    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 45" Wood Burning Fireplaces P/N 850,045M REV. N/C 01/2007 TM-4500 MODEL RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WH Report No. J20054576-231 This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and under- s ...

  • Lucent Technologies TM-4500 - page 2

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction ..................................... page 3 Chimney/Mantel Clearances and Height Requirements ........... ...

  • Lucent Technologies TM-4500 - page 3

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • dry wall • etc. • plywood PRECAUTIONS Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installe ...

  • Lucent Technologies TM-4500 - page 4

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 Figure 2 LOCATION OF FIREPLACE Carefully select the proper location for heat circulation, aesthetics, chimney obstructions and clearance to side wall(s). With proper pre- planning, a slight adjustment of a few inches can save considerable time and expense later during construction and assembly. Cha ...

  • Lucent Technologies TM-4500 - page 5

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 DO NOT permanently place furniture or other items such as decorative pillows within 60" of the fireplace front face. ASSEMBLY STEPS Note: The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence. 1. Position ...

  • Lucent Technologies TM-4500 - page 6

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 Step 3. Refer to fireplace drawings and specifi- cations on pages 6 and 7 for framing dimensions and details. Frame appliance enclosure as illus- trated in Figures 12 through 15 on page 7. IMPORTANT: UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS ( SEE FIGURE 11 ) BE REMOVED OR MODIFIED, NOR ...

  • Lucent Technologies TM-4500 - page 7

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Note: The framed depth, 28 ¹ ⁵ ⁄ ₁ ₆ " (735 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the framed depth must be measured from the drywall sur- face. It is important that this dime ...

  • Lucent Technologies TM-4500 - page 8

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 5. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face. Use 8d nails or equivalent ( Figure 18 ). Figure 18 Note: The nailing tabs and the area directly behind the nailing tabs are exempt from the clearances d ...

  • Lucent Technologies TM-4500 - page 9

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Step 4. Note: Chimney sections are constructed with a unique locking tab design, which en- sures an immediate, tight assembly between sections. Plan your chimney requirements care- fully before assembly as chimney is difficult to disassemble after installation. If disassembled, the tabs might becom ...

  • Lucent Technologies TM-4500 - page 10

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Locking Band Waterproof Caulk Roof Ridge 120 ° Step 8. The standard Security Chimneys FTF10 roof flashing assemblies include a storm collar. Slide the storm collar over outer chimney, rest on flashing spacers and align with top surface of flashing. Insert tab in slot, pull tight and bend tab back ...

  • Lucent Technologies TM-4500 - page 11

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 MULTIPLE TERMINATIONS If more than one termination is located in the same chase or within the same general proxim- ity, we suggest they should be separated in distance at least 24" (610 mm) horizontally from flue center to flue center and stacked or staggered vertically at least 18" (457 ...

  • Lucent Technologies TM-4500 - page 12

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 Figure 38 Figure 40 OFFSET CALCULATIONS Step 1. Use Offset Chart to determine amount of horizontal offset (A) and height (B) for various chimney section assemblies. Step 2. Use “Height of Chimney Only” column in The Vertical Elevation Chart to determine combinations of chimney used above retur ...

  • Lucent Technologies TM-4500 - page 13

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 397 ¹⁄₄ 33 1 ¹⁄₄ 20 1 1 403 ¹⁄₄ 33 7 ¹⁄₄ 11 1 1 411 34 3 0 0 12 421 ¹⁄₄ 35 1 ¹⁄₄ 10 1 2 427 ¹⁄₄ 35 7 ¹⁄₄ 01 1 2 431 ¹⁄₂ 35 11 ¹⁄₂ 20 1 2 437 ¹⁄₂ 36 5 ¹⁄₂ 11 1 2 445 ¹⁄₄ 37 1 ¹⁄₄ 00 1 3 455 ¹⁄₂ 37 11 ¹⁄₂ 10 1 3 461 ¹? ...

  • Lucent Technologies TM-4500 - page 14

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Return Elbow Figure 41 Note: The return elbow assembly performs the same function as a stabilizer. Consider this when determining the need for a stabilizer. Note: Do not apply excessive pressure to any subsequent chimney section following return elbow assembly when installing. Ensure that each sub ...

  • Lucent Technologies TM-4500 - page 15

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Outside combustion air ducting may be run upwards or vertically through framing and ceil- ing joists, with the hood installed through an outside wall and 3' (914 mm) below the termi- nation. Ducting may also be run downward through floor joists and under the home to a ventilated crawlspace no ...

  • Lucent Technologies TM-4500 - page 16

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 46 Note: Only non-combustible wall finishing materials are allowed on the front top of the unit, from the top edge of spacers down. See Figures 45 and 46 . Hearth Extensions and Wall Shields A hearth extension must be installed with all fireplaces. It is to protect the combustible floor in ...

  • Lucent Technologies TM-4500 - page 17

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Answer - The minimum required thickness of the Micore 160 is .417”, therefore round up to nearest standard thickness available which is 1/2”. ** If the hearth extension material(s) that is intended to be used is NOT listed on Table 1, the material can still be used if the material(s) is noncom ...

  • Lucent Technologies TM-4500 - page 18

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Locking Band 63L60 FLB Figure 50 Figure 49 FINISH TO YOUR TASTE There are a wide variety of “finished looks” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like stone, tile, brick, etc., may overl ...

  • Lucent Technologies TM-4500 - page 19

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 63L16 FTF10-12 63L17 FTF10-18 63L18 FTF10-36 62L94 FTF10-18C Chimney Section 62L95 FTF10-36C Storm Collar 63L59 FSC 63L40 F10F6 Flashing 63L41 F10F12 Firestop Spacer (Flat) 63L36 F10FS-2 Chase Termination (Square) 63L52 FTF10-CT2RS INSTALLATION COMPONENTS Firestop Spacer (30 ° ) 63L37 F10FS30-2 R ...

  • Lucent Technologies TM-4500 - page 20

    NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2007 by Lennox Hearth Products P/N ...

Производитель Lucent Technologies Категория Indoor Fireplace

Документы, которые мы получаем от производителя устройства Lucent Technologies TM-4500 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Lucent Technologies
- инструкции обслуживания TM-4500
- паспорта изделия Lucent Technologies
- информационные брошюры
- энергетические этикетки Lucent Technologies TM-4500
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Lucent Technologies TM-4500.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Lucent Technologies TM-4500, инструкции обслуживания, короткие инструкции или инструкции пользователя Lucent Technologies TM-4500. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Lucent Technologies TM-4500.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Lucent Technologies TM-4500, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Lucent Technologies TM-4500 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Lucent Technologies TM-4500.

Полная инструкция обслуживания Lucent Technologies, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Lucent Technologies TM-4500 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Lucent Technologies TM-4500, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Lucent Technologies TM-4500, которое найдем в данном документе
3. Советы по использованию основных функций устройства Lucent Technologies TM-4500 - которые должны облегчить нам первые шаги во время использования Lucent Technologies TM-4500
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Lucent Technologies TM-4500
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Lucent Technologies TM-4500 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Lucent Technologies TM-4500?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Lucent Technologies TM-4500, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Lucent Technologies TM-4500 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)