    TECHNICAL GUIDE AFFINITY SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R-410A MODELS: CZB018 THRU 060 (1.5 THRU 5 NOMINAL TONS ) Due to continuous pr od uct improvement, sp eci fications are subject to change without n otice. Visit us on the web at www .yor k.com Additional rating informa tion can be foun d at www .ari.or g/aridirector y LISTED ISO 90 ...

  • York CZB018 THRU 060 - page 2

    246723-YTG-J-1006 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. PHYSICAL AND ELECTRICAL DA T A MODEL CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Unit Supply V oltage 208-230V , 1 φ, 60Hz Normal V oltage Range 1 187 to ...

  • York CZB018 THRU 060 - page 3

    246723-YTG-J-1006 Unitary Products Group 3 Additional R-410A Charge / TXV Size f or V arious Matche d Sy stems Out door Unit CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Unit Orifice (s) 1 TVM901 1 TVM903 1 T VM903 1 TVM903 1 TVM904 1T V M 4 C 1 1 T VM905 1 TVM905 Factory R-410A Charge, lbs- oz 5-13 6-4 7-4 6-4 8-13 8-12 ...

  • York CZB018 THRU 060 - page 4

    246723-YTG-J-1006 4 Unitary Products Group PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrig erant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing. 2. V erify the TXV and additional char ge required for specific evaporator coil in th e system using the above table. 3. Additional ...

  • York CZB018 THRU 060 - page 5

    246723-YTG-J-1006 Unitary Products Group 5 COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL ELECTRIC HEA T KW 2 W RA TED CFM NET MBH SEER EER TOT AL SENS. 1 PH 13 SEER AC WITH MA CZB0181 1 MA08B 2,5,8,10 17 FC/MC18B 600 18.0 12.1 13.00 1 1.00 MA08B 2,5,8,10 17 FC/MC24B 600 18.0 12.1 13.00 1 1.00 MA08B 2,5 ...

  • York CZB018 THRU 060 - page 6

    246723-YTG-J-1006 6 Unitary Products Group 1 PH 13 SEER AC WITH AHP/ SHP / F*FP CZB0181 1 AHP18 2,5,8 17 – 600 18.0 12.1 13.00 1 1.00 AHP24 2,5,8,10 17 – 600 18.0 12.3 13.00 1 1.00 F*FP024 5,8,1 0 17 – 600 18.0 12.1 13.00 1 1.00 CZB0241 1 AHP24 2,5,8,10 17 – 800 23.0 16.9 13.00 1 1.00 F*FP030 5,8,10,15 17 – 800 23.0 16.7 13.00 1 1.00 CZB0 ...

  • York CZB018 THRU 060 - page 7

    246723-YTG-J-1006 Unitary Products Group 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER 1,2 EER TOT AL SENS. CZB0181 1 450 750 14,17 FC/MC/PC/UC18 600 18.0 12.1 13.00 1 1.00 14,17 FC/MC/PC/UC24 600 18.0 12.1 13.00 1 1.00 14,17 FC/MC/ ...

  • York CZB018 THRU 060 - page 8

    246723-YTG-J-1006 8 Unitary Products Group COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER EER T OTAL SENS. 1 PH 13 SEER AC WITH V ARIABLE SPEED FURNACES 2 CZB0181 1 PV8*A12 FC/MC/PC24A 14 600 18.0 12.2 14.00 1 1.50 PV9*A12 FC/MC/PC24A 14 600 18.0 12.2 14.0 ...

  • York CZB018 THRU 060 - page 9

    246723-YTG-J-1006 Unitary Products Group 9 CZB0421 1 PV8*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*D20 FC/MC/PC48D 24 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 HC60 21 1400 40.5 29.8 1 ...

  • York CZB018 THRU 060 - page 10

    246723-YTG-J-1006 10 Unitary Products Group ACCESSORIES* Hard St art Kit (024-31994-000, 024-319 95-000) - Provides increased starting torque for areas w ith low voltage. TXV Kits - 1 TV09 series thermal exp ans ion valves precisely meter refrigerant for optimum performance Low Ambient Pressure Switch Kit (2LA 06700424) - Allows use of air conditio ...

  • York CZB018 THRU 060 - page 11

    246723-YTG-J-1006 Unitary Products Group 11 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 12

    246723-YTG-J-1006 12 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 13

    246723-YTG-J-1006 Unitary Products Group 13 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 14

    246723-YTG-J-1006 14 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 15

    246723-YTG-J-1006 Unitary Products Group 15 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 16

    246723-YTG-J-1006 16 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 17

    246723-YTG-J-1006 Unitary Products Group 17 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 18

    246723-YTG-J-1006 18 Unitary Products Group NOTES ...

  • York CZB018 THRU 060 - page 19

    246723-YTG-J-1006 Unitary Products Group 19 NOTES ...

  • York CZB018 THRU 060 - page 20

    Subject to change without notice. Printe d in U.S.A. 246723-YTG-J-1006 Copyright © by York International/JCI 2006. All righ ts reserved. Supersedes: 246723-YTG-H-0906 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 NOTES ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York CZB018 THRU 060 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen CZB018 THRU 060
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York CZB018 THRU 060
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York CZB018 THRU 060.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York CZB018 THRU 060, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York CZB018 THRU 060. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York CZB018 THRU 060 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York CZB018 THRU 060, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York CZB018 THRU 060 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York CZB018 THRU 060 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York CZB018 THRU 060 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York CZB018 THRU 060 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York CZB018 THRU 060, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York CZB018 THRU 060 - die uns die ersten Schritte während der Nutzung von York CZB018 THRU 060 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York CZB018 THRU 060 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York CZB018 THRU 060 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York CZB018 THRU 060?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York CZB018 THRU 060 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York CZB018 THRU 060 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)