  • Emerson 1F97-1277 - page 1

    Big Blue T ouchscreen T her mostat with Automa tic Heat/Cool Changeo ver Option Installation and Operating Instructions for Model: APPLICA TIONS 1F97-1277 T ouchscreen Thermostat SPECIFICA TIONS Electrical Rating: Battery Power .......................... mV to 30 V AC, NEC Class II, 50/60 Hz or DC Input-Hardwire ......................... 20 to 30 V ...

  • Emerson 1F97-1277 - page 2

    2 2 "AA" Batteries WIRING CONNECTIONS Refer to equipment manufacturers' instructions for specic system wiring information. After wiring, see CONFIGURA- TION section for proper thermostat conguration. For wiring diagrams, see next page. Wiring diagrams shown are for typical systems and describe the thermostat terminal functions. ...

  • Emerson 1F97-1277 - page 3

    3 Single Stage Connections Refer to equipment manufacturers' instructions for specic system wiring information. This thermostat is designed to operate a single-transformer or two- transformer system. Y ou can congure the thermostat for use with the following systems: SINGLE ST AGE gas, oil or electric. HEA T PUMP TYPE 1 (HP 1). Single st ...

  • Emerson 1F97-1277 - page 4

    4 1 Displays and "Keypad Lockout" when in keypad lockout mode. Displays and "T emperature Limit" and "Keypad Lockout" when limited range is activated and locked. Displays only "T emperature Limit" when limited range is activated. 2 Indicates period of day being programmed. 3 RUN SCHEDULE (run program) button. ...

  • Emerson 1F97-1277 - page 5

    5 T o enter the menu: Press the Menu touch key . Press and hold for 5 seconds the Installer Cong touch key . This displays menu item #1 in the table below . Press to advance to the next menu item or to return to a previous menu item. Press or to change a menu item. Installer Note: T o default the programming, clock and Conguration Menu to the ...

  • Emerson 1F97-1277 - page 6

    6 the backlight on continuously . Selecting dL Of f will turn the backlight on momentarily after any key is pressed. When C terminal is not powered (battery only), dL On enables the momentary backlight whenever a key is pressed. 12) Select Backlight Intensity – This thermostat has the ability to provide two selectable intensities of the back- lig ...

  • Emerson 1F97-1277 - page 7

    7 INST ALLER/CONFIGURA TION MENU 20) Heat T emperature Limit Range – This feature adjusts the highest setpoint temperature for heat. The default setting is 99°F . It can be changed between 62°F and 98°F by pressing the or key . The "temperature limit" icon will be displayed to the left of your setpoint temperature when using this fea ...

  • Emerson 1F97-1277 - page 8

    8 OPERA TING YOUR THERMOST A T Choose the Fan Setting (Auto or On) Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on. Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning. Choose the System Setting (Cool, Off, Heat, Emer , Auto) Press ...

  • Emerson 1F97-1277 - page 9

    9 PROGRAMMING Fill in the blank schedule on the next page then: Enter the Heating Program 1) Press the Menu button and then press Set Schedule. Press SYSTEM button to select either "Heat" or "Cool" in the system switch area indicating the active mode being programmed. Y ou can switch to the other mode by press- ing the system sw ...

  • Emerson 1F97-1277 - page 10

    10 PROGRAMMING Energy Saving Factory Pre-Program The 1F97-1277 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RUN button. The table below shows the factory set heating and cooling schedule for all days of th ...

  • Emerson 1F97-1277 - page 11

    11 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 ft). Three terminals, +, S & - are provided on the terminal block to connect to the White- Rodgers standard wired remote sensor . This sensor will be read by the therm ...

  • Emerson 1F97-1277 - page 12

    www .white-rodger s.com www .emersonc limate.com TROUBLESHOOTING Reset Operation Note: When thermostat is reset, installer conguration menu settings and programming will reset to factory settings. If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wir ...

Fabricante Emerson Categoría Thermostat

Los documentos del dispositivo Emerson 1F97-1277 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Emerson
- manuales de instrucciones 1F97-1277
- hojas de producto Emerson
- folletos informativos
- o etiquetas energéticas Emerson 1F97-1277
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Emerson 1F97-1277.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Emerson 1F97-1277, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Emerson 1F97-1277. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Emerson 1F97-1277.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Emerson 1F97-1277, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Emerson 1F97-1277. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Emerson 1F97-1277.

El manual de instrucciones completo de Emerson debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Emerson 1F97-1277 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Emerson 1F97-1277, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Emerson 1F97-1277 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Emerson 1F97-1277 - que deben facilitarnos los primeros pasos durante el uso de Emerson 1F97-1277
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Emerson 1F97-1277
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Emerson 1F97-1277 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Emerson 1F97-1277?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Emerson 1F97-1277, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Emerson 1F97-1277 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)