Инструкция обслуживания Lucent Technologies EST-48

20 страниц 0.63 mb
Скачать

Перейти на страницу of 20

Summary
  • Lucent Technologies EST-48 - page 1

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 48" Wood Burning Fireplaces P/N 850,006M REV. C 04/2004 EST -48 EST -48-H MODELS WH Report No. 629-915173 EST A TE SERIES This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and under- stand these instructions b ...

  • Lucent Technologies EST-48 - page 2

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction ..................................... page 3 Clearances/Height Requirements ..... page 3 Chimney System .. ...

  • Lucent Technologies EST-48 - page 3

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • millboard • dry wall • plywood • etc. PRECAUTIONS Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended tha ...

  • Lucent Technologies EST-48 - page 4

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT. INSULATION OR VAPOR BARRIERS, IF USED, MUST FIRST BE COVERED WITH GYPSUM BOARD, PLYWOOD, PARTICLE BOARD OR OTHER MATERIAL TO ASSURE INSULATION AND VAPOR BARRIERS REMAIN IN PLACE. Figure 2 Chimney Height The tota ...

  • Lucent Technologies EST-48 - page 5

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Figure 5 Figure 7 Figure 6 The fireplace may be positioned and then the framing built around it, or the framing may be constructed and the fireplace positioned into the opening. Usually, no special floor support is needed for the fireplace, however, to be certain: 1. Estimate the total weight of th ...

  • Lucent Technologies EST-48 - page 6

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 Figure 10 IMPORTANT: UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS ( FIGURE 10 ) BE REMOVED OR MODIFIED, NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPACERS. THE HEADER MAY BE IN DIRECT CONTACT WITH THE TOP SPACERS BUT MAY NOT BE SUPPORTED BY THEM. Note: The fra ...

  • Lucent Technologies EST-48 - page 7

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 FRAMING SPECIFICATIONS Figure 11 Figure 12 Framing Dimensions for Ceiling Flue Type A B FTF13 Vertical 19" 19" (483 mm) (483 mm) FTF13 19" 29" Offset 30 ° (483 mm) (737 mm) Figure 13 A Outside Chase G C J Back Wall of Chase/Enclosure Including Finising Materials if any Rough Fr ...

  • Lucent Technologies EST-48 - page 8

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Firestop Spacer Room Above Firestop Spacer Attic Above F10FS30-2 Firestop Spacer FTF10-S4 Stabilizer 2" Min. Air Space 30 ° Firestop And Attic Above 10' Max. Attic Space 2" Min. Air Space F10FS30-2 Firestop Spacer FTF10-S4 Stabilizer 30 ° Firestop And Room Above 10' Max. Room ...

  • Lucent Technologies EST-48 - page 9

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Step 4. Note: Chimney sections are constructed with a unique locking tab design, which en- sures an immediate, tight assembly between sections. Plan your chimney requirements care- fully before assembly as chimney is difficult to disassemble after installation. If disassembled, the tabs might becom ...

  • Lucent Technologies EST-48 - page 10

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Locking Band Mastic Figure 30 Step 9. Security Chimneys locking bands, Model FLB, may be required if the chimney extends too high above the roof flashing. As a general rule, if the chimney extends more than 6' above the roof flashing, the use of locking bands is advisable to strengthen the ch ...

  • Lucent Technologies EST-48 - page 11

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 A ¹⁄₈ " diameter hole must be drilled in the chimney joint using a ¹⁄₈ " diameter drill. Hole should be drilled in center of joint overlap ( see Figure 38 ). Be sure to drill only through the outer chimney casting. Do not puncture the inner flue. Maximum offset of chimney syste ...

  • Lucent Technologies EST-48 - page 12

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 FTF13 VERTICAL ELEVATION CHART 11 0 11 1 0 0 279 0.28 17 1 5 0 1 0 432 0.43 21 ¹⁄₄ 19 ¹⁄₄ 2 0 0 540 0.54 27 ¹⁄₄ 23 ¹⁄₄ 1 1 0 692 0.69 33 ¹⁄₄ 29 ¹⁄₄ 0 2 0 845 0.85 35 2 11 0 0 1 889 0.89 37 ¹⁄₄ 31 ¹⁄₄ 2 1 0 946 0.95 43 ¹⁄₄ 37 ¹⁄₄ 1 2 0 1099 1.10 51 ...

  • Lucent Technologies EST-48 - page 13

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 Figure 36 A 1 C 1 B 1 B 2 C 2 A 2 A 1 C 1 B 1 B 2 C 2 A 2 Figure 37 Chimney Section Joints No. 8 x 1/2" SMS Screws Required At Every Joint Past 6' No Screws Required In Joints For First 6' of Offset 4' 6' FTF13 OFFSET ELEVATION CHART A B FTF13-ES30 Number of FTF13 A B Offs ...

  • Lucent Technologies EST-48 - page 14

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Step 3. Center outer-locking section over outer chimney pipe. Push down until locking joint has firmly engaged. Step 4. Pull up slightly on return elbow to ensure locking joint has firmly engaged. Step 5. Secure support straps to framing members by nailing under tension in sheer ( Figure 40 ). Ret ...

  • Lucent Technologies EST-48 - page 15

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 OPTIONAL EQUIPMENT CONSIDERATIONS Gas Line Connection The EST-48 has been listed to accept a ¹⁄₂ " gas line for an approved gas appliance. Always have the appliance installed in accordance with all local building codes. CAUTION: ALL GAS CONNECTIONS SHOULD ONLY BE PERFORMED BY A QUALIFIED ...

  • Lucent Technologies EST-48 - page 16

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 45 Figure 44 A B D C C Hearth Extensions and Wall Shields A hearth extension must be installed with all fireplaces. It is to protect the floor in front of the fireplace from both radiant heat and sparks. For Model EST-48, the hearth extension must ex- tend 12" beyond both sides and mus ...

  • Lucent Technologies EST-48 - page 17

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 47 FINISH TO YOUR TASTE There are a wide variety of “ finished looks ” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like stone, tile, brick, etc., may overlap the black front facing. Do n ...

  • Lucent Technologies EST-48 - page 18

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 63L19 FTF13-12 63L20 FTF13-18 Chimney Section 63L21 FTF13-36 63L40 F10F6 Flashing 63L41 F10F12 Round Termination 63L44 FTF13-CTD Firestop Spacer (Flat) 63L36 F10FS-2 INSTALLATION COMPONENTS Storm Collar 63L59 FSC Chase Termination (Square) 63L50 FTF13-CT1 ...

  • Lucent Technologies EST-48 - page 19

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 ...

  • Lucent Technologies EST-48 - page 20

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2001 by LENNOX HEARTH PRODUCT ...

Производитель Lucent Technologies Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Lucent Technologies EST-48 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lucent Technologies
- инструкции обслуживания EST-48
- паспорта изделия Lucent Technologies
- информационные брошюры
- энергетические этикетки Lucent Technologies EST-48
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lucent Technologies EST-48.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lucent Technologies EST-48, инструкции обслуживания, короткие инструкции или инструкции пользователя Lucent Technologies EST-48. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lucent Technologies EST-48.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lucent Technologies EST-48, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lucent Technologies EST-48 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lucent Technologies EST-48.

Полная инструкция обслуживания Lucent Technologies, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lucent Technologies EST-48 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lucent Technologies EST-48, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lucent Technologies EST-48, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lucent Technologies EST-48 - которые должны облегчить нам первые шаги во время использования Lucent Technologies EST-48
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lucent Technologies EST-48
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lucent Technologies EST-48 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lucent Technologies EST-48?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lucent Technologies EST-48, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lucent Technologies EST-48 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)