Manual de instrucciones Oneida Air Systems Super Dust Gorilla

21 de páginas 2.26 mb
Descargar

Pasar a la página of 21

Summary
  • Oneida Air Systems Super Dust Gorilla - page 1

    Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Shown with optional bolt together Angle Iron stand. *Models may vary sligthly in appearance. GORILLA The 2 HP Cyclonic Dust Collector Owners Man ual 1/07 ...

  • Oneida Air Systems Super Dust Gorilla - page 2

    1 Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes ...

  • Oneida Air Systems Super Dust Gorilla - page 3

    2 I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely before operating collector: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician wire Fan / Blower acc ...

  • Oneida Air Systems Super Dust Gorilla - page 4

    3 II. 2hp Dust Gorilla Configurations Caution: If exhaust air is vented outside you must provide make up / return air . Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. 1. External Cartridge Filter - Silencer Included with Filter 1. External Cartridge Filter 2HP Super Dust Gorilla Owner s ...

  • Oneida Air Systems Super Dust Gorilla - page 5

    III. General Specifications & Fan Per formance Cur ves 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 4 - Sleeve kit adds 7 (4 is minimum) - 35 gal. bin is 22 dia. x 22.5 h / 55 gal. bin is 22 dia. x 35.5 h - Several Filter Options Available- Galvanized steel construction - The collector can be hung on the wall, from t ...

  • Oneida Air Systems Super Dust Gorilla - page 6

    5 IV . Dimensions For Minimum Mounting Heights w/ 39 Filter . *Dimensions subject to slight variation in manufacturing. 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 91.00 Dimens ions s hown with 2" f lex hose between dru m and co ne col la rs 66.50 75.50 35 Gal Shown Add 13 " fo r 55 Gal 26.34 42.5 56.00 GORILLA The TM 24.25 ...

  • Oneida Air Systems Super Dust Gorilla - page 7

    2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 6 V . General Assembly 1. Motor Assembly - BXI002105 1a. 2 hp Motor - BMZ020105 1b. Magnetic Starter w/ Remote Option - AMR221 1 14 1c. Cord Connector - WCC025038 1d. Cord Connector Lock Nut - WCN120000 1e. Fan Wheel - BWX142578 1f. Motor Plate - RMP002105 2. Fan Housing - BHX030005 3. Cyclone ...

  • Oneida Air Systems Super Dust Gorilla - page 8

    7 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c VI. General Assembly Instructions Cyclone Barrel Cyclone Cone 2. Cyclone Barrel Air Inlet Fan / Blower Housing Before you start, make sure you have cut and placed the provided gasket material on top and bottom of the Fan/Blower housing and the Cone as shown in the diagrams. Then determine whi ...

  • Oneida Air Systems Super Dust Gorilla - page 9

    8 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c VII. Bracket Assembly 1. Y ou must determine the direction the fan outlet will point to proceed with this mounting assembly . The collector will seem quieter if the outlet is aimed away from the area people tend to work. Slots in the bracket s are .406 x 1.00 Note: Bolts included to mou ...

  • Oneida Air Systems Super Dust Gorilla - page 10

    VIII. Filter Assembly 9 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c Note: Do not return exhaust air to the shop unless filter media is added. External 39 Filter Assembly 1. Attach cartridge with hardware provided making sure gasket is attached. See Fig. 1 2. If Filter requires additional support. Use the plate at the top of the filter ...

  • Oneida Air Systems Super Dust Gorilla - page 11

    10 IX . Filter Maintenance External Filter Cartridge Cleaning Intervals Caution: Fine dust collected in filter is hazardous to your health! Do not breathe! When unit is turned of f, use compressed air to blow dust off from exterior of filter . Hold nozzle at least 8 away from filter pleats*. Do not remove bottom dust pan before or during the blo ...

  • Oneida Air Systems Super Dust Gorilla - page 12

    11 X . Directions for Cleaning External Filter 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c The External Filter can be cleaned using the following methods: W ait a few minutes for internal dust to settle then unclip and carefully empty dust bin. Keep nozzle at least 6 from filter and keep your pressure down. Closer blasts may damage fi ...

  • Oneida Air Systems Super Dust Gorilla - page 13

    Motor Baldor 2hp Catalog #VL3515T 12 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XI. Wiring Diagram for Magnetic Star ter (220v , 1 ** )* *S tarter will not operate at any other voltages. **S tarter is shown configured for 1O but can also be used for 2hp, 3O motors. Always use a licensed, professional electrician. Open access cover on th ...

