    Big Blue T ouchscreen T her mostat with Automa tic Heat/Cool Changeo ver Option Installation and Operating Instructions for Model: APPLICA TIONS 1F97-1277 T ouchscreen Thermostat SPECIFICA TIONS Electrical Rating: Battery Power .......................... mV to 30 V AC, NEC Class II, 50/60 Hz or DC Input-Hardwire ......................... 20 to 30 V ...

  • Emerson 1F97-1277 - page 2

    2 2 "AA" Batteries WIRING CONNECTIONS Refer to equipment manufacturers' instructions for specic system wiring information. After wiring, see CONFIGURA- TION section for proper thermostat conguration. For wiring diagrams, see next page. Wiring diagrams shown are for typical systems and describe the thermostat terminal functions. ...

  • Emerson 1F97-1277 - page 3

    3 Single Stage Connections Refer to equipment manufacturers' instructions for specic system wiring information. This thermostat is designed to operate a single-transformer or two- transformer system. Y ou can congure the thermostat for use with the following systems: SINGLE ST AGE gas, oil or electric. HEA T PUMP TYPE 1 (HP 1). Single st ...

  • Emerson 1F97-1277 - page 4

    4 1 Displays and "Keypad Lockout" when in keypad lockout mode. Displays and "T emperature Limit" and "Keypad Lockout" when limited range is activated and locked. Displays only "T emperature Limit" when limited range is activated. 2 Indicates period of day being programmed. 3 RUN SCHEDULE (run program) button. ...

  • Emerson 1F97-1277 - page 5

    5 T o enter the menu: Press the Menu touch key . Press and hold for 5 seconds the Installer Cong touch key . This displays menu item #1 in the table below . Press to advance to the next menu item or to return to a previous menu item. Press or to change a menu item. Installer Note: T o default the programming, clock and Conguration Menu to the ...

  • Emerson 1F97-1277 - page 6

    6 the backlight on continuously . Selecting dL Of f will turn the backlight on momentarily after any key is pressed. When C terminal is not powered (battery only), dL On enables the momentary backlight whenever a key is pressed. 12) Select Backlight Intensity – This thermostat has the ability to provide two selectable intensities of the back- lig ...

  • Emerson 1F97-1277 - page 7

    7 INST ALLER/CONFIGURA TION MENU 20) Heat T emperature Limit Range – This feature adjusts the highest setpoint temperature for heat. The default setting is 99°F . It can be changed between 62°F and 98°F by pressing the or key . The "temperature limit" icon will be displayed to the left of your setpoint temperature when using this fea ...

  • Emerson 1F97-1277 - page 8

    8 OPERA TING YOUR THERMOST A T Choose the Fan Setting (Auto or On) Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on. Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning. Choose the System Setting (Cool, Off, Heat, Emer , Auto) Press ...

  • Emerson 1F97-1277 - page 9

    9 PROGRAMMING Fill in the blank schedule on the next page then: Enter the Heating Program 1) Press the Menu button and then press Set Schedule. Press SYSTEM button to select either "Heat" or "Cool" in the system switch area indicating the active mode being programmed. Y ou can switch to the other mode by press- ing the system sw ...

  • Emerson 1F97-1277 - page 10

    10 PROGRAMMING Energy Saving Factory Pre-Program The 1F97-1277 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RUN button. The table below shows the factory set heating and cooling schedule for all days of th ...

  • Emerson 1F97-1277 - page 11

    11 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 ft). Three terminals, +, S & - are provided on the terminal block to connect to the White- Rodgers standard wired remote sensor . This sensor will be read by the therm ...

  • Emerson 1F97-1277 - page 12

    www .white-rodger s.com www .emersonc limate.com TROUBLESHOOTING Reset Operation Note: When thermostat is reset, installer conguration menu settings and programming will reset to factory settings. If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the wir ...

メーカー Emerson カテゴリー Thermostat

Emerson 1F97-1277のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1F97-1277の取扱説明書
- Emersonの製品カード
- パンフレット
- またはEmerson 1F97-1277の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson 1F97-1277の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson 1F97-1277の取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson 1F97-1277のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson 1F97-1277の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Emerson 1F97-1277デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson 1F97-1277を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson 1F97-1277ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emersonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson 1F97-1277の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson 1F97-1277の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson 1F97-1277に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson 1F97-1277デバイスの基本機能を使うにあたってのヒント。 Emerson 1F97-1277のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson 1F97-1277に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson 1F97-1277のメーカー/サービスへの連絡先に関する情報。

Emerson 1F97-1277についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson 1F97-1277の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson 1F97-1277で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)