Manual de instrucciones Empire Comfort Systems SR-10T-3

24 de páginas 1.27 mb
Descargar

Pasar a la página of 24

Summary
  • Empire Comfort Systems SR-10T-3 - page 1

    INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL UNVENTED ROOM HEA TER MODELS SR-10T -3 SR-18T -3 SR-30T -3 W ARNING: If not installed, operated and main- tained in acco rdance wit h the manu facturer’s instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness. This is an u ...

  • Empire Comfort Systems SR-10T-3 - page 2

    16941-5-0907 Page 2 SECTION P AGE Important Safety Information ..................................................................................... 3 Safety Information for Users of LP Gas ..................................................................... 4 Introduction ........................................................................... ...

  • Empire Comfort Systems SR-10T-3 - page 3

    16941-5-0907 Page 3 • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of mor e than 10,000 Btu per hou r sha ll not be inst alled in a bed room or bathr oom. • Due to high temperatur es, the appliance should be located out of ...

  • Empire Comfort Systems SR-10T-3 - page 4

    16941-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the are ...

  • Empire Comfort Systems SR-10T-3 - page 5

    16941-5-0907 Page 5 *Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation. The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFP A54 defines an unconfined space as “a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m 3 per kw) of the aggregate i ...

  • Empire Comfort Systems SR-10T-3 - page 6

    16941-5-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’ s (.3KW’ s) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat ...

  • Empire Comfort Systems SR-10T-3 - page 7

    16941-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Gas Supply Check all local codes for requirements, especially for the size and type of gas supply ...

  • Empire Comfort Systems SR-10T-3 - page 8

    16941-5-0907 Page 8 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance ...

  • Empire Comfort Systems SR-10T-3 - page 9

    16941-5-0907 Page 9 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance ...

  • Empire Comfort Systems SR-10T-3 - page 10

    16941-5-0907 Page 10 Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters. 1. Remove lower louver from casing assembly (2 screws). 2. Remove reflector from casing assembly (2 screws). 3. Remove upper louver from casing assembly (2 screws). (28 mm) (300 mm) ...

  • Empire Comfort Systems SR-10T-3 - page 11

    16941-5-0907 Page 1 1 4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver , be sure the bottom lip of upper louver goes behind the heat shield. b. ...

  • Empire Comfort Systems SR-10T-3 - page 12

    16941-5-0907 Page 12 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING ...

  • Empire Comfort Systems SR-10T-3 - page 13

    16941-5-0907 Page 13 SR-10T , SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques. A few small, hairline cracks may form over the surface of the ceramic plaques or at the edges of the ceramic plaques where they have been cemented into position on the burner assemb ...

  • Empire Comfort Systems SR-10T-3 - page 14

    16941-5-0907 Page 14 The correct flame will be blue and will extend beyond the ther - mocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 13 Oxygen Depletion Sensor Pilot (Figur e 14) When the pilot has a large yellow tip flame, clean t ...

  • Empire Comfort Systems SR-10T-3 - page 15

    16941-5-0907 Page 15 Removing Pilot/Thermocouple From Main Burner Assembly Att ent ion: The ther moc oupl e CAN NOT be repl aced as an in divi dual item. Y ou must order a new pilot when replacing thermocouple. 1. T urn OFF gas supply to the heater . 2. T urn OFF electrical supply to the heater if optional blower is installed in heater . 3. Remove ...

  • Empire Comfort Systems SR-10T-3 - page 16

    16941-5-0907 Page 16 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 13347 CASING SIDE ASSEMBL Y - LEFT 2 SR-180 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBL Y - RIGHT 5 SR-1 13 V AL VE BRACKET 6 R-6563 GAS V AL VE -SIT 7 12438 TUBING - GAS V AL VE T O BURNER 8 12437 TUB ...

  • Empire Comfort Systems SR-10T-3 - page 17

    16941-5-0907 Page 17 INDEX P AR T NUMBER NUMBER DESCRIPTION SR-18T INDEX P AR T NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBL Y - LEFT 2 SR-090 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBL Y - RIGHT 5 SR-1 13 V AL VE BRACKET 6 R-6563 GAS V AL VE -SIT 7 R-2330 BURNER 8 SR-1 19 ORIFICE SHIELD 9 SR-032 PILOT BRACKET 10 R-630 ...

  • Empire Comfort Systems SR-10T-3 - page 18

    16941-5-0907 Page 18 SR-10T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 19

    16941-5-0907 Page 19 SR-18T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 20

    16941-5-0907 Page 20 SR-30T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 21

    16941-5-0907 Page 21 REFLECTOR A ND LOUVERS ARE REMOVED FROM CASING ASSEMBL Y GROUND WIRE SCRE W F AN CONTROL HEA T SHIELD CORD SET HOLE IN CASING BAC K INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is inst alled onto the wall, in order to install the optiona l blower , the heater must be removed from the wall. If heater is installed on ...

  • Empire Comfort Systems SR-10T-3 - page 22

    16941-5-0907 Page 22 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri - cal Code, ANSI/NFP A 70, if an external electrical source is utilized . This appliance is equipped with a three-pr ong [grounding] plug for your protection against sh ...

  • Empire Comfort Systems SR-10T-3 - page 23

    16941-5-0907 Page 23 SER VICE NOTES ...

  • Empire Comfort Systems SR-10T-3 - page 24

    16941-5-0907 Page 24 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

Fabricante Empire Comfort Systems Categoría Electric Heater

Los documentos del dispositivo Empire Comfort Systems SR-10T-3 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Empire Comfort Systems
- manuales de instrucciones SR-10T-3
- hojas de producto Empire Comfort Systems
- folletos informativos
- o etiquetas energéticas Empire Comfort Systems SR-10T-3
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Empire Comfort Systems SR-10T-3.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Empire Comfort Systems SR-10T-3, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Empire Comfort Systems SR-10T-3. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Empire Comfort Systems SR-10T-3.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Empire Comfort Systems SR-10T-3, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Empire Comfort Systems SR-10T-3. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Empire Comfort Systems SR-10T-3.

El manual de instrucciones completo de Empire Comfort Systems debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Empire Comfort Systems SR-10T-3 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Empire Comfort Systems SR-10T-3, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Empire Comfort Systems SR-10T-3 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Empire Comfort Systems SR-10T-3 - que deben facilitarnos los primeros pasos durante el uso de Empire Comfort Systems SR-10T-3
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Empire Comfort Systems SR-10T-3
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Empire Comfort Systems SR-10T-3 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Empire Comfort Systems SR-10T-3?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Empire Comfort Systems SR-10T-3, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Empire Comfort Systems SR-10T-3 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)