    INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL UNVENTED ROOM HEA TER MODELS SR-10T -3 SR-18T -3 SR-30T -3 W ARNING: If not installed, operated and main- tained in acco rdance wit h the manu facturer’s instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness. This is an u ...

  • Empire Comfort Systems SR-10T-3 - page 2

    16941-5-0907 Page 2 SECTION P AGE Important Safety Information ..................................................................................... 3 Safety Information for Users of LP Gas ..................................................................... 4 Introduction ........................................................................... ...

  • Empire Comfort Systems SR-10T-3 - page 3

    16941-5-0907 Page 3 • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of mor e than 10,000 Btu per hou r sha ll not be inst alled in a bed room or bathr oom. • Due to high temperatur es, the appliance should be located out of ...

  • Empire Comfort Systems SR-10T-3 - page 4

    16941-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the are ...

  • Empire Comfort Systems SR-10T-3 - page 5

    16941-5-0907 Page 5 *Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation. The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFP A54 defines an unconfined space as “a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m 3 per kw) of the aggregate i ...

  • Empire Comfort Systems SR-10T-3 - page 6

    16941-5-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’ s (.3KW’ s) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat ...

  • Empire Comfort Systems SR-10T-3 - page 7

    16941-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Gas Supply Check all local codes for requirements, especially for the size and type of gas supply ...

  • Empire Comfort Systems SR-10T-3 - page 8

    16941-5-0907 Page 8 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance ...

  • Empire Comfort Systems SR-10T-3 - page 9

    16941-5-0907 Page 9 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance ...

  • Empire Comfort Systems SR-10T-3 - page 10

    16941-5-0907 Page 10 Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters. 1. Remove lower louver from casing assembly (2 screws). 2. Remove reflector from casing assembly (2 screws). 3. Remove upper louver from casing assembly (2 screws). (28 mm) (300 mm) ...

  • Empire Comfort Systems SR-10T-3 - page 11

    16941-5-0907 Page 1 1 4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver , be sure the bottom lip of upper louver goes behind the heat shield. b. ...

  • Empire Comfort Systems SR-10T-3 - page 12

    16941-5-0907 Page 12 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING ...

  • Empire Comfort Systems SR-10T-3 - page 13

    16941-5-0907 Page 13 SR-10T , SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques. A few small, hairline cracks may form over the surface of the ceramic plaques or at the edges of the ceramic plaques where they have been cemented into position on the burner assemb ...

  • Empire Comfort Systems SR-10T-3 - page 14

    16941-5-0907 Page 14 The correct flame will be blue and will extend beyond the ther - mocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 13 Oxygen Depletion Sensor Pilot (Figur e 14) When the pilot has a large yellow tip flame, clean t ...

  • Empire Comfort Systems SR-10T-3 - page 15

    16941-5-0907 Page 15 Removing Pilot/Thermocouple From Main Burner Assembly Att ent ion: The ther moc oupl e CAN NOT be repl aced as an in divi dual item. Y ou must order a new pilot when replacing thermocouple. 1. T urn OFF gas supply to the heater . 2. T urn OFF electrical supply to the heater if optional blower is installed in heater . 3. Remove ...

  • Empire Comfort Systems SR-10T-3 - page 16

    16941-5-0907 Page 16 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 13347 CASING SIDE ASSEMBL Y - LEFT 2 SR-180 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBL Y - RIGHT 5 SR-1 13 V AL VE BRACKET 6 R-6563 GAS V AL VE -SIT 7 12438 TUBING - GAS V AL VE T O BURNER 8 12437 TUB ...

  • Empire Comfort Systems SR-10T-3 - page 17

    16941-5-0907 Page 17 INDEX P AR T NUMBER NUMBER DESCRIPTION SR-18T INDEX P AR T NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBL Y - LEFT 2 SR-090 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBL Y - RIGHT 5 SR-1 13 V AL VE BRACKET 6 R-6563 GAS V AL VE -SIT 7 R-2330 BURNER 8 SR-1 19 ORIFICE SHIELD 9 SR-032 PILOT BRACKET 10 R-630 ...

  • Empire Comfort Systems SR-10T-3 - page 18

    16941-5-0907 Page 18 SR-10T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 19

    16941-5-0907 Page 19 SR-18T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 20

    16941-5-0907 Page 20 SR-30T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 21

    16941-5-0907 Page 21 REFLECTOR A ND LOUVERS ARE REMOVED FROM CASING ASSEMBL Y GROUND WIRE SCRE W F AN CONTROL HEA T SHIELD CORD SET HOLE IN CASING BAC K INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is inst alled onto the wall, in order to install the optiona l blower , the heater must be removed from the wall. If heater is installed on ...

  • Empire Comfort Systems SR-10T-3 - page 22

    16941-5-0907 Page 22 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri - cal Code, ANSI/NFP A 70, if an external electrical source is utilized . This appliance is equipped with a three-pr ong [grounding] plug for your protection against sh ...

  • Empire Comfort Systems SR-10T-3 - page 23

    16941-5-0907 Page 23 SER VICE NOTES ...

  • Empire Comfort Systems SR-10T-3 - page 24

    16941-5-0907 Page 24 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

メーカー Empire Comfort Systems カテゴリー Electric Heater

Empire Comfort Systems SR-10T-3のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SR-10T-3の取扱説明書
- Empire Comfort Systemsの製品カード
- パンフレット
- またはEmpire Comfort Systems SR-10T-3の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Empire Comfort Systems SR-10T-3の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Empire Comfort Systems SR-10T-3の取り付け説明書、サービスマニュアル、簡易説明書、またはEmpire Comfort Systems SR-10T-3のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Empire Comfort Systems SR-10T-3の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Empire Comfort Systems SR-10T-3デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmpire Comfort Systems SR-10T-3を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmpire Comfort Systems SR-10T-3ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Empire Comfort Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Empire Comfort Systems SR-10T-3の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmpire Comfort Systems SR-10T-3の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Empire Comfort Systems SR-10T-3に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Empire Comfort Systems SR-10T-3デバイスの基本機能を使うにあたってのヒント。 Empire Comfort Systems SR-10T-3のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Empire Comfort Systems SR-10T-3に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmpire Comfort Systems SR-10T-3のメーカー/サービスへの連絡先に関する情報。

Empire Comfort Systems SR-10T-3についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmpire Comfort Systems SR-10T-3の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmpire Comfort Systems SR-10T-3で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)