  • Oneida Air Systems 10 HP - page 1

    10 HP NYB Pulley/Belt Drive Cyclonic Dust Collectors Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Owners Man ual ...

  • Oneida Air Systems 10 HP - page 2

    Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes, ...

  • Oneida Air Systems 10 HP - page 3

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician ...

  • Oneida Air Systems 10 HP - page 4

    II. 10hp Pulley Drive Configurations 1. No Filter - V ent Outside - Caution: If exhaust air is vented outside you must provide make up / return air . Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. 1. No Filter 2. External Cartridge Filters 3. External Tube Filters O.A.S. 2007 c 10HP Pulley ...

  • Oneida Air Systems 10 HP - page 5

    III. General Specifications & Fan Per formance Cur ves 4 10hp Fan Cur ves O.A.S. 2007 c 10 HP Industrial Systems Owner s Manual Full welded exterior Main body , cone and inlet: 16 ga. galv . Flanged 12 dia. Inlet; Flanged 13 dia. Outlet 80 high 14 rolled steel flange discharge 36 dia. rolled steel flange for mounting Cyclone C ...

  • Oneida Air Systems 10 HP - page 6

    IV . Dimensions 5 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual T op V iew Dimensions - Largest Configuration 1 1/2 Flange w/ Bolt Holes 34 10hp - 229 14 10hp - 83 30 42 17 80 Approx. 18 36 14 39 36 8 39 32.5 55 Gal. 42 10 12 8 10hp - 10 tube - 83 5 Gal. Dust Buckets Not Include ...

  • Oneida Air Systems 10 HP - page 7

    IV . Dimensions 6 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual - External Cartridge Filters 17 80 Approx. 18 36 10 14 14 39 10hp - 3 filters -Single Row - 66 36 29 1/8 8 39 62 12 55 Gal. 60 T op View Dimensions - Largest Configuration 34 10hp - 212 14 10hp - 22 1 1/2 Flange w/ Bol ...

  • Oneida Air Systems 10 HP - page 8

    7 O.A.S. 2007 c 10HP Pulley Drive Owner s Manual C-3500 Cyclone Stand - Anchor Feet Securely to Floor to Prevent Tipping (4) 3/8-16 x 1 bolts for Cyclone mount (20) 3/8-16 x 1 bolts for Cross Brace mount (28) 3/8-16 x 1 bolts for T riangle Brackets (48) 3/8 flat W ashers (48) 3/8 serrated Nuts Unit should be shipped with: w/ 55 Ga ...

  • Oneida Air Systems 10 HP - page 9

    V . Configuration Examples Sleeve Kit - Sleeve-Kit 14 for C-2500 cyclone requires 16 - 18 for a single drum and 24 for 2x drums. Additional feet of flex can be purchased to make the sleeve kit longer if needed. Drum - S tandard 55 gal. steel drums are usually 35 - 36 high Oneida Air sells 55 gal. and 35 gal. fiber and steel barrels with ...

  • Oneida Air Systems 10 HP - page 10

    VI. General Assembly Instructions 9 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 1. Determine mounting height for the cyclone. - Height depends on size of Dust Bin and length of Flex Hose to Dust Bin connection. 2. Mount Angle Iron Brackets to wall using included hardware. 3. Mount Cyclone Barrel to W all Brackets. - Determine inlet orientati ...

  • Oneida Air Systems 10 HP - page 11

    VI. General Assembly Instructions 10 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 7. Set up Fan/Blower (Cont.) All moving part s must have guards to protect personnel. Safety requirement s vary , so the number and type of guards needed to meet company , local and OSHA standards must be determined and specified by the user . Never start a fan ...

  • Oneida Air Systems 10 HP - page 12

    5 gallon buckets 12 high (Not supplied with system). Can be purchased, Part No. SDS050000 or recycled joint compound bucket s or food storage containers can be used. VII. External Filter Bag Assembly Plenum Box 22 gauge galv . T ube Filters 16oz. Needle Felted Polyester 1 Micron Filtration Hose Clamps Part # - ACB120000 Hose Clamps Part # - ACB1 ...

  • Oneida Air Systems 10 HP - page 13

    XII. Fan / Blower Wiring Diagram Wiring should always be done by a licensed electrician! 10 HP Pulley Drive Owner s Manual O.A.S. 2007 c Before Operation - Before making electrical power connections, check for proper grounding of motor and application. All electrical contacts and connections must be properly insulated and enclosed. Coupling, bel ...

  • Oneida Air Systems 10 HP - page 14

    IX . Fan / Blower - Maintenance The Fan / Blower has a TEFC - tot ally enclosed fan cooled motor that can be placed outside. The fan housing is adjustable by 22 1/2 degree increment s - outlet can be oriented by adjusting bolt hole locations between the scroll and the bracket assembly . Fan blowers come as clockwise up blast from Oneida Air Systems ...

