    Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Shown with optional bolt together Angle Iron stand. *Models may vary sligthly in appearance. GORILLA The 2 HP Cyclonic Dust Collector Owners Man ual 1/07 ...

  • Oneida Air Systems Super Dust Gorilla - page 2

    1 Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes ...

  • Oneida Air Systems Super Dust Gorilla - page 3

    2 I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely before operating collector: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician wire Fan / Blower acc ...

  • Oneida Air Systems Super Dust Gorilla - page 4

    3 II. 2hp Dust Gorilla Configurations Caution: If exhaust air is vented outside you must provide make up / return air . Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. 1. External Cartridge Filter - Silencer Included with Filter 1. External Cartridge Filter 2HP Super Dust Gorilla Owner s ...

  • Oneida Air Systems Super Dust Gorilla - page 5

    III. General Specifications & Fan Per formance Cur ves 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 4 - Sleeve kit adds 7 (4 is minimum) - 35 gal. bin is 22 dia. x 22.5 h / 55 gal. bin is 22 dia. x 35.5 h - Several Filter Options Available- Galvanized steel construction - The collector can be hung on the wall, from t ...

  • Oneida Air Systems Super Dust Gorilla - page 6

    5 IV . Dimensions For Minimum Mounting Heights w/ 39 Filter . *Dimensions subject to slight variation in manufacturing. 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 91.00 Dimens ions s hown with 2" f lex hose between dru m and co ne col la rs 66.50 75.50 35 Gal Shown Add 13 " fo r 55 Gal 26.34 42.5 56.00 GORILLA The TM 24.25 ...

  • Oneida Air Systems Super Dust Gorilla - page 7

    2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 6 V . General Assembly 1. Motor Assembly - BXI002105 1a. 2 hp Motor - BMZ020105 1b. Magnetic Starter w/ Remote Option - AMR221 1 14 1c. Cord Connector - WCC025038 1d. Cord Connector Lock Nut - WCN120000 1e. Fan Wheel - BWX142578 1f. Motor Plate - RMP002105 2. Fan Housing - BHX030005 3. Cyclone ...

  • Oneida Air Systems Super Dust Gorilla - page 8

    7 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c VI. General Assembly Instructions Cyclone Barrel Cyclone Cone 2. Cyclone Barrel Air Inlet Fan / Blower Housing Before you start, make sure you have cut and placed the provided gasket material on top and bottom of the Fan/Blower housing and the Cone as shown in the diagrams. Then determine whi ...

  • Oneida Air Systems Super Dust Gorilla - page 9

    8 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c VII. Bracket Assembly 1. Y ou must determine the direction the fan outlet will point to proceed with this mounting assembly . The collector will seem quieter if the outlet is aimed away from the area people tend to work. Slots in the bracket s are .406 x 1.00 Note: Bolts included to mou ...

  • Oneida Air Systems Super Dust Gorilla - page 10

    VIII. Filter Assembly 9 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c Note: Do not return exhaust air to the shop unless filter media is added. External 39 Filter Assembly 1. Attach cartridge with hardware provided making sure gasket is attached. See Fig. 1 2. If Filter requires additional support. Use the plate at the top of the filter ...

  • Oneida Air Systems Super Dust Gorilla - page 11

    10 IX . Filter Maintenance External Filter Cartridge Cleaning Intervals Caution: Fine dust collected in filter is hazardous to your health! Do not breathe! When unit is turned of f, use compressed air to blow dust off from exterior of filter . Hold nozzle at least 8 away from filter pleats*. Do not remove bottom dust pan before or during the blo ...

  • Oneida Air Systems Super Dust Gorilla - page 12

    11 X . Directions for Cleaning External Filter 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c The External Filter can be cleaned using the following methods: W ait a few minutes for internal dust to settle then unclip and carefully empty dust bin. Keep nozzle at least 6 from filter and keep your pressure down. Closer blasts may damage fi ...

  • Oneida Air Systems Super Dust Gorilla - page 13

    Motor Baldor 2hp Catalog #VL3515T 12 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XI. Wiring Diagram for Magnetic Star ter (220v , 1 ** )* *S tarter will not operate at any other voltages. **S tarter is shown configured for 1O but can also be used for 2hp, 3O motors. Always use a licensed, professional electrician. Open access cover on th ...

