    Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.com F21287A EN (071514) Professional Indoor and Outdoor Hoods Installation Guide ...

  • Viking F21287A EN - page 2

    3 NOTE: If installing hood with warming shelf panel, install warming shelf panel first. IMPORTANT – PLEASE READ AND FOLLOW • Before beginning, please read these instructions completely and carefully. • Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. • Please observe all local and n ...

  • Viking F21287A EN - page 3

    5 4 21” (53.3 cm) A 10” (25.4 cm) 12 ” (30.5 cm) A (Hood width) 30”W . 29-7/8“ (76.2 cm) 36”W . 35-7/8” (91.1 cm) 5” (12.7 cm) 21” (53.3 cm) A 12 ” (30.5 cm) A (Hood width) 30”W . 29-7/8“ (76.2 cm) 36”W . 35-7/8” (91.1 cm) 5” (12.7 cm) 12 ” (30.5 cm) (VWH 10” H./12”H. Wall Hoods w/Standard Ventilator 30”, & ...

  • Viking F21287A EN - page 4

    6 7 * NOTE: When installing with a 24” high-shelf, the 27” (68.6 cm) max. dimensions must be used. 24”min. (61.0 cm) to 27”max.* (68.6 cm) 60”min. (152.4 cm) to 63”max. (160.0 cm) 36” (91.4 cm) A B C D 18” (4.6 cm) 3-7/8” (9.8 cm) 3-4” (1.9 cm) 7” (17.8 cm) dia. duct location Electrical hookup 1/2” (1.3 cm) 4” (10.2 cm) 3- ...

  • Viking F21287A EN - page 5

    9 8 24” (61.0 cm) A 18” (45.7 cm) 12” (30.5 cm) 6” (15.2 cm) A (Hood width) 30”W . 29-7/8“ (76.2 cm) 36”W . 35-7/8” (91.1 cm) 42”W . 41-7/8” (106.4 cm) 48“W . 47-7/8” (121.6 cm) 60”W . 59-7/8” (152.1 cm) (VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”) * A 1,200 CFM interior- or exterior-power ...

  • Viking F21287A EN - page 6

    11 10 10” (25.4 cm) dia. duct location B A 30”W . 14-15/16” (37.9 cm) 36”W . 17-15/16” (45.6 cm) 42”W . 20-15/16” (53.2 cm) 48”W . 23-15/16” (60.8 cm) 60”W . 29-15/16” (76.0 cm) A 5-1/2” (14.0 cm) B 30”W . 29-7/8” (75.9 cm) 36”W . 35-7/8” (91.1 cm) 42”W . 41-7/8” (106.4 cm) 48”W . 47-7/8” (121.6 cm) 60”W . ...

  • Viking F21287A EN - page 7

    13 12 27” (68.6 cm) A 18” (45.7 cm) 12” (30.5 cm) 6” (15.2 cm) A (Hood width) 36”W . 35-7/8” (91.1 cm) 48“W . 47-7/8” (121.6 cm) 60”W . 59-7/8” (152.1 cm) Seal joints with silicone. Provided on “T” Series only . (VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”) * A 1,200 CFM interior- or exterior-power ventilator s ...

  • Viking F21287A EN - page 8

    15 14 24” (61.0 cm) B A 18” (45.7 cm) 12” (30.5 cm) to 24” (61.0 cm) 6” (15.2 cm) A (Duct width) 30”W . 12“ (30.5 cm) 36”W . 12“ (30.5 cm) 42”W . 12“ (30.5 cm) 48“W . 18“ (45.7 cm) 60”W . 24“ (61.0 cm) 66”W . 24“ (61.0 cm) B (Hood width) 30”W . 29-7/8“ (76.2 cm) 36”W . 35-7/8” (91.1 cm) 42”W . 41-7/8” ( ...

  • Viking F21287A EN - page 9

    16 17 A 48”W . 23-15/16” (60.8 cm) 60”W . 29-15/16” (76.0 cm) 66”W . 32-15/16” (83.7 cm) C 48”W . 18” (45.7 cm) 60”W . 24” (61.0 cm) 66”W . 24” (61.0 cm) 10” (25.4 cm) dia. duct location 6” (15.2 cm) 1-1/2” (3.8 cm) 1-1/2” (3.8 cm) A B C 120 V power supply B 48”W . 47-7/8” (121.6 cm) 60”W . 59-7/8” (152.1 cm) ...

  • Viking F21287A EN - page 10

    19 18 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft (15.2 m). ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m). NOTE: Maximum amp rating for hoods includes recommended ventilator kit rat ...

