    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06 Copyright © 2001-2006 Campbell Scientific, Inc. ...

  • Campbell Manufacturing CS512 - page 2

    Warranty and Assistance The CS512 OXYGUARD TYPE III DISSOLVED OXYGEN PROBE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materi als and workmanship under norm al use and service for t welve (12) months from date of shipm ent unless specified otherwi se. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC. 's obligation ...

  • Campbell Manufacturing CS512 - page 3

    i CS512 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. General Information ..................................................... 1 2. Specifications .............................................................. 2 3. Optio ...

  • Campbell Manufacturing CS512 - page 4

    CS512 Table of Contents ii Examples 1. Sample Program using P1 .......................................................................... 5 2. Sample Program using P2 .......................................................................... 5 3. Sample Program using VoltSE .................................................................. 5 4. Sam ...

  • Campbell Manufacturing CS512 - page 5

    1 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe An accurate and reliable sensor is a critical element in any measurement system. The Oxyguard Stationary Probe meets these criteria for the measurement of dissolved oxygen. 1. General Information The Oxyguard Stationary Pro be is a galvanic prob e which produces a millivolt signal ...

  • Campbell Manufacturing CS512 - page 6

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 2 2. Specifications Principle of Measurem ent: Membrane covered galvanic oxygen probe Output Signal: 2.5 to 5 mV per m g 1 -1 Repeatability: Better than ± 0.2 mg/l calibration temperature equals measuring te mperature ± 5 ° C Output Impedance: ∼ 1 kohm Response Time: After equi ...

  • Campbell Manufacturing CS512 - page 7

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 3 3. Optional Probe Accessories PT4-L — Agitator for stagnant condi tions 18026 — DO electrolyte, 1 liter 18027 — Membrane kit , 10 mem branes 4. Optional Agitator The PT4 Agitator is a reli able and robust agitat or for use in conjunction with probes subjected to bio-fouling ...

  • Campbell Manufacturing CS512 - page 8

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 4 FIGURE 4-2. CS512 with PT4 Agitator Optional Repeat Cycle Timer for Agitators : Reciprocating act ion may be controlled by the opti onal solid state Repeat Cycle Tim er. It sends 12 VDC pulses to the agitator coil. The ON-time is 0.25 sec. The OFF-time is adjustab le from 3 to 12 ...

  • Campbell Manufacturing CS512 - page 9

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 5 7. Programming In the CR510, CR10X, and CR 23X datalogger, Instruction P1 or P2 can be used. Example 1 uses a single-ended m easurement for the CS512 probe; exampl e 2 uses a differential measurement. The exam ple measurem ent instructions that follow do not store data to final st ...

  • Campbell Manufacturing CS512 - page 10

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 6 8. Calibration The multiplier is used to calibrate the CS512 probe. To calculate the m ultiplier: 1) Program the datalogger using a multiplier of one. 2) Place the OxyGuard probe in the air, shad ed from the sun. Wait for readings to stabilize. This m ay take 15 m inutes or m ore. ...

  • Campbell Manufacturing CS512 - page 11

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 7 9. Maintenance The CS512 probe needs little maintenance. Regular cleaning of the m embrane is all that is required. The membrane is ve ry durable and can be cleaned with a cloth or soft paper. Do not scratch it cl ean with your fingernail. 10. Agitator Control In low flow conditio ...

  • Campbell Manufacturing CS512 - page 12

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 8 EXAMPLE 8. Sample Program using P86 and P22 Instructions 45: Do (P86) 1: 41 Set Port 1 Hi gh 46: Excitation with Delay (P22 ) 1: 1 Ex Channel 2: 20 Delay W/Ex (uni ts = 0.01 sec) 3: 0 Delay After Ex (uni ts = 0.01 sec) 4: 0 mV Excita tion 47: Do (P86) 1: 51 Set Port 1 Low 48: End ...

  • Campbell Manufacturing CS512 - page 13

    A-1 Appendix A. Dissolved Oxygen in Fresh Water Table ...

  • Campbell Manufacturing CS512 - page 14

    Appendix A. Dissolved Oxygen in Fre sh Water Table A-2 ...

  • Campbell Manufacturing CS512 - page 15

    This is a bl ank page . ...

  • Campbell Manufacturing CS512 - page 16

    Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 Nort h Logan, Utah 84 321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Afri ca Pty. Lt d. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Aust ralia Pty. Ltd. (CSA) PO Box 444 Thu ...

Produzent Campbell Manufacturing Kategorie Oxygen Equipment

Dokumente, die wir vom Produzenten des Geräts Campbell Manufacturing CS512 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Campbell Manufacturing
- Bedienungsanleitungen CS512
- Produktkarten Campbell Manufacturing
- Informationsbroschüren
- oder Energieetiketten Campbell Manufacturing CS512
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Campbell Manufacturing CS512.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Campbell Manufacturing CS512, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Campbell Manufacturing CS512. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Campbell Manufacturing CS512 ansehen.

Die komplette Bedienungsanleitung des Geräts Campbell Manufacturing CS512, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Campbell Manufacturing CS512 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Campbell Manufacturing CS512 verständlich ist.

Eine gänzliche Bedienungsanleitung von Campbell Manufacturing sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Campbell Manufacturing CS512 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Campbell Manufacturing CS512 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Campbell Manufacturing CS512, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Campbell Manufacturing CS512 - die uns die ersten Schritte während der Nutzung von Campbell Manufacturing CS512 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Campbell Manufacturing CS512 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Campbell Manufacturing CS512 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Campbell Manufacturing CS512?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Campbell Manufacturing CS512 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Campbell Manufacturing CS512 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)