Manual Campbell Manufacturing CS512

16 pages 1.71 mb
Download

Go to site of 16

Summary
  • Campbell Manufacturing CS512 - page 1

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06 Copyright © 2001-2006 Campbell Scientific, Inc. ...

  • Campbell Manufacturing CS512 - page 2

    Warranty and Assistance The CS512 OXYGUARD TYPE III DISSOLVED OXYGEN PROBE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materi als and workmanship under norm al use and service for t welve (12) months from date of shipm ent unless specified otherwi se. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC. 's obligation ...

  • Campbell Manufacturing CS512 - page 3

    i CS512 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. General Information ..................................................... 1 2. Specifications .............................................................. 2 3. Optio ...

  • Campbell Manufacturing CS512 - page 4

    CS512 Table of Contents ii Examples 1. Sample Program using P1 .......................................................................... 5 2. Sample Program using P2 .......................................................................... 5 3. Sample Program using VoltSE .................................................................. 5 4. Sam ...

  • Campbell Manufacturing CS512 - page 5

    1 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe An accurate and reliable sensor is a critical element in any measurement system. The Oxyguard Stationary Probe meets these criteria for the measurement of dissolved oxygen. 1. General Information The Oxyguard Stationary Pro be is a galvanic prob e which produces a millivolt signal ...

  • Campbell Manufacturing CS512 - page 6

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 2 2. Specifications Principle of Measurem ent: Membrane covered galvanic oxygen probe Output Signal: 2.5 to 5 mV per m g 1 -1 Repeatability: Better than ± 0.2 mg/l calibration temperature equals measuring te mperature ± 5 ° C Output Impedance: ∼ 1 kohm Response Time: After equi ...

  • Campbell Manufacturing CS512 - page 7

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 3 3. Optional Probe Accessories PT4-L — Agitator for stagnant condi tions 18026 — DO electrolyte, 1 liter 18027 — Membrane kit , 10 mem branes 4. Optional Agitator The PT4 Agitator is a reli able and robust agitat or for use in conjunction with probes subjected to bio-fouling ...

  • Campbell Manufacturing CS512 - page 8

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 4 FIGURE 4-2. CS512 with PT4 Agitator Optional Repeat Cycle Timer for Agitators : Reciprocating act ion may be controlled by the opti onal solid state Repeat Cycle Tim er. It sends 12 VDC pulses to the agitator coil. The ON-time is 0.25 sec. The OFF-time is adjustab le from 3 to 12 ...

  • Campbell Manufacturing CS512 - page 9

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 5 7. Programming In the CR510, CR10X, and CR 23X datalogger, Instruction P1 or P2 can be used. Example 1 uses a single-ended m easurement for the CS512 probe; exampl e 2 uses a differential measurement. The exam ple measurem ent instructions that follow do not store data to final st ...

  • Campbell Manufacturing CS512 - page 10

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 6 8. Calibration The multiplier is used to calibrate the CS512 probe. To calculate the m ultiplier: 1) Program the datalogger using a multiplier of one. 2) Place the OxyGuard probe in the air, shad ed from the sun. Wait for readings to stabilize. This m ay take 15 m inutes or m ore. ...

  • Campbell Manufacturing CS512 - page 11

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 7 9. Maintenance The CS512 probe needs little maintenance. Regular cleaning of the m embrane is all that is required. The membrane is ve ry durable and can be cleaned with a cloth or soft paper. Do not scratch it cl ean with your fingernail. 10. Agitator Control In low flow conditio ...

  • Campbell Manufacturing CS512 - page 12

    Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 8 EXAMPLE 8. Sample Program using P86 and P22 Instructions 45: Do (P86) 1: 41 Set Port 1 Hi gh 46: Excitation with Delay (P22 ) 1: 1 Ex Channel 2: 20 Delay W/Ex (uni ts = 0.01 sec) 3: 0 Delay After Ex (uni ts = 0.01 sec) 4: 0 mV Excita tion 47: Do (P86) 1: 51 Set Port 1 Low 48: End ...

  • Campbell Manufacturing CS512 - page 13

    A-1 Appendix A. Dissolved Oxygen in Fresh Water Table ...

  • Campbell Manufacturing CS512 - page 14

    Appendix A. Dissolved Oxygen in Fre sh Water Table A-2 ...

  • Campbell Manufacturing CS512 - page 15

    This is a bl ank page . ...

  • Campbell Manufacturing CS512 - page 16

    Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 Nort h Logan, Utah 84 321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Afri ca Pty. Lt d. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Aust ralia Pty. Ltd. (CSA) PO Box 444 Thu ...

Manufacturer Campbell Manufacturing Category Oxygen Equipment

Documents that we receive from a manufacturer of a Campbell Manufacturing CS512 can be divided into several groups. They are, among others:
- Campbell Manufacturing technical drawings
- CS512 manuals
- Campbell Manufacturing product data sheets
- information booklets
- or energy labels Campbell Manufacturing CS512
All of them are important, but the most important information from the point of view of use of the device are in the user manual Campbell Manufacturing CS512.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Campbell Manufacturing CS512, service manual, brief instructions and user manuals Campbell Manufacturing CS512. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Campbell Manufacturing CS512.

A complete manual for the device Campbell Manufacturing CS512, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Campbell Manufacturing CS512 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Campbell Manufacturing CS512.

A complete Campbell Manufacturing manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Campbell Manufacturing CS512 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Campbell Manufacturing CS512, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Campbell Manufacturing CS512, that we can find in the current document
3. Tips how to use the basic functions of the device Campbell Manufacturing CS512 - which should help us in our first steps of using Campbell Manufacturing CS512
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Campbell Manufacturing CS512
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Campbell Manufacturing CS512 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Campbell Manufacturing CS512?

Use the form below

If you did not solve your problem by using a manual Campbell Manufacturing CS512, ask a question using the form below. If a user had a similar problem with Campbell Manufacturing CS512 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)