Manuale per l’uso Mitsubishi Electronics PUHZ-RP250YHM-A

16 pagine 1.02 mb
Scarica

Vai alla pagina of 16

Summary
  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 1

    OUTDOOR UNIT PUHZ-RP250YHM-A For use with R410A INST ALLA TION MANU AL F or saf e and correct use, please read this installation manual thoroughly bef ore installing the air-conditioner unit. GB ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 2

    2 5 [Fig. 5.0.1] [Fig. 6.0.1] 6 (2) (1) (3) (4) [Fig. 5.0.2] <A> : T op view <B> : Side view <C> : When there is little space up to an obstruction A :F ront B : Unit height C :B a c k D : Air outlet guide (Procured at the site) A :F ront B : Must be open C :W all height (H) 15 * 15 * 450 * 300 * <A> A 100 * 450 * 50 * 50 * & ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 3

    3 7 [Fig. 7.1.1] 30mm A B C 8 8.2 [Fig. 8.2.1] A : Outdoor unit B : Indoor unit A B A 7.1 Å Outdoor model RP250 ı Liquid pipe ø9.52 Ç Gas pipe ø22.2 A 9.2 9 [Fig. 9.2.1] [Fig. 9.2.2] <A> Valve liquid side/ flared type A B C H I G F E D () <B> Valve gas side/ flanged type () [Fig. 9.2.3] A B [Fig. 9.2.4] A E D C B A : Close-packed p ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 4

    4 [Fig. 9.3.1] [Fig. 9.3.3] [Fig. 9.3.2] 9.3 A A : Nitrogen gas B :T o indoor unit C : System analyzer D : Low knob E : Hi knob F :V alve G : Liquid pipe H : Gas pipe I : Outdoor unit J : Service port A : System analyzer B : Low knob C : Hi knob D :V alve E : Liquid pipe F : Gas pipe G : Service port H : Three-way joint I :V alve J :V alve K : R410 ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 5

    5 [Fig. 10.4.1] A : Switch (Breakers f or wiring and current leakage) B : Breakers f or current leakage C : Outdoor unit BA C 3N~380–415V L 1 , L 2 , L 3, N PE C L1 L2 L3 N Terminal block for indoor – outdoor transmission line (TB3) Power supply terminal block (TB1) Control box A B [Fig. 10.2.1] 10.3 10.2 [Fig. 10.2.2] A B C [Fig. 10.3.1] 10 A ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 6

    6 D F E I NL P GR RU TR CZ SV SL HG PO GB Contents 1. Safety precautions 1.1. Bef ore installation and electric work s Before installing the unit, make sure y ou read all the “Safety precautions”. s The “Safety precautions” provide very important points re- garding safety . Make sure y ou follo w them. Symbols used in the text W arning: Des ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 7

    7 D F E I NL P GR RU TR CZ SV SL HG PO GB 1.4. Before installation (relocation) - electri- cal work Caution: • Ground the unit. - Do not connect the ground wire to gas or water pipes, lightning rods, or telephone ground lines. Improper grounding may result in electric shock. • Install the power cable so that tension is not applied to the cable. ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 8

    8 D F E I NL P GR RU TR CZ SV SL HG PO GB 7. Installation of unit 7.1. Installation [Fig. 7.1.1] (P .3) A M10 anchor bolt procured at the site. B Cor ner is not seated. C Fixing brack et for the hole-in anchor bolt (3 locations to fix with scre ws). • Fix unit tightly with bolts so that unit will not f all down due to earthquakes or strong winds. ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 9

    9 D F E I NL P GR RU TR CZ SV SL HG PO GB 8. Refrigerant piping installation The pipe is connected via a terminal-branch type connection in which refrigerant piping from the outdoor unit is branched at the terminal and is connected to each of the indoor units. The method of pipe connection is as follows: flare connection for the indoor units, gas p ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 10

    10 D F E I NL P GR RU TR CZ SV SL HG PO GB At the time of shipping, the outdoor unit is charged with refrigerant. This charge does not include the amount needed for e xtended piping and addi- tional charging of each refrigerant line will be required on site. In order that future servicing may be properly provided, alwa ys keep a record of the siz e ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 11

    11 D F E I NL P GR RU TR CZ SV SL HG PO GB Caution: Only use refrigerant R410A. - The use of other refrigerants such as R22 or R407C, which contains chlorine, will deteriorate the refrigerating machine oil or cause the compressor to malfunc- tion. 2 Evacuation Evacuate with the valve of the outdoor unit closed and evacuate both the con- nection pip ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 12

    12 D F E I NL P GR RU TR CZ SV SL HG PO GB 1. Use dedicated power supplies f or the outdoor unit and indoor unit. 2. Bear in mind ambient conditions (ambient temperature,direct sunlight, rain water ,etc.) when proceeding with the wiring and co nnections. 3. The wire size is the minimum v alue for metal conduit wiring. If the v oltage drops, use a w ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 13

    13 D F E I NL P GR RU TR CZ SV SL HG PO GB 11. T est run 11.1. The f ollowing phenomena do not represent faults. Display of remote controller Normal display Defrost display No lighting Heat ready “H0” or “PLEASE W AIT” flashes Normal display Normal display Normal display Cause Ultra-low speed operation is commenced at thermostat OFF . Light ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 14

    GB E F I NL E P GR RU TR ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 15

    GB E F NL E P GR RU TR ...

  • Mitsubishi Electronics PUHZ-RP250YHM-A - page 16

    WT05737X01 Printed in Japan HEAD OFFICE: T OKY O BLDG., 2-7-3, MARUNOUCHI, CHIY OD A-KU , T OKY O 100-8310, JAP AN Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at ...

Fabbricante Mitsubishi Electronics Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoMitsubishi Electronics PUHZ-RP250YHM-A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Mitsubishi Electronics
- manuali per l’uso PUHZ-RP250YHM-A
- schede prodotto Mitsubishi Electronics
- opuscoli
- o etichette energetiche Mitsubishi Electronics PUHZ-RP250YHM-A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Mitsubishi Electronics PUHZ-RP250YHM-A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Mitsubishi Electronics PUHZ-RP250YHM-A, manuali di manutenzione, brevi manuali o manuali utente Mitsubishi Electronics PUHZ-RP250YHM-A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Mitsubishi Electronics PUHZ-RP250YHM-A.

Manuale completo del dispositivo Mitsubishi Electronics PUHZ-RP250YHM-A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Mitsubishi Electronics PUHZ-RP250YHM-A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Mitsubishi Electronics PUHZ-RP250YHM-A.

Il manuale per l’uso completo Mitsubishi Electronics, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Mitsubishi Electronics PUHZ-RP250YHM-A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Mitsubishi Electronics PUHZ-RP250YHM-A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Mitsubishi Electronics PUHZ-RP250YHM-A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Mitsubishi Electronics PUHZ-RP250YHM-A - che ci dovrebbe aiutare nei primi passi durante l'uso Mitsubishi Electronics PUHZ-RP250YHM-A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Mitsubishi Electronics PUHZ-RP250YHM-A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Mitsubishi Electronics PUHZ-RP250YHM-A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Mitsubishi Electronics PUHZ-RP250YHM-A?

Utilizza il modulo sottostante

Se non hai risolto il problema con Mitsubishi Electronics PUHZ-RP250YHM-A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Mitsubishi Electronics PUHZ-RP250YHM-A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)