  • Oneida Air Systems Super Dust Gorilla - page 14

    Unplug unit before servicing or cleaning. 13 XII. Troubleshooting 13 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c ...

  • Oneida Air Systems Super Dust Gorilla - page 15

    XIII. Fire Hazards - Read Before Installing and Operating Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust collector . Personnel should keep at least 20 feet away ...

  • Oneida Air Systems Super Dust Gorilla - page 16

    XIV . T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive conceale ...

  • Oneida Air Systems Super Dust Gorilla - page 17

    16 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XV . Stand Assembly Included Hardware: (32) 5/16 x 1 Bolts - AFB155190 (32) 5/16 Nuts - AFW180000 (64) 5/16 Flat W ashers - AFT155175 23 7/8 23 7/8 23 7/8 21 3/4 21 3/4 21 3/4 21 3/4 56 Bolt W ashers S tand Nut FRONT has no lower brace across. The two triangular sl ...

  • Oneida Air Systems Super Dust Gorilla - page 18

    2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XVI. Accessories 56 25 25 Bolt T ogether Angle Iron S tand STG021035 - 35 gal. S tand STG021055 - 55 gal. S tand Replacement Filter FCS133900 Dust Containers 35 gal. Fiber 55 gal. Fiber 55 gal. S teel ABX000000 Kit Contents: 8 Ft. Hose and Connection 0 1 2 3 4 5 INCHES W.C. Gauge Brack ...

  • Oneida Air Systems Super Dust Gorilla - page 19

    18 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XVII. Fan Motor Maintenance Per Baldor specifications, their 2 pole motors (3600 RPM) motors are to be relubricated every 5500 hours. T able 1 - Service Conditions T able 2 - Lubrication Interval Multiplier Per Baldor specifications, add .30 ounces (8.4 grams) of Mobil Polyrex grease by weig ...

  • Oneida Air Systems Super Dust Gorilla - page 20

    19 2HP Dust Gorilla Owner s Manual O.A.S. 2007 c Retrofit (Wiring) of Wireless Remote into 220V Control Circuit of Square D / T elemecanique Mag Starters Remote Black Box 6T3 4T2 2T1 A2 A1 13NO 5L3 3L2 1L1 Contactor Overload 98 97 95 96 Amp Adjustment Dial YEL BRN BRN YEL RED RED RED RED Wire Nuts Start Stop Start / Stop Push Button Assemb ...

  • Oneida Air Systems Super Dust Gorilla - page 21

    20 2HP Dust Gorilla Owner s Manual O.A.S. 2007 c Optional - XIX . Filter Efficiency Gauge Mounting Instructions Can be attached up to 8 away . OR Air Flow to Filter Mounting Instructions 1. Mount brass static pressure tube in plenum with tip pointed into the air stream. Use mounting bracket and sheet metal screws if interior of plenum is not ...

Fabricante Oneida Air Systems Categoría Dust Collector

Los documentos del dispositivo Oneida Air Systems Super Dust Gorilla que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Oneida Air Systems
- manuales de instrucciones Super Dust Gorilla
- hojas de producto Oneida Air Systems
- folletos informativos
- o etiquetas energéticas Oneida Air Systems Super Dust Gorilla
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Oneida Air Systems Super Dust Gorilla.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Oneida Air Systems Super Dust Gorilla, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Oneida Air Systems Super Dust Gorilla. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Oneida Air Systems Super Dust Gorilla.

El manual de instrucciones del dispositivo Oneida Air Systems Super Dust Gorilla, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Oneida Air Systems Super Dust Gorilla. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Oneida Air Systems Super Dust Gorilla.

El manual de instrucciones completo de Oneida Air Systems debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Oneida Air Systems Super Dust Gorilla - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Oneida Air Systems Super Dust Gorilla, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Oneida Air Systems Super Dust Gorilla que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Oneida Air Systems Super Dust Gorilla - que deben facilitarnos los primeros pasos durante el uso de Oneida Air Systems Super Dust Gorilla
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Oneida Air Systems Super Dust Gorilla
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Oneida Air Systems Super Dust Gorilla en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Oneida Air Systems Super Dust Gorilla?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Oneida Air Systems Super Dust Gorilla, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Oneida Air Systems Super Dust Gorilla probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)