    Big Blue T ouchscreen T her mostat with Automa tic Heat/Cool Changeo ver Option Installation and Operating Instructions for Model: APPLICA TIONS 1F97-1277 T ouchscreen Thermostat SPECIFICA TIONS Electrical Rating: Battery Power .......................... mV to 30 V AC, NEC Class II, 50/60 Hz or DC Input-Hardwire ......................... 20 to 30 V ...

  • Emerson 1F97-1277 - page 2

    2 2 "AA" Batteries WIRING CONNECTIONS Refer to equipment manufacturers' instructions for specic system wiring information. After wiring, see CONFIGURA- TION section for proper thermostat conguration. For wiring diagrams, see next page. Wiring diagrams shown are for typical systems and describe the thermostat terminal functions. ...

  • Emerson 1F97-1277 - page 3

    3 Single Stage Connections Refer to equipment manufacturers' instructions for specic system wiring information. This thermostat is designed to operate a single-transformer or two- transformer system. Y ou can congure the thermostat for use with the following systems: SINGLE ST AGE gas, oil or electric. HEA T PUMP TYPE 1 (HP 1). Single st ...

  • Emerson 1F97-1277 - page 4

    4 1 Displays and "Keypad Lockout" when in keypad lockout mode. Displays and "T emperature Limit" and "Keypad Lockout" when limited range is activated and locked. Displays only "T emperature Limit" when limited range is activated. 2 Indicates period of day being programmed. 3 RUN SCHEDULE (run program) button. ...

  • Emerson 1F97-1277 - page 5

    5 T o enter the menu: Press the Menu touch key . Press and hold for 5 seconds the Installer Cong touch key . This displays menu item #1 in the table below . Press to advance to the next menu item or to return to a previous menu item. Press or to change a menu item. Installer Note: T o default the programming, clock and Conguration Menu to the ...

  • Emerson 1F97-1277 - page 6

    6 the backlight on continuously . Selecting dL Of f will turn the backlight on momentarily after any key is pressed. When C terminal is not powered (battery only), dL On enables the momentary backlight whenever a key is pressed. 12) Select Backlight Intensity – This thermostat has the ability to provide two selectable intensities of the back- lig ...

  • Emerson 1F97-1277 - page 7

    7 INST ALLER/CONFIGURA TION MENU 20) Heat T emperature Limit Range – This feature adjusts the highest setpoint temperature for heat. The default setting is 99°F . It can be changed between 62°F and 98°F by pressing the or key . The "temperature limit" icon will be displayed to the left of your setpoint temperature when using this fea ...

  • Emerson 1F97-1277 - page 8

    8 OPERA TING YOUR THERMOST A T Choose the Fan Setting (Auto or On) Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on. Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning. Choose the System Setting (Cool, Off, Heat, Emer , Auto) Press ...

  • Emerson 1F97-1277 - page 9

    9 PROGRAMMING Fill in the blank schedule on the next page then: Enter the Heating Program 1) Press the Menu button and then press Set Schedule. Press SYSTEM button to select either "Heat" or "Cool" in the system switch area indicating the active mode being programmed. Y ou can switch to the other mode by press- ing the system sw ...

  • Emerson 1F97-1277 - page 10

    10 PROGRAMMING Energy Saving Factory Pre-Program The 1F97-1277 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RUN button. The table below shows the factory set heating and cooling schedule for all days of th ...

  • Emerson 1F97-1277 - page 11

    11 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 ft). Three terminals, +, S & - are provided on the terminal block to connect to the White- Rodgers standard wired remote sensor . This sensor will be read by the therm ...

  • Emerson 1F97-1277 - page 12

    www .white-rodger s.com www .emersonc limate.com TROUBLESHOOTING Reset Operation Note: When thermostat is reset, installer conguration menu settings and programming will reset to factory settings. If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wir ...

Manufacturer Emerson Category Thermostat

Documents that we receive from a manufacturer of a Emerson 1F97-1277 can be divided into several groups. They are, among others:
- Emerson technical drawings
- 1F97-1277 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 1F97-1277
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 1F97-1277.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 1F97-1277, service manual, brief instructions and user manuals Emerson 1F97-1277. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 1F97-1277.

Similar manuals

A complete manual for the device Emerson 1F97-1277, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 1F97-1277 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 1F97-1277.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 1F97-1277 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 1F97-1277, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 1F97-1277, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 1F97-1277 - which should help us in our first steps of using Emerson 1F97-1277
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 1F97-1277
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson 1F97-1277 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson 1F97-1277?

Use the form below

If you did not solve your problem by using a manual Emerson 1F97-1277, ask a question using the form below. If a user had a similar problem with Emerson 1F97-1277 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)