Bedienungsanleitung Trane TDH2C100A9V4VA

30 Seiten 1.74 mb
Download

Zur Seite of 30

Summary
  • Trane TDH2C100A9V4VA - page 1

    XV 95 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A PUB. NO . 22-1814-08 Upflo w/ Horizontal Left, Do wnflo w/ Horizontal Right V ariab le Speed T w o Sta g e Condensing Gas-Fired Furnace UPFLO W *UH-A9V -V UPFLO W/HORIZONT AL *DH-A9V -V DO WNFLO W DO WNFLO W/HORIZONT AL Direct V ent with V ariabl ...

  • Trane TDH2C100A9V4VA - page 2

    2 Pub . No . 22-1814-08 General Features © 2012 T rane All Rights Reser ved NA TURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Associa - tio n for both natur al and L.P . gas. Limit setting and rating data were estab lished and approv ed under standard rating conditions using American National Standards Institut ...

  • Trane TDH2C100A9V4VA - page 3

    3 Pub . No . 22-1814-08 Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6-8 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A TDH2B060A9V3V A TDH2B080A9V3V A TDH2B080A9V4V A TDH2C100A9V4V A TDH2D120A9V5V A P erf ormance Data 9-19 V enting T abl ...

  • Trane TDH2C100A9V4VA - page 4

    4 Pub . No . 22-1814-08 XV 95 ST AND ARD EQUIPMENT Features and Benefits • Lite P or t ™ e xtended system diag - nostics • Stored f ault code history in micro pro - cessor nonv ocatile memor y • Cleanable high velocity lters (upo w only) • Hinged blow er door * • P erfect t door latches* • Insulated blower door* • Gasketed ...

  • Trane TDH2C100A9V4VA - page 5

    5 Pub . No . 22-1814-08 Features and Benefits XV 95 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... T A YST A T241 [ ] Thermostat, Media Programmable 2-Stage Heating ............................................................. ...

  • Trane TDH2C100A9V4VA - page 6

    6 Pub . No . 22-1814-08 General Data 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1 ...

  • Trane TDH2C100A9V4VA - page 7

    7 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TDH2C100A9V4VA - page 8

    8 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TDH2C100A9V4VA - page 9

    9 Pub . No . 22-1814-08 *UH2B060A9V3V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 1.5 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 575 65 575 90 575 125 550 155 - NORMAL ( ...

  • Trane TDH2C100A9V4VA - page 10

    10 Pub . No . 22-1814-08 *UH2B080A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 105 ...

  • Trane TDH2C100A9V4VA - page 11

    11 Pub . No . 22-1814-08 *UH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 105 ...

  • Trane TDH2C100A9V4VA - page 12

    12 Pub . No . 22-1814-08 *UH2C100A9V4V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.5 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 808 75 824 125 840 170 835 210 830 250 ...

  • Trane TDH2C100A9V4VA - page 13

    13 Pub . No . 22-1814-08 *UH2C100A9V5V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 62,855 96,700 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 873 64 100 ...

  • Trane TDH2C100A9V4VA - page 14

    14 Pub . No . 22-1814-08 *UH2D120A9V5V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 3.5 LOW (350 CFM/T ON) OFF ON OFF ON CFM W A TTS 1210 220 1210 270 1220 325 1230 400 12 ...

  • Trane TDH2C100A9V4VA - page 15

    15 Pub . No . 22-1814-08 *DH2B060A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 37,440 57,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 600 56 ...

  • Trane TDH2C100A9V4VA - page 16

    16 Pub . No . 22-1814-08 *DH2B080A9V3V - FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.0 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 700 95 700 105 700 115 680 200 670 23 ...

  • Trane TDH2C100A9V4VA - page 17

    17 Pub . No . 22-1814-08 *DH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 49,400 76,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 ...

  • Trane TDH2C100A9V4VA - page 18

    18 Pub . No . 22-1814-08 *DH2C100A9V4V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 62,400 96,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 923 6 ...

  • Trane TDH2C100A9V4VA - page 19

    19 Pub . No . 22-1814-08 *DH2D120A9V5V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 74,880 115,200 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 8 SW 7 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1025 ...

  • Trane TDH2C100A9V4VA - page 20

    20 Pub . No . 22-1814-08 Maxim um V ent Length T able VENT LENGTH T ABLE AL TITUDE MAXIMUM T OT AL EQUIV ALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NO TES) 0-7,000 F eet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3V A 200 200 200 *UH/DH2B080A9V3V A *UH/DH2B080A9V4V A 50 120 200 *UH/DH2C100A9V4V A *UH2C100A9V5V A Not Allowed 60 2 ...

  • Trane TDH2C100A9V4VA - page 21

    21 Pub . No . 22-1814-08 Electrical Data *UH2 WIRING DIA GRAM F rom drawing D344303 ...

  • Trane TDH2C100A9V4VA - page 22

    22 Pub . No . 22-1814-08 Electrical Data *UH2 SCHEMA TIC DIA GRAM F rom drawing D344303 ...

  • Trane TDH2C100A9V4VA - page 23

    23 Pub . No . 22-1814-08 *DH2 WIRING DIA GRAM Electrical Data F rom drawing D344304 ...

  • Trane TDH2C100A9V4VA - page 24

    24 Pub . No . 22-1814-08 *DH2 SCHEMA TIC DIA GRAM Electrical Data F rom drawing D344304 ...

  • Trane TDH2C100A9V4VA - page 25

    25 Pub . No . 22-1814-08 FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING ONL Y FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING ONL Y Field Wiring ...

  • Trane TDH2C100A9V4VA - page 26

    26 Pub . No . 22-1814-08 Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING/ SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) ...

  • Trane TDH2C100A9V4VA - page 27

    27 Pub . No . 22-1814-08 Dimensions *UH2 UPFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) ...

  • Trane TDH2C100A9V4VA - page 28

    28 Pub . No . 22-1814-08 *DH2 DO WNFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) Dimensions ...

  • Trane TDH2C100A9V4VA - page 29

    29 Pub . No . 22-1814-08 Notes ...

  • Trane TDH2C100A9V4VA - page 30

    T rane has a policy of continuous product and product data improv ement and i t reser ves the right to change design and specifications without notice. T rane 6200 T roup Highwa y T yler, TX 75707 www .trane.com ...

Produzent Trane Kategorie Furnace

Dokumente, die wir vom Produzenten des Geräts Trane TDH2C100A9V4VA erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Trane
- Bedienungsanleitungen TDH2C100A9V4VA
- Produktkarten Trane
- Informationsbroschüren
- oder Energieetiketten Trane TDH2C100A9V4VA
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Trane TDH2C100A9V4VA.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Trane TDH2C100A9V4VA, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Trane TDH2C100A9V4VA. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Trane TDH2C100A9V4VA ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Trane TDH2C100A9V4VA, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Trane TDH2C100A9V4VA hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Trane TDH2C100A9V4VA verständlich ist.

Eine gänzliche Bedienungsanleitung von Trane sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Trane TDH2C100A9V4VA bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Trane TDH2C100A9V4VA befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Trane TDH2C100A9V4VA, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Trane TDH2C100A9V4VA - die uns die ersten Schritte während der Nutzung von Trane TDH2C100A9V4VA erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Trane TDH2C100A9V4VA hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Trane TDH2C100A9V4VA im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Trane TDH2C100A9V4VA?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Trane TDH2C100A9V4VA nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Trane TDH2C100A9V4VA hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)