-07 (3-07) R oom Air Conditioners 60 Hz Mode ls 20 0 7 Ser vi ce & P ar ts Manu al ...

  • Friedrich HazardGard 60 Hz - page 2

    2 T ABLE OF CONT EN TS Speci fi cations ...................................................................................................................... ................................... 3 Per formance Data ............................................................................................................. ........................ ...

  • Friedrich HazardGard 60 Hz - page 3

    3 EV APORA T OR AIR TEMP . DEG. F EV APORA TOR TEMP . DEG. F CONDENSER TEMP . DEG. F Discharge T emp Suction T emp Liquid T emp Super Heat Sub- Cooling OPERA TING PRESSURES ELECTRICAL RA TINGS R-22 REF . Evap CFM Motor RPM BREAKER FUSE Discharge Air T emp. Drop F . E(in) E(out) Suction Discharge Amps Cool Amps Heat Locked Rotor Amps Charge in OZ. 6 ...

  • Friedrich HazardGard 60 Hz - page 4

    4 COMPRESSOR WINDING TEST (Figure 2.) Remov e the c ompress or terminal box c over and disconnect the wires from t he terminals. Using an ohmmeter , c heck c ontinuit y across the follow ing: COMPONENT OPERA TION AND TESTING COM PRE SSO RS Compress ors are single phase, 208 /23 0 volt. All c ompres sor motors are per manent split capaci tor t ype, ...

  • Friedrich HazardGard 60 Hz - page 5

    5 F AN MOTOR (Figure 4) A 230 volt single phase per manent split capacitor m otor is used to drive the evaporator blower and condenser fan. A running c apacitor is wired acros s the star t and r un terminals of the motor . The motor is totally enc losed and is protected with a line volt- age overload located inter nally of the motor . The motor sha ...

  • Friedrich HazardGard 60 Hz - page 6

    6 THERMOST A T A cross ambient ther most at is used to maintain the desire d comfor t level . The ther most at reacts only to a change in temperature at the bulb location. Impor t ant to the succ essful operation of the unit is the posit ion of the sensing bulb in relation to the evaporator ( see Figure 8 ) . TEST Remove the wires from the ther mos ...

  • Friedrich HazardGard 60 Hz - page 7

    7 NOTE: This procedure can be sped up by the use of heat lamps, or by breaking the v acuum with refr igerant o r d r y n i t r o g e n a t 5 , 0 0 0 m i c r o n s . P r e s s u r e s y s t e m t o 5 PSIG and leave in the s ystem a minimum of 10 minutes. Recover refrigerant, and proceed wit h evacuation to a pressure of 20 0 micr ons or a minimum of ...

  • Friedrich HazardGard 60 Hz - page 8

    8 TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE TO CORRECT UNIT DO ES NOT RUN. Power disconnected. Check power source. System switch in “ O f f ” posit ion. Set switc h co rrec tly . Branch circuit f use blown or circuit breaker tripped. Replace fuse, reset breaker . If repeats, check f use or breaker size. Check for shor ts in unit wir ing and co mp ...

  • Friedrich HazardGard 60 Hz - page 9

    9 TROUBL ESHOOTING ( Continu ed) PROBLEM POSSIBLE CAUSE TO CORRECT COM PRES SOR AT T E M P T S T O ST ART , OR RUNS FO R S H O R T PERIOD S ON L Y . CYCL ES O N OV ER LOA D. Compress or attempts to st ar t before syst em pressures are equal ized. Allow a minimum of t wo (2 ) minutes to allow pres sures to equalize before attempting to star t. Low o ...

  • Friedrich HazardGard 60 Hz - page 10

    10 TROUBL ESHOOTING ( Continu ed) PROBLEM POSSIBLE CAUSE TO CORRECT F AN M OTOR DOES NOT R U N. Defective switch (On- Of f ). Check co ntinuit y across ter minals 2 and 3. F an capacitor open. Check by substituting a known go od c apacitor of the s ame rating . Inoperative fan motor . Direct test fan m otor . Incor rec t wiring of fan c ircuit. Con ...

  • Friedrich HazardGard 60 Hz - page 11

    11 WIRING DIA GR AM MODELS SH 1 5L30 - B and SH20L30 - B ...

  • Friedrich HazardGard 60 Hz - page 12

    12 HAZARDGARD CABINET P ARTS ...

  • Friedrich HazardGard 60 Hz - page 13

    13 HAZARDGARD CHASSIS P ARTS ...

  • Friedrich HazardGard 60 Hz - page 14

    14 HAZARDGARD P ARTS LIST REF DESCRIPTION P ART NO# MODELS CODE ELECTRICAL P ARTS SH15L30-B SH20L30-B 1 COMPRESSOR 61 193549 1 600 1 COMPRESSOR 61 193550 1 600 2 MOTOR, F AN 61871426 11 1 0 2 MOTOR, F AN 61871427 11 1 0 5 SWITCH, ON-OFF DPST 60935300 1 1 130 * INSULA TOR, ELECTRICAL 61829700 1 1 399 * RELA Y , SOLID ST A TE 61 108800 2 2 399 6 THER ...

  • Friedrich HazardGard 60 Hz - page 15

    15 HAZARDGARD P ARTS LIST REF DESCRIPTION P ART NO# MODELS CODE CHASSIS P ARTS SH15L30-B SH20L30-B 8 HOLDER, THERMOST A T 61829800 1 1 999 1 1 KNOB, CONTROL 61493915 1 1 761 17 DECORA TIVE P ANEL 61822662 1 1 760 22 F AN BLADE, COND. 60542003 1 710 22 F AN BLADE, COND. 60542004 1 710 23 BLOWER WHEEL, EV AP . 60610616 1 700 23 BLOWER WHEEL, EV AP . ...

  • Friedrich HazardGard 60 Hz - page 16

    HG-SVC-PRTS-07 (3-07) FRIEDRICH AIR CONDITIONING CO. Post Of fi ce Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4480 www .friedrich.com Printed in the U.S.A. Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.fri edri ch. ...

Производитель Friedrich Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Friedrich HazardGard 60 Hz мы можем разделить на несколько групп. Это в частности:
- технические чертежи Friedrich
- инструкции обслуживания HazardGard 60 Hz
- паспорта изделия Friedrich
- информационные брошюры
- энергетические этикетки Friedrich HazardGard 60 Hz
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Friedrich HazardGard 60 Hz.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Friedrich HazardGard 60 Hz, инструкции обслуживания, короткие инструкции или инструкции пользователя Friedrich HazardGard 60 Hz. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Friedrich HazardGard 60 Hz.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Friedrich HazardGard 60 Hz, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Friedrich HazardGard 60 Hz пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Friedrich HazardGard 60 Hz.

Полная инструкция обслуживания Friedrich, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Friedrich HazardGard 60 Hz - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Friedrich HazardGard 60 Hz, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Friedrich HazardGard 60 Hz, которое найдем в данном документе
3. Советы по использованию основных функций устройства Friedrich HazardGard 60 Hz - которые должны облегчить нам первые шаги во время использования Friedrich HazardGard 60 Hz
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Friedrich HazardGard 60 Hz
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Friedrich HazardGard 60 Hz в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Friedrich HazardGard 60 Hz?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Friedrich HazardGard 60 Hz, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Friedrich HazardGard 60 Hz со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)