  • Viking F21287A EN - page 11

    21 20 A 54”W . 26-15/16” (68.4 cm) 66”W . 32-15/16” (83.7 cm) C 54”W . 18” (45.7 cm) 66”W . 24” (61.0 cm) 1-1/8” (2.9 cm) 1-1/8” (2.9 cm) 10” (25.4 cm) dia. duct location B A C 6” (15.2 cm) 120 V power supply B 54”W . 53-7/8” (136.8 cm) 66”W . 65-7/8” (167.3 cm) 7” (17.8 cm) dia. duct location 12” (30.5 cm) 120 V ...

  • Viking F21287A EN - page 12

    23 22 (VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”) 21-7/16” (54.5 cm) A* *For best results, center the unit over the burners of the cooking product (front to back; right to left). Wall Hoods Description A (Hood Width) 36” W. 33-7/16” (84.9 cm) 42” W. 39-7/16” (100.2 cm) 48” W. 45-7/16” (115.4 cm) 60” W. 57-7 ...

  • Viking F21287A EN - page 13

    25 1-1/2” (3.81 cm) 1” (2.54 cm) 21-5/16” (54.1 cm) 21-7/8” (55.8 cm) 6” (15.2 cm) 4 1 o 17-1/4” (43.8 cm) 7/8” (2.2 cm) 1-1/2” (3.8 cm) 17-1/4” (43.8 cm) 11-1/2” (29.2 cm) 21-5/16” (54.1 cm) 6” (15.2 cm) 21-7/8” (55.8 cm) 4 1 o 9/16” (1.4 cm) D 10” (25.4 cm) dia. duct location 5-1/2” (14.0 cm) D 9/16” (1.4 cm) 7? ...

  • Viking F21287A EN - page 14

    27 26 9/16” (1.4 cm) D C 10” (25.4 cm) dia. duct location 5-1/2” (14.0 cm) 1200 or 1500 CFM Exterior or In-Line Ventilator Installation 48”, 60” W. Models 9/16” (1.4 cm) C 10” (25.4 cm) dia. duct location 5-1/2” (14.0 cm) D 1200 CFM Interior Ventilator Installation 36”, 42”, 48”, 60” W. Models C 36” W. 34-1/4” (87.0 cm) ...

  • Viking F21287A EN - page 15

    29 CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting screws, if necessary. Connect black to black, white to white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring to be correct when wir ...

  • Viking F21287A EN - page 16

    31 CAUTION: Secure vent hood. Make sure mounting screws are secured into framing. Use additional mounting screws and wall anchors, if necessary. 7 5/16” n ut drive r 5 Remove electrical box cover. 1 6 2 Flip hood over. Insert 6” of electrical wiring through the top of vent hood and secure. Refer to local codes. 3 4 Attach with screws and lock w ...

  • Viking F21287A EN - page 17

    33 1-13/1 6 ” (4.6 cm ) 1-1/2”x 3/4” (3.8 cm) x (1.9 cm) wood strip 1 5/16” nut driver Slot for wood strip 2 5/16” nut driver Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (provided locally) to wall using screws provided. Use additional mounting screws to secure hood to wood strip. 3 5/1 ...

  • Viking F21287A EN - page 18

    35 3 4 2 Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place and remove tape. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. 1 2 Measure distance from ceiling to canopy. Tape to avoid scratching. 34 1 ...

  • Viking F21287A EN - page 19

    37 4 5/16” nut driver Attach canopy to duct cover/soffit. Seal top of hood to duct with aluminum tape. 3 T o install ventillation kit refer to ventillation kit installation instructions. Run duct work down to bottom edge of duct cover/soffit and secure in place. Make sure the duct does not stick down past the cover. Slide filter front over front ...

  • Viking F21287A EN - page 20

    38 39 If service is required, call your dealer or authorized service agency. The name of the authorized service agency can be obtained from the dealer or distributor in your area. Have the following information readily available. • Model number • Serial number • Date purchased • Name of dealer from whom purchased Clearly describe the proble ...

Производитель Viking Категория Ventilation Hood

Документы, которые мы получаем от производителя устройства Viking F21287A EN мы можем разделить на несколько групп. Это в частности:
- технические чертежи Viking
- инструкции обслуживания F21287A EN
- паспорта изделия Viking
- информационные брошюры
- энергетические этикетки Viking F21287A EN
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Viking F21287A EN.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Viking F21287A EN, инструкции обслуживания, короткие инструкции или инструкции пользователя Viking F21287A EN. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Viking F21287A EN.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Viking F21287A EN, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Viking F21287A EN пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Viking F21287A EN.

Полная инструкция обслуживания Viking, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Viking F21287A EN - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Viking F21287A EN, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Viking F21287A EN, которое найдем в данном документе
3. Советы по использованию основных функций устройства Viking F21287A EN - которые должны облегчить нам первые шаги во время использования Viking F21287A EN
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Viking F21287A EN
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Viking F21287A EN в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Viking F21287A EN?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Viking F21287A EN, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Viking F21287A EN со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)