Инструкция обслуживания Faber Remote Blower

16 страниц 1.24 mb
Скачать

Перейти на страницу of 16

Summary
  • Faber Remote Blower - page 1

    Instruction Manual READ AND SA VE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner . The homeowner must keep these instructions for future reference and for local electrical inspectors’ use. Concept Remote Blower ...

  • Faber Remote Blower - page 2

    2 EN CONTENTS WARNING 3 CHARACTERISTICS 5 INST ALLA TION 8 USE 13 MAINTENANCE 1 4 ...

  • Faber Remote Blower - page 3

    3 EN READ THESE INSTRUCTIONS BEFORE YOU ST ART INST ALLING THIS RANGEHOOD READ AND SA VE THESE INSTRUCTIONS W ARNING: - T O REDUCE THE RISK OF A RANGE T OP GREASE FIRE : Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always turn hood ON ...

  • Faber Remote Blower - page 4

    4 EN This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever necessary . A UL Listed, 1/2" con duit connector must be provided at each end of the power supply cable (a ...

  • Faber Remote Blower - page 5

    5 EN 1 3 4 5 10 11 12 13 G E F D C A 2 CHARACTERISTICS Components Q.ty 1 1 Hood Body , complete with: Blower, Filters, Controls 2 1 Built-in hood body case 3 1 Rear remote motor connection panel 4 1 T op air outlet flange with valve 5 1 T op air outlet plug 10 1 Light 11 4 Support arms 12 2 Bush masking plug 13 2 Arm support bush A 10 Screws 3,5 x ...

  • Faber Remote Blower - page 6

    6 EN Dimensional chart - Hood Distance from the Hob ...

  • Faber Remote Blower - page 7

    7 EN Dimensional chart - LIGHT ...

  • Faber Remote Blower - page 8

    8 EN INST ALLA TION The hood can be installed in the following ways: top air outlet, bottom air outlet, rear air outlet. Once the desired configuration has been chosen (see the diagrams below) it will be necessary to provide an opening in the wall where to house the built-in hood body case. Besides the air ducting pipes, basing on the chosen config ...

  • Faber Remote Blower - page 9

    9 EN LIGHTING UNIT INST ALLA TION SCHEME LIGHTING UNIT LOWER BORDER SHALL BE INST ALLED A T THE MINIMUM DIST ANCE OF 34 9/16 IN. ABOVE THE COOKING SURF ACE. W ith the aid of the drilling template provided mark the necessary holes and drill them. ø15/16 TO P OR BOTTOM AIR OUTLET CONFIGURA TION The hood is manufactured with the air outlet at the top ...

  • Faber Remote Blower - page 10

    10 EN REAR AIR OUTLET CONFIGURA TION • Remove the suction panel by unfastening the 8 screws around the frame. • Remove the metal grease filters. • Remove the metal profile fixed to the flange by unfastening the 5 screws. • Fit the air outlet plug into the top air outlet. • Remove the rear air outlet plug . Built-in hood body case installa ...

  • Faber Remote Blower - page 11

    11 EN Hood body installation • In case of the bottom air outlet configuration the hood body has to be turned 180°. • Remove the top cover of the terminal box by unfastening the two screws fixing it to the hood casing. • W ith the aid of pliers brake through a hole inside the terminal box providing thus for a passage of the electrical connect ...

  • Faber Remote Blower - page 12

    12 EN Lighting unit installation • Provide for passage of the electrical connection wires with the hood body . • Slide the top cover downwards, unfastening the two side screws and taking care not to scratch the tubular support members. • Insert the 4 plugs D into the earlier drilled holes. • Decide the height of the light; loosen the grub s ...

  • Faber Remote Blower - page 13

    13 EN Electrical connection ELECTRICAL SHOCK HAZARD • Disconnect power before making electrical connctions. • Connect ground wire to green ground screw in terminal box. ! W ARNING green ground screw hood wiring purple wiring red wiring hood wiring black wiring white wiring power supply conduit light wiring exterior blower wiring twist-on connec ...

  • Faber Remote Blower - page 14

    14 EN MAINTENANCE Grease filters CLEANING MET AL GREASE FIL TERS • Alarm signal reset • Switch off the lights and extractor motor . • Press button T3 for at least 3 seconds, until the leds start to flash. Cleaning the filters • Open the suction cover using the lever provided. • The filters are washable and must be cleaned when the Led S1 ...

  • Faber Remote Blower - page 15

    15 EN Electric Diagram Lighting LIGHT REPLACEMENT 20 W halogen light. • Extract the lamp from the Support. • Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes. ...

  • Faber Remote Blower - page 16

    436002499_02 - 041 103 ...

Производитель Faber Категория Blower

Документы, которые мы получаем от производителя устройства Faber Remote Blower мы можем разделить на несколько групп. Это в частности:
- технические чертежи Faber
- инструкции обслуживания Remote Blower
- паспорта изделия Faber
- информационные брошюры
- энергетические этикетки Faber Remote Blower
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Faber Remote Blower.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Faber Remote Blower, инструкции обслуживания, короткие инструкции или инструкции пользователя Faber Remote Blower. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Faber Remote Blower.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Faber Remote Blower, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Faber Remote Blower пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Faber Remote Blower.

Полная инструкция обслуживания Faber, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Faber Remote Blower - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Faber Remote Blower, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Faber Remote Blower, которое найдем в данном документе
3. Советы по использованию основных функций устройства Faber Remote Blower - которые должны облегчить нам первые шаги во время использования Faber Remote Blower
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Faber Remote Blower
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Faber Remote Blower в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Faber Remote Blower?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Faber Remote Blower, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Faber Remote Blower со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)