    XV 95 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A PUB. NO . 22-1814-08 Upflo w/ Horizontal Left, Do wnflo w/ Horizontal Right V ariab le Speed T w o Sta g e Condensing Gas-Fired Furnace UPFLO W *UH-A9V -V UPFLO W/HORIZONT AL *DH-A9V -V DO WNFLO W DO WNFLO W/HORIZONT AL Direct V ent with V ariabl ...

  • Trane TDH2C100A9V4VA - page 2

    2 Pub . No . 22-1814-08 General Features © 2012 T rane All Rights Reser ved NA TURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Associa - tio n for both natur al and L.P . gas. Limit setting and rating data were estab lished and approv ed under standard rating conditions using American National Standards Institut ...

  • Trane TDH2C100A9V4VA - page 3

    3 Pub . No . 22-1814-08 Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6-8 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A TDH2B060A9V3V A TDH2B080A9V3V A TDH2B080A9V4V A TDH2C100A9V4V A TDH2D120A9V5V A P erf ormance Data 9-19 V enting T abl ...

  • Trane TDH2C100A9V4VA - page 4

    4 Pub . No . 22-1814-08 XV 95 ST AND ARD EQUIPMENT Features and Benefits • Lite P or t ™ e xtended system diag - nostics • Stored f ault code history in micro pro - cessor nonv ocatile memor y • Cleanable high velocity lters (upo w only) • Hinged blow er door * • P erfect t door latches* • Insulated blower door* • Gasketed ...

  • Trane TDH2C100A9V4VA - page 5

    5 Pub . No . 22-1814-08 Features and Benefits XV 95 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... T A YST A T241 [ ] Thermostat, Media Programmable 2-Stage Heating ............................................................. ...

  • Trane TDH2C100A9V4VA - page 6

    6 Pub . No . 22-1814-08 General Data 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1 ...

  • Trane TDH2C100A9V4VA - page 7

    7 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TDH2C100A9V4VA - page 8

    8 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TDH2C100A9V4VA - page 9

    9 Pub . No . 22-1814-08 *UH2B060A9V3V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 1.5 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 575 65 575 90 575 125 550 155 - NORMAL ( ...

  • Trane TDH2C100A9V4VA - page 10

    10 Pub . No . 22-1814-08 *UH2B080A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 105 ...

  • Trane TDH2C100A9V4VA - page 11

    11 Pub . No . 22-1814-08 *UH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 105 ...

  • Trane TDH2C100A9V4VA - page 12

    12 Pub . No . 22-1814-08 *UH2C100A9V4V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.5 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 808 75 824 125 840 170 835 210 830 250 ...

  • Trane TDH2C100A9V4VA - page 13

    13 Pub . No . 22-1814-08 *UH2C100A9V5V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 62,855 96,700 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 873 64 100 ...

  • Trane TDH2C100A9V4VA - page 14

    14 Pub . No . 22-1814-08 *UH2D120A9V5V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 3.5 LOW (350 CFM/T ON) OFF ON OFF ON CFM W A TTS 1210 220 1210 270 1220 325 1230 400 12 ...

  • Trane TDH2C100A9V4VA - page 15

    15 Pub . No . 22-1814-08 *DH2B060A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 37,440 57,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 600 56 ...

  • Trane TDH2C100A9V4VA - page 16

    16 Pub . No . 22-1814-08 *DH2B080A9V3V - FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.0 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 700 95 700 105 700 115 680 200 670 23 ...

  • Trane TDH2C100A9V4VA - page 17

    17 Pub . No . 22-1814-08 *DH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 49,400 76,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 ...

  • Trane TDH2C100A9V4VA - page 18

    18 Pub . No . 22-1814-08 *DH2C100A9V4V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 62,400 96,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 923 6 ...

  • Trane TDH2C100A9V4VA - page 19

    19 Pub . No . 22-1814-08 *DH2D120A9V5V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 74,880 115,200 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 8 SW 7 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1025 ...

  • Trane TDH2C100A9V4VA - page 20

    20 Pub . No . 22-1814-08 Maxim um V ent Length T able VENT LENGTH T ABLE AL TITUDE MAXIMUM T OT AL EQUIV ALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NO TES) 0-7,000 F eet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3V A 200 200 200 *UH/DH2B080A9V3V A *UH/DH2B080A9V4V A 50 120 200 *UH/DH2C100A9V4V A *UH2C100A9V5V A Not Allowed 60 2 ...

  • Trane TDH2C100A9V4VA - page 21

    21 Pub . No . 22-1814-08 Electrical Data *UH2 WIRING DIA GRAM F rom drawing D344303 ...

  • Trane TDH2C100A9V4VA - page 22

    22 Pub . No . 22-1814-08 Electrical Data *UH2 SCHEMA TIC DIA GRAM F rom drawing D344303 ...

  • Trane TDH2C100A9V4VA - page 23

    23 Pub . No . 22-1814-08 *DH2 WIRING DIA GRAM Electrical Data F rom drawing D344304 ...

  • Trane TDH2C100A9V4VA - page 24

    24 Pub . No . 22-1814-08 *DH2 SCHEMA TIC DIA GRAM Electrical Data F rom drawing D344304 ...

  • Trane TDH2C100A9V4VA - page 25

    25 Pub . No . 22-1814-08 FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING ONL Y FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING ONL Y Field Wiring ...

  • Trane TDH2C100A9V4VA - page 26

    26 Pub . No . 22-1814-08 Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING/ SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) ...

  • Trane TDH2C100A9V4VA - page 27

    27 Pub . No . 22-1814-08 Dimensions *UH2 UPFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) ...

  • Trane TDH2C100A9V4VA - page 28

    28 Pub . No . 22-1814-08 *DH2 DO WNFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) Dimensions ...

  • Trane TDH2C100A9V4VA - page 29

    29 Pub . No . 22-1814-08 Notes ...

  • Trane TDH2C100A9V4VA - page 30

    T rane has a policy of continuous product and product data improv ement and i t reser ves the right to change design and specifications without notice. T rane 6200 T roup Highwa y T yler, TX 75707 www .trane.com ...

Fabricante Trane Categoría Furnace

Los documentos del dispositivo Trane TDH2C100A9V4VA que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Trane
- manuales de instrucciones TDH2C100A9V4VA
- hojas de producto Trane
- folletos informativos
- o etiquetas energéticas Trane TDH2C100A9V4VA
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Trane TDH2C100A9V4VA.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Trane TDH2C100A9V4VA, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Trane TDH2C100A9V4VA. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Trane TDH2C100A9V4VA.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Trane TDH2C100A9V4VA, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Trane TDH2C100A9V4VA. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Trane TDH2C100A9V4VA.

El manual de instrucciones completo de Trane debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Trane TDH2C100A9V4VA - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Trane TDH2C100A9V4VA, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Trane TDH2C100A9V4VA que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Trane TDH2C100A9V4VA - que deben facilitarnos los primeros pasos durante el uso de Trane TDH2C100A9V4VA
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Trane TDH2C100A9V4VA
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Trane TDH2C100A9V4VA en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Trane TDH2C100A9V4VA?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Trane TDH2C100A9V4VA, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Trane TDH2C100A9V4VA probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)