    XV 95 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A PUB. NO . 22-1814-08 Upflo w/ Horizontal Left, Do wnflo w/ Horizontal Right V ariab le Speed T w o Sta g e Condensing Gas-Fired Furnace UPFLO W *UH-A9V -V UPFLO W/HORIZONT AL *DH-A9V -V DO WNFLO W DO WNFLO W/HORIZONT AL Direct V ent with V ariabl ...

  • Trane TDH2C100A9V4VA - page 2

    2 Pub . No . 22-1814-08 General Features © 2012 T rane All Rights Reser ved NA TURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Associa - tio n for both natur al and L.P . gas. Limit setting and rating data were estab lished and approv ed under standard rating conditions using American National Standards Institut ...

  • Trane TDH2C100A9V4VA - page 3

    3 Pub . No . 22-1814-08 Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6-8 TUH2B060A9V3V A TUH2B080A9V3V A TUH2B080A9V4V A TUH2C100A9V4V A TUH2C100A9V5V A TUH2D120A9V5V A TDH2B060A9V3V A TDH2B080A9V3V A TDH2B080A9V4V A TDH2C100A9V4V A TDH2D120A9V5V A P erf ormance Data 9-19 V enting T abl ...

  • Trane TDH2C100A9V4VA - page 4

    4 Pub . No . 22-1814-08 XV 95 ST AND ARD EQUIPMENT Features and Benefits • Lite P or t ™ e xtended system diag - nostics • Stored f ault code history in micro pro - cessor nonv ocatile memor y • Cleanable high velocity lters (upo w only) • Hinged blow er door * • P erfect t door latches* • Insulated blower door* • Gasketed ...

  • Trane TDH2C100A9V4VA - page 5

    5 Pub . No . 22-1814-08 Features and Benefits XV 95 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... T A YST A T241 [ ] Thermostat, Media Programmable 2-Stage Heating ............................................................. ...

  • Trane TDH2C100A9V4VA - page 6

    6 Pub . No . 22-1814-08 General Data 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1 ...

  • Trane TDH2C100A9V4VA - page 7

    7 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TDH2C100A9V4VA - page 8

    8 Pub . No . 22-1814-08 PRODUCT SPECIFICA TIONS 1 MODEL TYPE RA TINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE T emp. rise (Min.-Max.) °F . BLO WER DRIVE Diameter - Width (In.) No . Used Speeds (No .) CFM vs. in. w .g. Motor HP R.P .M. V olts / Ph / Hz COMBUSTION F AN - T ype ...

  • Trane TDH2C100A9V4VA - page 9

    9 Pub . No . 22-1814-08 *UH2B060A9V3V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 1.5 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 575 65 575 90 575 125 550 155 - NORMAL ( ...

  • Trane TDH2C100A9V4VA - page 10

    10 Pub . No . 22-1814-08 *UH2B080A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 105 ...

  • Trane TDH2C100A9V4VA - page 11

    11 Pub . No . 22-1814-08 *UH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 50,440 77,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 105 ...

  • Trane TDH2C100A9V4VA - page 12

    12 Pub . No . 22-1814-08 *UH2C100A9V4V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.5 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 808 75 824 125 840 170 835 210 830 250 ...

  • Trane TDH2C100A9V4VA - page 13

    13 Pub . No . 22-1814-08 *UH2C100A9V5V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st Stage Capacity = 2nd Stage Capacity = 62,855 96,700 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 873 64 100 ...

  • Trane TDH2C100A9V4VA - page 14

    14 Pub . No . 22-1814-08 *UH2D120A9V5V FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 3.5 LOW (350 CFM/T ON) OFF ON OFF ON CFM W A TTS 1210 220 1210 270 1220 325 1230 400 12 ...

  • Trane TDH2C100A9V4VA - page 15

    15 Pub . No . 22-1814-08 *DH2B060A9V3V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 37,440 57,600 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 600 56 ...

  • Trane TDH2C100A9V4VA - page 16

    16 Pub . No . 22-1814-08 *DH2B080A9V3V - FURNA CE COOLING AIRFLOW (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER OUTDOOR UNIT SIZE (T ONS) AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 2.0 LOW (350 CFM/T ON) ON ON OFF ON CFM W A TTS 700 95 700 105 700 115 680 200 670 23 ...

  • Trane TDH2C100A9V4VA - page 17

    17 Pub . No . 22-1814-08 *DH2B080A9V4V FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 49,400 76,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 800 56 ...

  • Trane TDH2C100A9V4VA - page 18

    18 Pub . No . 22-1814-08 *DH2C100A9V4V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 62,400 96,000 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 923 6 ...

