Manuel d’utilisation Mitsubishi Electronics PUHZ-RP250YHM-A

16 pages 1.02 mb
Télécharger

Aller à la page of 16

Summary
  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 1

    OUTDOOR UNIT PUHZ-RP250YHM-A For use with R410A INST ALLA TION MANU AL F or saf e and correct use, please read this installation manual thoroughly bef ore installing the air-conditioner unit. GB ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 2

    2 5 [Fig. 5.0.1] [Fig. 6.0.1] 6 (2) (1) (3) (4) [Fig. 5.0.2] <A> : T op view <B> : Side view <C> : When there is little space up to an obstruction A :F ront B : Unit height C :B a c k D : Air outlet guide (Procured at the site) A :F ront B : Must be open C :W all height (H) 15 * 15 * 450 * 300 * <A> A 100 * 450 * 50 * 50 * & ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 3

    3 7 [Fig. 7.1.1] 30mm A B C 8 8.2 [Fig. 8.2.1] A : Outdoor unit B : Indoor unit A B A 7.1 Å Outdoor model RP250 ı Liquid pipe ø9.52 Ç Gas pipe ø22.2 A 9.2 9 [Fig. 9.2.1] [Fig. 9.2.2] <A> Valve liquid side/ flared type A B C H I G F E D () <B> Valve gas side/ flanged type () [Fig. 9.2.3] A B [Fig. 9.2.4] A E D C B A : Close-packed p ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 4

    4 [Fig. 9.3.1] [Fig. 9.3.3] [Fig. 9.3.2] 9.3 A A : Nitrogen gas B :T o indoor unit C : System analyzer D : Low knob E : Hi knob F :V alve G : Liquid pipe H : Gas pipe I : Outdoor unit J : Service port A : System analyzer B : Low knob C : Hi knob D :V alve E : Liquid pipe F : Gas pipe G : Service port H : Three-way joint I :V alve J :V alve K : R410 ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 5

    5 [Fig. 10.4.1] A : Switch (Breakers f or wiring and current leakage) B : Breakers f or current leakage C : Outdoor unit BA C 3N~380–415V L 1 , L 2 , L 3, N PE C L1 L2 L3 N Terminal block for indoor – outdoor transmission line (TB3) Power supply terminal block (TB1) Control box A B [Fig. 10.2.1] 10.3 10.2 [Fig. 10.2.2] A B C [Fig. 10.3.1] 10 A ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 6

    6 D F E I NL P GR RU TR CZ SV SL HG PO GB Contents 1. Safety precautions 1.1. Bef ore installation and electric work s Before installing the unit, make sure y ou read all the “Safety precautions”. s The “Safety precautions” provide very important points re- garding safety . Make sure y ou follo w them. Symbols used in the text W arning: Des ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 7

    7 D F E I NL P GR RU TR CZ SV SL HG PO GB 1.4. Before installation (relocation) - electri- cal work Caution: • Ground the unit. - Do not connect the ground wire to gas or water pipes, lightning rods, or telephone ground lines. Improper grounding may result in electric shock. • Install the power cable so that tension is not applied to the cable. ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 8

    8 D F E I NL P GR RU TR CZ SV SL HG PO GB 7. Installation of unit 7.1. Installation [Fig. 7.1.1] (P .3) A M10 anchor bolt procured at the site. B Cor ner is not seated. C Fixing brack et for the hole-in anchor bolt (3 locations to fix with scre ws). • Fix unit tightly with bolts so that unit will not f all down due to earthquakes or strong winds. ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 9

    9 D F E I NL P GR RU TR CZ SV SL HG PO GB 8. Refrigerant piping installation The pipe is connected via a terminal-branch type connection in which refrigerant piping from the outdoor unit is branched at the terminal and is connected to each of the indoor units. The method of pipe connection is as follows: flare connection for the indoor units, gas p ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 10

    10 D F E I NL P GR RU TR CZ SV SL HG PO GB At the time of shipping, the outdoor unit is charged with refrigerant. This charge does not include the amount needed for e xtended piping and addi- tional charging of each refrigerant line will be required on site. In order that future servicing may be properly provided, alwa ys keep a record of the siz e ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 11

    11 D F E I NL P GR RU TR CZ SV SL HG PO GB Caution: Only use refrigerant R410A. - The use of other refrigerants such as R22 or R407C, which contains chlorine, will deteriorate the refrigerating machine oil or cause the compressor to malfunc- tion. 2 Evacuation Evacuate with the valve of the outdoor unit closed and evacuate both the con- nection pip ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 12

    12 D F E I NL P GR RU TR CZ SV SL HG PO GB 1. Use dedicated power supplies f or the outdoor unit and indoor unit. 2. Bear in mind ambient conditions (ambient temperature,direct sunlight, rain water ,etc.) when proceeding with the wiring and co nnections. 3. The wire size is the minimum v alue for metal conduit wiring. If the v oltage drops, use a w ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 13

    13 D F E I NL P GR RU TR CZ SV SL HG PO GB 11. T est run 11.1. The f ollowing phenomena do not represent faults. Display of remote controller Normal display Defrost display No lighting Heat ready “H0” or “PLEASE W AIT” flashes Normal display Normal display Normal display Cause Ultra-low speed operation is commenced at thermostat OFF . Light ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 14

    GB E F I NL E P GR RU TR ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 15

    GB E F NL E P GR RU TR ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 16

    WT05737X01 Printed in Japan HEAD OFFICE: T OKY O BLDG., 2-7-3, MARUNOUCHI, CHIY OD A-KU , T OKY O 100-8310, JAP AN Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at ...

Fabricant Mitsubishi Electronics Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilMitsubishi Electronics PUHZ-RP250YHM-A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Mitsubishi Electronics
- manuels d’utilisations PUHZ-RP250YHM-A
- fiches produit Mitsubishi Electronics
- dépliants
- ou étiquettes-énergie Mitsubishi Electronics PUHZ-RP250YHM-A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Mitsubishi Electronics PUHZ-RP250YHM-A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Mitsubishi Electronics PUHZ-RP250YHM-A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Mitsubishi Electronics PUHZ-RP250YHM-A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Mitsubishi Electronics PUHZ-RP250YHM-A.

Manuel d’utilisation complet de l’appareil Mitsubishi Electronics PUHZ-RP250YHM-A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Mitsubishi Electronics PUHZ-RP250YHM-A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Mitsubishi Electronics PUHZ-RP250YHM-A.

Le manuel d’utilisation complet Mitsubishi Electronics, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Mitsubishi Electronics PUHZ-RP250YHM-A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Mitsubishi Electronics PUHZ-RP250YHM-A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMitsubishi Electronics PUHZ-RP250YHM-A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Mitsubishi Electronics PUHZ-RP250YHM-A - qui devraient nous aider dans les premières étapes lors de l'utilisation Mitsubishi Electronics PUHZ-RP250YHM-A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Mitsubishi Electronics PUHZ-RP250YHM-A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Mitsubishi Electronics PUHZ-RP250YHM-A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Mitsubishi Electronics PUHZ-RP250YHM-A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Mitsubishi Electronics PUHZ-RP250YHM-A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Mitsubishi Electronics PUHZ-RP250YHM-A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)