    10 HP NYB Pulley/Belt Drive Cyclonic Dust Collectors Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Owners Man ual ...

  • Oneida Air Systems 10 HP - page 2

    Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes, ...

  • Oneida Air Systems 10 HP - page 3

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician ...

  • Oneida Air Systems 10 HP - page 4

    II. 10hp Pulley Drive Configurations 1. No Filter - V ent Outside - Caution: If exhaust air is vented outside you must provide make up / return air . Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. 1. No Filter 2. External Cartridge Filters 3. External Tube Filters O.A.S. 2007 c 10HP Pulley ...

  • Oneida Air Systems 10 HP - page 5

    III. General Specifications & Fan Per formance Cur ves 4 10hp Fan Cur ves O.A.S. 2007 c 10 HP Industrial Systems Owner s Manual Full welded exterior Main body , cone and inlet: 16 ga. galv . Flanged 12 dia. Inlet; Flanged 13 dia. Outlet 80 high 14 rolled steel flange discharge 36 dia. rolled steel flange for mounting Cyclone C ...

  • Oneida Air Systems 10 HP - page 6

    IV . Dimensions 5 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual T op V iew Dimensions - Largest Configuration 1 1/2 Flange w/ Bolt Holes 34 10hp - 229 14 10hp - 83 30 42 17 80 Approx. 18 36 14 39 36 8 39 32.5 55 Gal. 42 10 12 8 10hp - 10 tube - 83 5 Gal. Dust Buckets Not Include ...

  • Oneida Air Systems 10 HP - page 7

    IV . Dimensions 6 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual - External Cartridge Filters 17 80 Approx. 18 36 10 14 14 39 10hp - 3 filters -Single Row - 66 36 29 1/8 8 39 62 12 55 Gal. 60 T op View Dimensions - Largest Configuration 34 10hp - 212 14 10hp - 22 1 1/2 Flange w/ Bol ...

  • Oneida Air Systems 10 HP - page 8

    7 O.A.S. 2007 c 10HP Pulley Drive Owner s Manual C-3500 Cyclone Stand - Anchor Feet Securely to Floor to Prevent Tipping (4) 3/8-16 x 1 bolts for Cyclone mount (20) 3/8-16 x 1 bolts for Cross Brace mount (28) 3/8-16 x 1 bolts for T riangle Brackets (48) 3/8 flat W ashers (48) 3/8 serrated Nuts Unit should be shipped with: w/ 55 Ga ...

  • Oneida Air Systems 10 HP - page 9

    V . Configuration Examples Sleeve Kit - Sleeve-Kit 14 for C-2500 cyclone requires 16 - 18 for a single drum and 24 for 2x drums. Additional feet of flex can be purchased to make the sleeve kit longer if needed. Drum - S tandard 55 gal. steel drums are usually 35 - 36 high Oneida Air sells 55 gal. and 35 gal. fiber and steel barrels with ...

  • Oneida Air Systems 10 HP - page 10

    VI. General Assembly Instructions 9 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 1. Determine mounting height for the cyclone. - Height depends on size of Dust Bin and length of Flex Hose to Dust Bin connection. 2. Mount Angle Iron Brackets to wall using included hardware. 3. Mount Cyclone Barrel to W all Brackets. - Determine inlet orientati ...

  • Oneida Air Systems 10 HP - page 11

    VI. General Assembly Instructions 10 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 7. Set up Fan/Blower (Cont.) All moving part s must have guards to protect personnel. Safety requirement s vary , so the number and type of guards needed to meet company , local and OSHA standards must be determined and specified by the user . Never start a fan ...

  • Oneida Air Systems 10 HP - page 12

    5 gallon buckets 12 high (Not supplied with system). Can be purchased, Part No. SDS050000 or recycled joint compound bucket s or food storage containers can be used. VII. External Filter Bag Assembly Plenum Box 22 gauge galv . T ube Filters 16oz. Needle Felted Polyester 1 Micron Filtration Hose Clamps Part # - ACB120000 Hose Clamps Part # - ACB1 ...

  • Oneida Air Systems 10 HP - page 13

    XII. Fan / Blower Wiring Diagram Wiring should always be done by a licensed electrician! 10 HP Pulley Drive Owner s Manual O.A.S. 2007 c Before Operation - Before making electrical power connections, check for proper grounding of motor and application. All electrical contacts and connections must be properly insulated and enclosed. Coupling, bel ...

  • Oneida Air Systems 10 HP - page 14

    IX . Fan / Blower - Maintenance The Fan / Blower has a TEFC - tot ally enclosed fan cooled motor that can be placed outside. The fan housing is adjustable by 22 1/2 degree increment s - outlet can be oriented by adjusting bolt hole locations between the scroll and the bracket assembly . Fan blowers come as clockwise up blast from Oneida Air Systems ...

