Manual de instrucciones Mitsubishi Electronics PUHZ-RP250YHM-A

16 de páginas 1.02 mb
Descargar

Pasar a la página of 16

Summary
  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 1

    OUTDOOR UNIT PUHZ-RP250YHM-A For use with R410A INST ALLA TION MANU AL F or saf e and correct use, please read this installation manual thoroughly bef ore installing the air-conditioner unit. GB ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 2

    2 5 [Fig. 5.0.1] [Fig. 6.0.1] 6 (2) (1) (3) (4) [Fig. 5.0.2] <A> : T op view <B> : Side view <C> : When there is little space up to an obstruction A :F ront B : Unit height C :B a c k D : Air outlet guide (Procured at the site) A :F ront B : Must be open C :W all height (H) 15 * 15 * 450 * 300 * <A> A 100 * 450 * 50 * 50 * & ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 3

    3 7 [Fig. 7.1.1] 30mm A B C 8 8.2 [Fig. 8.2.1] A : Outdoor unit B : Indoor unit A B A 7.1 Å Outdoor model RP250 ı Liquid pipe ø9.52 Ç Gas pipe ø22.2 A 9.2 9 [Fig. 9.2.1] [Fig. 9.2.2] <A> Valve liquid side/ flared type A B C H I G F E D () <B> Valve gas side/ flanged type () [Fig. 9.2.3] A B [Fig. 9.2.4] A E D C B A : Close-packed p ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 4

    4 [Fig. 9.3.1] [Fig. 9.3.3] [Fig. 9.3.2] 9.3 A A : Nitrogen gas B :T o indoor unit C : System analyzer D : Low knob E : Hi knob F :V alve G : Liquid pipe H : Gas pipe I : Outdoor unit J : Service port A : System analyzer B : Low knob C : Hi knob D :V alve E : Liquid pipe F : Gas pipe G : Service port H : Three-way joint I :V alve J :V alve K : R410 ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 5

    5 [Fig. 10.4.1] A : Switch (Breakers f or wiring and current leakage) B : Breakers f or current leakage C : Outdoor unit BA C 3N~380–415V L 1 , L 2 , L 3, N PE C L1 L2 L3 N Terminal block for indoor – outdoor transmission line (TB3) Power supply terminal block (TB1) Control box A B [Fig. 10.2.1] 10.3 10.2 [Fig. 10.2.2] A B C [Fig. 10.3.1] 10 A ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 6

    6 D F E I NL P GR RU TR CZ SV SL HG PO GB Contents 1. Safety precautions 1.1. Bef ore installation and electric work s Before installing the unit, make sure y ou read all the “Safety precautions”. s The “Safety precautions” provide very important points re- garding safety . Make sure y ou follo w them. Symbols used in the text W arning: Des ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 7

    7 D F E I NL P GR RU TR CZ SV SL HG PO GB 1.4. Before installation (relocation) - electri- cal work Caution: • Ground the unit. - Do not connect the ground wire to gas or water pipes, lightning rods, or telephone ground lines. Improper grounding may result in electric shock. • Install the power cable so that tension is not applied to the cable. ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 8

    8 D F E I NL P GR RU TR CZ SV SL HG PO GB 7. Installation of unit 7.1. Installation [Fig. 7.1.1] (P .3) A M10 anchor bolt procured at the site. B Cor ner is not seated. C Fixing brack et for the hole-in anchor bolt (3 locations to fix with scre ws). • Fix unit tightly with bolts so that unit will not f all down due to earthquakes or strong winds. ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 9

    9 D F E I NL P GR RU TR CZ SV SL HG PO GB 8. Refrigerant piping installation The pipe is connected via a terminal-branch type connection in which refrigerant piping from the outdoor unit is branched at the terminal and is connected to each of the indoor units. The method of pipe connection is as follows: flare connection for the indoor units, gas p ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 10

    10 D F E I NL P GR RU TR CZ SV SL HG PO GB At the time of shipping, the outdoor unit is charged with refrigerant. This charge does not include the amount needed for e xtended piping and addi- tional charging of each refrigerant line will be required on site. In order that future servicing may be properly provided, alwa ys keep a record of the siz e ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 11

    11 D F E I NL P GR RU TR CZ SV SL HG PO GB Caution: Only use refrigerant R410A. - The use of other refrigerants such as R22 or R407C, which contains chlorine, will deteriorate the refrigerating machine oil or cause the compressor to malfunc- tion. 2 Evacuation Evacuate with the valve of the outdoor unit closed and evacuate both the con- nection pip ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 12

    12 D F E I NL P GR RU TR CZ SV SL HG PO GB 1. Use dedicated power supplies f or the outdoor unit and indoor unit. 2. Bear in mind ambient conditions (ambient temperature,direct sunlight, rain water ,etc.) when proceeding with the wiring and co nnections. 3. The wire size is the minimum v alue for metal conduit wiring. If the v oltage drops, use a w ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 13

    13 D F E I NL P GR RU TR CZ SV SL HG PO GB 11. T est run 11.1. The f ollowing phenomena do not represent faults. Display of remote controller Normal display Defrost display No lighting Heat ready “H0” or “PLEASE W AIT” flashes Normal display Normal display Normal display Cause Ultra-low speed operation is commenced at thermostat OFF . Light ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 14

    GB E F I NL E P GR RU TR ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 15

    GB E F NL E P GR RU TR ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 16

    WT05737X01 Printed in Japan HEAD OFFICE: T OKY O BLDG., 2-7-3, MARUNOUCHI, CHIY OD A-KU , T OKY O 100-8310, JAP AN Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at ...

Fabricante Mitsubishi Electronics Categoría Air Conditioner

Los documentos del dispositivo Mitsubishi Electronics PUHZ-RP250YHM-A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Mitsubishi Electronics
- manuales de instrucciones PUHZ-RP250YHM-A
- hojas de producto Mitsubishi Electronics
- folletos informativos
- o etiquetas energéticas Mitsubishi Electronics PUHZ-RP250YHM-A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Mitsubishi Electronics PUHZ-RP250YHM-A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Mitsubishi Electronics PUHZ-RP250YHM-A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Mitsubishi Electronics PUHZ-RP250YHM-A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Mitsubishi Electronics PUHZ-RP250YHM-A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Mitsubishi Electronics PUHZ-RP250YHM-A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Mitsubishi Electronics PUHZ-RP250YHM-A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Mitsubishi Electronics PUHZ-RP250YHM-A.

El manual de instrucciones completo de Mitsubishi Electronics debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Mitsubishi Electronics PUHZ-RP250YHM-A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Mitsubishi Electronics PUHZ-RP250YHM-A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Mitsubishi Electronics PUHZ-RP250YHM-A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Mitsubishi Electronics PUHZ-RP250YHM-A - que deben facilitarnos los primeros pasos durante el uso de Mitsubishi Electronics PUHZ-RP250YHM-A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Mitsubishi Electronics PUHZ-RP250YHM-A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Mitsubishi Electronics PUHZ-RP250YHM-A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Mitsubishi Electronics PUHZ-RP250YHM-A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Mitsubishi Electronics PUHZ-RP250YHM-A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Mitsubishi Electronics PUHZ-RP250YHM-A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)