    INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL UNVENTED ROOM HEA TER MODELS SR-10T -3 SR-18T -3 SR-30T -3 W ARNING: If not installed, operated and main- tained in acco rdance wit h the manu facturer’s instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness. This is an u ...

  • Empire Comfort Systems SR-10T-3 - page 2

    16941-5-0907 Page 2 SECTION P AGE Important Safety Information ..................................................................................... 3 Safety Information for Users of LP Gas ..................................................................... 4 Introduction ........................................................................... ...

  • Empire Comfort Systems SR-10T-3 - page 3

    16941-5-0907 Page 3 • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of mor e than 10,000 Btu per hou r sha ll not be inst alled in a bed room or bathr oom. • Due to high temperatur es, the appliance should be located out of ...

  • Empire Comfort Systems SR-10T-3 - page 4

    16941-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the are ...

  • Empire Comfort Systems SR-10T-3 - page 5

    16941-5-0907 Page 5 *Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation. The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFP A54 defines an unconfined space as “a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m 3 per kw) of the aggregate i ...

  • Empire Comfort Systems SR-10T-3 - page 6

    16941-5-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’ s (.3KW’ s) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat ...

  • Empire Comfort Systems SR-10T-3 - page 7

    16941-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Gas Supply Check all local codes for requirements, especially for the size and type of gas supply ...

  • Empire Comfort Systems SR-10T-3 - page 8

    16941-5-0907 Page 8 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance ...

  • Empire Comfort Systems SR-10T-3 - page 9

    16941-5-0907 Page 9 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance ...

  • Empire Comfort Systems SR-10T-3 - page 10

    16941-5-0907 Page 10 Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters. 1. Remove lower louver from casing assembly (2 screws). 2. Remove reflector from casing assembly (2 screws). 3. Remove upper louver from casing assembly (2 screws). (28 mm) (300 mm) ...

  • Empire Comfort Systems SR-10T-3 - page 11

    16941-5-0907 Page 1 1 4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver , be sure the bottom lip of upper louver goes behind the heat shield. b. ...

  • Empire Comfort Systems SR-10T-3 - page 12

    16941-5-0907 Page 12 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING ...

  • Empire Comfort Systems SR-10T-3 - page 13

    16941-5-0907 Page 13 SR-10T , SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques. A few small, hairline cracks may form over the surface of the ceramic plaques or at the edges of the ceramic plaques where they have been cemented into position on the burner assemb ...

  • Empire Comfort Systems SR-10T-3 - page 14

    16941-5-0907 Page 14 The correct flame will be blue and will extend beyond the ther - mocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 13 Oxygen Depletion Sensor Pilot (Figur e 14) When the pilot has a large yellow tip flame, clean t ...

  • Empire Comfort Systems SR-10T-3 - page 15

    16941-5-0907 Page 15 Removing Pilot/Thermocouple From Main Burner Assembly Att ent ion: The ther moc oupl e CAN NOT be repl aced as an in divi dual item. Y ou must order a new pilot when replacing thermocouple. 1. T urn OFF gas supply to the heater . 2. T urn OFF electrical supply to the heater if optional blower is installed in heater . 3. Remove ...

  • Empire Comfort Systems SR-10T-3 - page 16

    16941-5-0907 Page 16 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 13347 CASING SIDE ASSEMBL Y - LEFT 2 SR-180 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBL Y - RIGHT 5 SR-1 13 V AL VE BRACKET 6 R-6563 GAS V AL VE -SIT 7 12438 TUBING - GAS V AL VE T O BURNER 8 12437 TUB ...

  • Empire Comfort Systems SR-10T-3 - page 17

    16941-5-0907 Page 17 INDEX P AR T NUMBER NUMBER DESCRIPTION SR-18T INDEX P AR T NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBL Y - LEFT 2 SR-090 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBL Y - RIGHT 5 SR-1 13 V AL VE BRACKET 6 R-6563 GAS V AL VE -SIT 7 R-2330 BURNER 8 SR-1 19 ORIFICE SHIELD 9 SR-032 PILOT BRACKET 10 R-630 ...

  • Empire Comfort Systems SR-10T-3 - page 18

    16941-5-0907 Page 18 SR-10T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 19

    16941-5-0907 Page 19 SR-18T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 20

    16941-5-0907 Page 20 SR-30T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 21

    16941-5-0907 Page 21 REFLECTOR A ND LOUVERS ARE REMOVED FROM CASING ASSEMBL Y GROUND WIRE SCRE W F AN CONTROL HEA T SHIELD CORD SET HOLE IN CASING BAC K INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is inst alled onto the wall, in order to install the optiona l blower , the heater must be removed from the wall. If heater is installed on ...

  • Empire Comfort Systems SR-10T-3 - page 22

    16941-5-0907 Page 22 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri - cal Code, ANSI/NFP A 70, if an external electrical source is utilized . This appliance is equipped with a three-pr ong [grounding] plug for your protection against sh ...

  • Empire Comfort Systems SR-10T-3 - page 23

    16941-5-0907 Page 23 SER VICE NOTES ...

  • Empire Comfort Systems SR-10T-3 - page 24

    16941-5-0907 Page 24 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

Fabricant Empire Comfort Systems Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilEmpire Comfort Systems SR-10T-3 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Empire Comfort Systems
- manuels d’utilisations SR-10T-3
- fiches produit Empire Comfort Systems
- dépliants
- ou étiquettes-énergie Empire Comfort Systems SR-10T-3
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Empire Comfort Systems SR-10T-3.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Empire Comfort Systems SR-10T-3, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Empire Comfort Systems SR-10T-3. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Empire Comfort Systems SR-10T-3.

Manuel d’utilisation complet de l’appareil Empire Comfort Systems SR-10T-3, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Empire Comfort Systems SR-10T-3 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Empire Comfort Systems SR-10T-3.

Le manuel d’utilisation complet Empire Comfort Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Empire Comfort Systems SR-10T-3 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Empire Comfort Systems SR-10T-3, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEmpire Comfort Systems SR-10T-3 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Empire Comfort Systems SR-10T-3 - qui devraient nous aider dans les premières étapes lors de l'utilisation Empire Comfort Systems SR-10T-3
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Empire Comfort Systems SR-10T-3
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Empire Comfort Systems SR-10T-3 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Empire Comfort Systems SR-10T-3?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Empire Comfort Systems SR-10T-3, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Empire Comfort Systems SR-10T-3 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)