  • Trane TDH2C100A9V4VA - page 19

    19 Pub . No . 22-1814-08 *DH2D120A9V5V - FURNA CE HEA TING AIRFLO W (CFM) AND PO WER (W A TTS) VS. EXTERNAL ST A TIC PRESSURE WITH FIL TER 1st ST AGE CAP ACITY = 2nd ST AGE CAP ACITY = 74,880 115,200 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL ST A TIC PRESSURE SW 8 SW 7 0.1 0.3 0.5 0.7 0.9 HEA TING 1ST ST AGE LOW ON ON CFM TEMP . RISE W A TTS 1025 ...

  • Trane TDH2C100A9V4VA - page 20

    20 Pub . No . 22-1814-08 Maxim um V ent Length T able VENT LENGTH T ABLE AL TITUDE MAXIMUM T OT AL EQUIV ALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NO TES) 0-7,000 F eet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3V A 200 200 200 *UH/DH2B080A9V3V A *UH/DH2B080A9V4V A 50 120 200 *UH/DH2C100A9V4V A *UH2C100A9V5V A Not Allowed 60 2 ...

  • Trane TDH2C100A9V4VA - page 21

    21 Pub . No . 22-1814-08 Electrical Data *UH2 WIRING DIA GRAM F rom drawing D344303 ...

  • Trane TDH2C100A9V4VA - page 22

    22 Pub . No . 22-1814-08 Electrical Data *UH2 SCHEMA TIC DIA GRAM F rom drawing D344303 ...

  • Trane TDH2C100A9V4VA - page 23

    23 Pub . No . 22-1814-08 *DH2 WIRING DIA GRAM Electrical Data F rom drawing D344304 ...

  • Trane TDH2C100A9V4VA - page 24

    24 Pub . No . 22-1814-08 *DH2 SCHEMA TIC DIA GRAM Electrical Data F rom drawing D344304 ...

  • Trane TDH2C100A9V4VA - page 25

    25 Pub . No . 22-1814-08 FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING ONL Y FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING ONL Y Field Wiring ...

  • Trane TDH2C100A9V4VA - page 26

    26 Pub . No . 22-1814-08 Field Wiring FIELD WIRING DIA GRAM FOR SINGLE ST A GE HEA TING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIA GRAM FOR TWO ST A GE HEA TING/ SINGLE ST A GE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) ...

  • Trane TDH2C100A9V4VA - page 27

    27 Pub . No . 22-1814-08 Dimensions *UH2 UPFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) ...

  • Trane TDH2C100A9V4VA - page 28

    28 Pub . No . 22-1814-08 *DH2 DO WNFLO W / HORIZONT AL OUTLINE DRA WING (ALL DIMENSIONS ARE IN INCHES) Dimensions ...

  • Trane TDH2C100A9V4VA - page 29

    29 Pub . No . 22-1814-08 Notes ...

  • Trane TDH2C100A9V4VA - page 30

    T rane has a policy of continuous product and product data improv ement and i t reser ves the right to change design and specifications without notice. T rane 6200 T roup Highwa y T yler, TX 75707 www .trane.com ...

Manufacturer Trane Category Furnace

Documents that we receive from a manufacturer of a Trane TDH2C100A9V4VA can be divided into several groups. They are, among others:
- Trane technical drawings
- TDH2C100A9V4VA manuals
- Trane product data sheets
- information booklets
- or energy labels Trane TDH2C100A9V4VA
All of them are important, but the most important information from the point of view of use of the device are in the user manual Trane TDH2C100A9V4VA.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Trane TDH2C100A9V4VA, service manual, brief instructions and user manuals Trane TDH2C100A9V4VA. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Trane TDH2C100A9V4VA.

A complete manual for the device Trane TDH2C100A9V4VA, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Trane TDH2C100A9V4VA by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Trane TDH2C100A9V4VA.

A complete Trane manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Trane TDH2C100A9V4VA - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Trane TDH2C100A9V4VA, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Trane TDH2C100A9V4VA, that we can find in the current document
3. Tips how to use the basic functions of the device Trane TDH2C100A9V4VA - which should help us in our first steps of using Trane TDH2C100A9V4VA
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Trane TDH2C100A9V4VA
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Trane TDH2C100A9V4VA in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Trane TDH2C100A9V4VA?

Use the form below

If you did not solve your problem by using a manual Trane TDH2C100A9V4VA, ask a question using the form below. If a user had a similar problem with Trane TDH2C100A9V4VA it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)