Manual de instrucciones Faber Remote Blower

16 de páginas 1.24 mb
Descargar

Pasar a la página of 16

Summary
  • Faber Remote Blower - page 1

    Instruction Manual READ AND SA VE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner . The homeowner must keep these instructions for future reference and for local electrical inspectors’ use. Concept Remote Blower ...

  • Faber Remote Blower - page 2

    2 EN CONTENTS WARNING 3 CHARACTERISTICS 5 INST ALLA TION 8 USE 13 MAINTENANCE 1 4 ...

  • Faber Remote Blower - page 3

    3 EN READ THESE INSTRUCTIONS BEFORE YOU ST ART INST ALLING THIS RANGEHOOD READ AND SA VE THESE INSTRUCTIONS W ARNING: - T O REDUCE THE RISK OF A RANGE T OP GREASE FIRE : Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always turn hood ON ...

  • Faber Remote Blower - page 4

    4 EN This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever necessary . A UL Listed, 1/2" con duit connector must be provided at each end of the power supply cable (a ...

  • Faber Remote Blower - page 5

    5 EN 1 3 4 5 10 11 12 13 G E F D C A 2 CHARACTERISTICS Components Q.ty 1 1 Hood Body , complete with: Blower, Filters, Controls 2 1 Built-in hood body case 3 1 Rear remote motor connection panel 4 1 T op air outlet flange with valve 5 1 T op air outlet plug 10 1 Light 11 4 Support arms 12 2 Bush masking plug 13 2 Arm support bush A 10 Screws 3,5 x ...

  • Faber Remote Blower - page 6

    6 EN Dimensional chart - Hood Distance from the Hob ...

  • Faber Remote Blower - page 7

    7 EN Dimensional chart - LIGHT ...

  • Faber Remote Blower - page 8

    8 EN INST ALLA TION The hood can be installed in the following ways: top air outlet, bottom air outlet, rear air outlet. Once the desired configuration has been chosen (see the diagrams below) it will be necessary to provide an opening in the wall where to house the built-in hood body case. Besides the air ducting pipes, basing on the chosen config ...

  • Faber Remote Blower - page 9

    9 EN LIGHTING UNIT INST ALLA TION SCHEME LIGHTING UNIT LOWER BORDER SHALL BE INST ALLED A T THE MINIMUM DIST ANCE OF 34 9/16 IN. ABOVE THE COOKING SURF ACE. W ith the aid of the drilling template provided mark the necessary holes and drill them. ø15/16 TO P OR BOTTOM AIR OUTLET CONFIGURA TION The hood is manufactured with the air outlet at the top ...

  • Faber Remote Blower - page 10

    10 EN REAR AIR OUTLET CONFIGURA TION • Remove the suction panel by unfastening the 8 screws around the frame. • Remove the metal grease filters. • Remove the metal profile fixed to the flange by unfastening the 5 screws. • Fit the air outlet plug into the top air outlet. • Remove the rear air outlet plug . Built-in hood body case installa ...

  • Faber Remote Blower - page 11

    11 EN Hood body installation • In case of the bottom air outlet configuration the hood body has to be turned 180°. • Remove the top cover of the terminal box by unfastening the two screws fixing it to the hood casing. • W ith the aid of pliers brake through a hole inside the terminal box providing thus for a passage of the electrical connect ...

  • Faber Remote Blower - page 12

    12 EN Lighting unit installation • Provide for passage of the electrical connection wires with the hood body . • Slide the top cover downwards, unfastening the two side screws and taking care not to scratch the tubular support members. • Insert the 4 plugs D into the earlier drilled holes. • Decide the height of the light; loosen the grub s ...

  • Faber Remote Blower - page 13

    13 EN Electrical connection ELECTRICAL SHOCK HAZARD • Disconnect power before making electrical connctions. • Connect ground wire to green ground screw in terminal box. ! W ARNING green ground screw hood wiring purple wiring red wiring hood wiring black wiring white wiring power supply conduit light wiring exterior blower wiring twist-on connec ...

  • Faber Remote Blower - page 14

    14 EN MAINTENANCE Grease filters CLEANING MET AL GREASE FIL TERS • Alarm signal reset • Switch off the lights and extractor motor . • Press button T3 for at least 3 seconds, until the leds start to flash. Cleaning the filters • Open the suction cover using the lever provided. • The filters are washable and must be cleaned when the Led S1 ...

  • Faber Remote Blower - page 15

    15 EN Electric Diagram Lighting LIGHT REPLACEMENT 20 W halogen light. • Extract the lamp from the Support. • Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes. ...

  • Faber Remote Blower - page 16

    436002499_02 - 041 103 ...

Fabricante Faber Categoría Blower

Los documentos del dispositivo Faber Remote Blower que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Faber
- manuales de instrucciones Remote Blower
- hojas de producto Faber
- folletos informativos
- o etiquetas energéticas Faber Remote Blower
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Faber Remote Blower.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Faber Remote Blower, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Faber Remote Blower. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Faber Remote Blower.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Faber Remote Blower, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Faber Remote Blower. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Faber Remote Blower.

El manual de instrucciones completo de Faber debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Faber Remote Blower - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Faber Remote Blower, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Faber Remote Blower que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Faber Remote Blower - que deben facilitarnos los primeros pasos durante el uso de Faber Remote Blower
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Faber Remote Blower
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Faber Remote Blower en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Faber Remote Blower?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Faber Remote Blower, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Faber Remote Blower probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)