  • Oneida Air Systems 10 HP - page 15

    14 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Maintenance of Fan / Blower (Cont.) 2.) Cleanliness - Keep both the interior and exterior of the motor free from dirt, water , oil and grease. 3.) Safety - Motors should be installed, protected and fused in accordance with latest issue of National Electrical Code, NEMA S tandard Publication No. ...

  • Oneida Air Systems 10 HP - page 16

    X . Accessories O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Dust Bin Options - (Must Order Custom Cyclone Mounting S tand.) 2. Hoppers - Large capacity hoppers from .5 cu. yd. to 3 cu. yd. 3/16 reinforcing angle for added support - 3/16 plate body is 100% continuously MIG welded on inside - 3/8 rear cross brace angle (not 3/16) - ...

  • Oneida Air Systems 10 HP - page 17

    XII. Troubleshooting Motor Overheating The motor  s internal circuit breaker will trip if the motor is overheating. Air leaks between the collector and dust bin - The lid of the dust bin and the cyclone must be in place and sealed when operating the dust collector . - Make sure flex hose is not torn and the hose clamps are tight. - Check drum li ...

  • Oneida Air Systems 10 HP - page 18

    XII. Fire Hazards - Read Before Installing and Operating 17 O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust col ...

  • Oneida Air Systems 10 HP - page 19

    XIII. T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive conceale ...

  • Oneida Air Systems 10 HP - page 20

    The External Filter can be cleaned using the following methods: W ait a few minutes for internal dust to settle then unclip and carefully empty dust bin. XIV . Directions for Cleaning External Filter Keep nozzle at least 6 from filter and keep your pressure down. Closer blasts may damage filter material. Rinse off INSIDE of filter . Let filter d ...

  • Oneida Air Systems 10 HP - page 21

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 20 XV . Filter Efficiency Gauge Mounting Instructions Can be attached up to 8 away . OR Air Flow to Filter Mounting Instructions 1. Mount brass static pressure tube in plenum with tip pointed into the air stream. Use mounting bracket and sheet metal screws if interior of plenum is not accessible ...

  • Oneida Air Systems 10 HP - page 22

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 21 P le as e se e comp l ete m an ufa ct u rer i ns t ruc t i o ns for mo re i nfo r m at i on. T h is supplement i s des i gn ed to aid Oneida A ir Systems cu stomers with frequentl y as k e d ques t ions. Y ou must hav e this pro duct inst alled b y a qua lified and lice nse d el ectr ici an. I m ...

  • Oneida Air Systems 10 HP - page 23

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 22 Open ac ces s cover on the over load, th en s e t t h eo v e r l o a da m p e r a g ed i a lt om a t c ht h eF L A amperage of your motor . Th e FLA v alue can be fo und o n y our mot or name pla te. B e sur e y ou ha v e the pr op er vo ltage ava i l abl e for y our S t arter s Powe r & ...

  • Oneida Air Systems 10 HP - page 24

    O.A.S. 2007 c 10 HP Pulley Drive Owner s Manual 23 L3 L2 L1 A1 21 13 T3 T2 T1 A2 22 14 M T3 T2 T1 96 L3 L2 L1 95 98 97 OL / SC T3 T2 T1 7 4 1 8 5 2 9 6 3 White Yel lo w Bro wn Pl ug - I n C onn ector Res et I nstall th is Ju mper fo r Sing le O Usi ng the Sa me Gaug e Wir e S i ze d & Co nnec te d t o L 1 & L2. Omit th is Wire for Si ng ...

Manufacturer Oneida Air Systems Category Dust Collector

Documents that we receive from a manufacturer of a Oneida Air Systems 10 HP can be divided into several groups. They are, among others:
- Oneida Air Systems technical drawings
- 10 HP manuals
- Oneida Air Systems product data sheets
- information booklets
- or energy labels Oneida Air Systems 10 HP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oneida Air Systems 10 HP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oneida Air Systems 10 HP, service manual, brief instructions and user manuals Oneida Air Systems 10 HP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oneida Air Systems 10 HP.

A complete manual for the device Oneida Air Systems 10 HP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oneida Air Systems 10 HP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oneida Air Systems 10 HP.

A complete Oneida Air Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oneida Air Systems 10 HP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oneida Air Systems 10 HP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oneida Air Systems 10 HP, that we can find in the current document
3. Tips how to use the basic functions of the device Oneida Air Systems 10 HP - which should help us in our first steps of using Oneida Air Systems 10 HP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oneida Air Systems 10 HP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oneida Air Systems 10 HP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oneida Air Systems 10 HP?

Use the form below

If you did not solve your problem by using a manual Oneida Air Systems 10 HP, ask a question using the form below. If a user had a similar problem with Oneida Air Systems 10 HP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)