  • Oneida Air Systems 10 HP - page 15

    14 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Maintenance of Fan / Blower (Cont.) 2.) Cleanliness - Keep both the interior and exterior of the motor free from dirt, water , oil and grease. 3.) Safety - Motors should be installed, protected and fused in accordance with latest issue of National Electrical Code, NEMA S tandard Publication No. ...

  • Oneida Air Systems 10 HP - page 16

    X . Accessories O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Dust Bin Options - (Must Order Custom Cyclone Mounting S tand.) 2. Hoppers - Large capacity hoppers from .5 cu. yd. to 3 cu. yd. 3/16 reinforcing angle for added support - 3/16 plate body is 100% continuously MIG welded on inside - 3/8 rear cross brace angle (not 3/16) - ...

  • Oneida Air Systems 10 HP - page 17

    XII. Troubleshooting Motor Overheating The motor  s internal circuit breaker will trip if the motor is overheating. Air leaks between the collector and dust bin - The lid of the dust bin and the cyclone must be in place and sealed when operating the dust collector . - Make sure flex hose is not torn and the hose clamps are tight. - Check drum li ...

  • Oneida Air Systems 10 HP - page 18

    XII. Fire Hazards - Read Before Installing and Operating 17 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust col ...

  • Oneida Air Systems 10 HP - page 19

    XIII. T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive conceale ...

  • Oneida Air Systems 10 HP - page 20

    The External Filter can be cleaned using the following methods: W ait a few minutes for internal dust to settle then unclip and carefully empty dust bin. XIV . Directions for Cleaning External Filter Keep nozzle at least 6 from filter and keep your pressure down. Closer blasts may damage filter material. Rinse off INSIDE of filter . Let filter d ...

  • Oneida Air Systems 10 HP - page 21

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 20 XV . Filter Efficiency Gauge Mounting Instructions Can be attached up to 8 away . OR Air Flow to Filter Mounting Instructions 1. Mount brass static pressure tube in plenum with tip pointed into the air stream. Use mounting bracket and sheet metal screws if interior of plenum is not accessible ...

  • Oneida Air Systems 10 HP - page 22

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 21 P le as e se e comp l ete m an ufa ct u rer i ns t ruc t i o ns for mo re i nfo r m at i on. T h is supplement i s des i gn ed to aid Oneida A ir Systems cu stomers with frequentl y as k e d ques t ions. Y ou must hav e this pro duct inst alled b y a qua lified and lice nse d el ectr ici an. I m ...

  • Oneida Air Systems 10 HP - page 23

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 22 Open ac ces s cover on the over load, th en s e t t h eo v e r l o a da m p e r a g ed i a lt om a t c ht h eF L A amperage of your motor . Th e FLA v alue can be fo und o n y our mot or name pla te. B e sur e y ou ha v e the pr op er vo ltage ava i l abl e for y our S t arter s Powe r & ...

  • Oneida Air Systems 10 HP - page 24

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 23 L3 L2 L1 A1 21 13 T3 T2 T1 A2 22 14 M T3 T2 T1 96 L3 L2 L1 95 98 97 OL / SC T3 T2 T1 7 4 1 8 5 2 9 6 3 White Yel lo w Bro wn Pl ug - I n C onn ector Res et I nstall th is Ju mper fo r Sing le O Usi ng the Sa me Gaug e Wir e S i ze d & Co nnec te d t o L 1 & L2. Omit th is Wire for Si ng ...

Fabbricante Oneida Air Systems Categoria Dust Collector

I documenti che otteniamo dal fabbricante del dispositivoOneida Air Systems 10 HP possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Oneida Air Systems
- manuali per l’uso 10 HP
- schede prodotto Oneida Air Systems
- opuscoli
- o etichette energetiche Oneida Air Systems 10 HP
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Oneida Air Systems 10 HP.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Oneida Air Systems 10 HP, manuali di manutenzione, brevi manuali o manuali utente Oneida Air Systems 10 HP. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Oneida Air Systems 10 HP.

Manuale completo del dispositivo Oneida Air Systems 10 HP, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Oneida Air Systems 10 HP dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Oneida Air Systems 10 HP.

Il manuale per l’uso completo Oneida Air Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Oneida Air Systems 10 HP - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Oneida Air Systems 10 HP, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Oneida Air Systems 10 HP che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Oneida Air Systems 10 HP - che ci dovrebbe aiutare nei primi passi durante l'uso Oneida Air Systems 10 HP
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Oneida Air Systems 10 HP
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Oneida Air Systems 10 HP in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Oneida Air Systems 10 HP?

Utilizza il modulo sottostante

Se non hai risolto il problema con Oneida Air Systems 10 HP con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Oneida Air Systems 10 HP è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)