    TECHNICAL GUIDE AFFINITY SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R-410A MODELS: CZB018 THRU 060 (1.5 THRU 5 NOMINAL TONS ) Due to continuous pr od uct improvement, sp eci fications are subject to change without n otice. Visit us on the web at www .yor k.com Additional rating informa tion can be foun d at www .ari.or g/aridirector y LISTED ISO 90 ...

  • York CZB018 THRU 060 - page 2

    246723-YTG-J-1006 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. PHYSICAL AND ELECTRICAL DA T A MODEL CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Unit Supply V oltage 208-230V , 1 φ, 60Hz Normal V oltage Range 1 187 to ...

  • York CZB018 THRU 060 - page 3

    246723-YTG-J-1006 Unitary Products Group 3 Additional R-410A Charge / TXV Size f or V arious Matche d Sy stems Out door Unit CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Unit Orifice (s) 1 TVM901 1 TVM903 1 T VM903 1 TVM903 1 TVM904 1T V M 4 C 1 1 T VM905 1 TVM905 Factory R-410A Charge, lbs- oz 5-13 6-4 7-4 6-4 8-13 8-12 ...

  • York CZB018 THRU 060 - page 4

    246723-YTG-J-1006 4 Unitary Products Group PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrig erant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing. 2. V erify the TXV and additional char ge required for specific evaporator coil in th e system using the above table. 3. Additional ...

  • York CZB018 THRU 060 - page 5

    246723-YTG-J-1006 Unitary Products Group 5 COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL ELECTRIC HEA T KW 2 W RA TED CFM NET MBH SEER EER TOT AL SENS. 1 PH 13 SEER AC WITH MA CZB0181 1 MA08B 2,5,8,10 17 FC/MC18B 600 18.0 12.1 13.00 1 1.00 MA08B 2,5,8,10 17 FC/MC24B 600 18.0 12.1 13.00 1 1.00 MA08B 2,5 ...

  • York CZB018 THRU 060 - page 6

    246723-YTG-J-1006 6 Unitary Products Group 1 PH 13 SEER AC WITH AHP/ SHP / F*FP CZB0181 1 AHP18 2,5,8 17 – 600 18.0 12.1 13.00 1 1.00 AHP24 2,5,8,10 17 – 600 18.0 12.3 13.00 1 1.00 F*FP024 5,8,1 0 17 – 600 18.0 12.1 13.00 1 1.00 CZB0241 1 AHP24 2,5,8,10 17 – 800 23.0 16.9 13.00 1 1.00 F*FP030 5,8,10,15 17 – 800 23.0 16.7 13.00 1 1.00 CZB0 ...

  • York CZB018 THRU 060 - page 7

    246723-YTG-J-1006 Unitary Products Group 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER 1,2 EER TOT AL SENS. CZB0181 1 450 750 14,17 FC/MC/PC/UC18 600 18.0 12.1 13.00 1 1.00 14,17 FC/MC/PC/UC24 600 18.0 12.1 13.00 1 1.00 14,17 FC/MC/ ...

  • York CZB018 THRU 060 - page 8

    246723-YTG-J-1006 8 Unitary Products Group COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER EER T OTAL SENS. 1 PH 13 SEER AC WITH V ARIABLE SPEED FURNACES 2 CZB0181 1 PV8*A12 FC/MC/PC24A 14 600 18.0 12.2 14.00 1 1.50 PV9*A12 FC/MC/PC24A 14 600 18.0 12.2 14.0 ...

  • York CZB018 THRU 060 - page 9

    246723-YTG-J-1006 Unitary Products Group 9 CZB0421 1 PV8*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*D20 FC/MC/PC48D 24 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 HC60 21 1400 40.5 29.8 1 ...

  • York CZB018 THRU 060 - page 10

    246723-YTG-J-1006 10 Unitary Products Group ACCESSORIES* Hard St art Kit (024-31994-000, 024-319 95-000) - Provides increased starting torque for areas w ith low voltage. TXV Kits - 1 TV09 series thermal exp ans ion valves precisely meter refrigerant for optimum performance Low Ambient Pressure Switch Kit (2LA 06700424) - Allows use of air conditio ...

  • York CZB018 THRU 060 - page 11

    246723-YTG-J-1006 Unitary Products Group 11 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 12

    246723-YTG-J-1006 12 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 13

    246723-YTG-J-1006 Unitary Products Group 13 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 14

    246723-YTG-J-1006 14 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 15

    246723-YTG-J-1006 Unitary Products Group 15 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 16

    246723-YTG-J-1006 16 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York CZB018 THRU 060 - page 17

    246723-YTG-J-1006 Unitary Products Group 17 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York CZB018 THRU 060 - page 18

    246723-YTG-J-1006 18 Unitary Products Group NOTES ...

  • York CZB018 THRU 060 - page 19

    246723-YTG-J-1006 Unitary Products Group 19 NOTES ...

  • York CZB018 THRU 060 - page 20

    Subject to change without notice. Printe d in U.S.A. 246723-YTG-J-1006 Copyright © by York International/JCI 2006. All righ ts reserved. Supersedes: 246723-YTG-H-0906 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 NOTES ...

Manufacturer York Category Air Conditioner

Documents that we receive from a manufacturer of a York CZB018 THRU 060 can be divided into several groups. They are, among others:
- York technical drawings
- CZB018 THRU 060 manuals
- York product data sheets
- information booklets
- or energy labels York CZB018 THRU 060
All of them are important, but the most important information from the point of view of use of the device are in the user manual York CZB018 THRU 060.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York CZB018 THRU 060, service manual, brief instructions and user manuals York CZB018 THRU 060. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York CZB018 THRU 060.

Similar manuals

A complete manual for the device York CZB018 THRU 060, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York CZB018 THRU 060 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York CZB018 THRU 060.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York CZB018 THRU 060 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York CZB018 THRU 060, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York CZB018 THRU 060, that we can find in the current document
3. Tips how to use the basic functions of the device York CZB018 THRU 060 - which should help us in our first steps of using York CZB018 THRU 060
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York CZB018 THRU 060
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York CZB018 THRU 060 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York CZB018 THRU 060?

Use the form below

If you did not solve your problem by using a manual York CZB018 THRU 060, ask a question using the form below. If a user had a similar problem with York CZB018 THRU 060 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)