  • Oneida Air Systems Super Dust Gorilla - page 14

    Unplug unit before servicing or cleaning. 13 XII. Troubleshooting 13 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c ...

  • Oneida Air Systems Super Dust Gorilla - page 15

    XIII. Fire Hazards - Read Before Installing and Operating Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust collector . Personnel should keep at least 20 feet away ...

  • Oneida Air Systems Super Dust Gorilla - page 16

    XIV . T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive conceale ...

  • Oneida Air Systems Super Dust Gorilla - page 17

    16 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XV . Stand Assembly Included Hardware: (32) 5/16 x 1 Bolts - AFB155190 (32) 5/16 Nuts - AFW180000 (64) 5/16 Flat W ashers - AFT155175 23 7/8 23 7/8 23 7/8 21 3/4 21 3/4 21 3/4 21 3/4 56 Bolt W ashers S tand Nut FRONT has no lower brace across. The two triangular sl ...

  • Oneida Air Systems Super Dust Gorilla - page 18

    2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XVI. Accessories 56 25 25 Bolt T ogether Angle Iron S tand STG021035 - 35 gal. S tand STG021055 - 55 gal. S tand Replacement Filter FCS133900 Dust Containers 35 gal. Fiber 55 gal. Fiber 55 gal. S teel ABX000000 Kit Contents: 8 Ft. Hose and Connection 0 1 2 3 4 5 INCHES W.C. Gauge Brack ...

  • Oneida Air Systems Super Dust Gorilla - page 19

    18 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XVII. Fan Motor Maintenance Per Baldor specifications, their 2 pole motors (3600 RPM) motors are to be relubricated every 5500 hours. T able 1 - Service Conditions T able 2 - Lubrication Interval Multiplier Per Baldor specifications, add .30 ounces (8.4 grams) of Mobil Polyrex grease by weig ...

  • Oneida Air Systems Super Dust Gorilla - page 20

    19 2HP Dust Gorilla Owner s Manual O.A.S. 2007 c Retrofit (Wiring) of Wireless Remote into 220V Control Circuit of Square D / T elemecanique Mag Starters Remote Black Box 6T3 4T2 2T1 A2 A1 13NO 5L3 3L2 1L1 Contactor Overload 98 97 95 96 Amp Adjustment Dial YEL BRN BRN YEL RED RED RED RED Wire Nuts Start Stop Start / Stop Push Button Assemb ...

  • Oneida Air Systems Super Dust Gorilla - page 21

    20 2HP Dust Gorilla Owner s Manual O.A.S. 2007 c Optional - XIX . Filter Efficiency Gauge Mounting Instructions Can be attached up to 8 away . OR Air Flow to Filter Mounting Instructions 1. Mount brass static pressure tube in plenum with tip pointed into the air stream. Use mounting bracket and sheet metal screws if interior of plenum is not ...

Fabbricante Oneida Air Systems Categoria Dust Collector

I documenti che otteniamo dal fabbricante del dispositivoOneida Air Systems Super Dust Gorilla possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Oneida Air Systems
- manuali per l’uso Super Dust Gorilla
- schede prodotto Oneida Air Systems
- opuscoli
- o etichette energetiche Oneida Air Systems Super Dust Gorilla
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Oneida Air Systems Super Dust Gorilla.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Oneida Air Systems Super Dust Gorilla, manuali di manutenzione, brevi manuali o manuali utente Oneida Air Systems Super Dust Gorilla. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Oneida Air Systems Super Dust Gorilla.

Manuale completo del dispositivo Oneida Air Systems Super Dust Gorilla, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Oneida Air Systems Super Dust Gorilla dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Oneida Air Systems Super Dust Gorilla.

Il manuale per l’uso completo Oneida Air Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Oneida Air Systems Super Dust Gorilla - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Oneida Air Systems Super Dust Gorilla, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Oneida Air Systems Super Dust Gorilla che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Oneida Air Systems Super Dust Gorilla - che ci dovrebbe aiutare nei primi passi durante l'uso Oneida Air Systems Super Dust Gorilla
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Oneida Air Systems Super Dust Gorilla
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Oneida Air Systems Super Dust Gorilla in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Oneida Air Systems Super Dust Gorilla?

Utilizza il modulo sottostante

Se non hai risolto il problema con Oneida Air Systems Super Dust Gorilla con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Oneida Air Systems Super Dust Gorilla è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)