Manual Oneida Air Systems Super Dust Gorilla

21 pages 2.26 mb
Download

Go to site of 21

Summary
  • Oneida Air Systems Super Dust Gorilla - page 1

    Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Shown with optional bolt together Angle Iron stand. *Models may vary sligthly in appearance. GORILLA The 2 HP Cyclonic Dust Collector Owners Man ual 1/07 ...

  • Oneida Air Systems Super Dust Gorilla - page 2

    1 Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes ...

  • Oneida Air Systems Super Dust Gorilla - page 3

    2 I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely before operating collector: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician wire Fan / Blower acc ...

  • Oneida Air Systems Super Dust Gorilla - page 4

    3 II. 2hp Dust Gorilla Configurations Caution: If exhaust air is vented outside you must provide make up / return air . Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. 1. External Cartridge Filter - Silencer Included with Filter 1. External Cartridge Filter 2HP Super Dust Gorilla Owner s ...

  • Oneida Air Systems Super Dust Gorilla - page 5

    III. General Specifications & Fan Per formance Cur ves 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 4 - Sleeve kit adds 7 (4 is minimum) - 35 gal. bin is 22 dia. x 22.5 h / 55 gal. bin is 22 dia. x 35.5 h - Several Filter Options Available- Galvanized steel construction - The collector can be hung on the wall, from t ...

  • Oneida Air Systems Super Dust Gorilla - page 6

    5 IV . Dimensions For Minimum Mounting Heights w/ 39 Filter . *Dimensions subject to slight variation in manufacturing. 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 91.00 Dimens ions s hown with 2" f lex hose between dru m and co ne col la rs 66.50 75.50 35 Gal Shown Add 13 " fo r 55 Gal 26.34 42.5 56.00 GORILLA The TM 24.25 ...

  • Oneida Air Systems Super Dust Gorilla - page 7

    2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c 6 V . General Assembly 1. Motor Assembly - BXI002105 1a. 2 hp Motor - BMZ020105 1b. Magnetic Starter w/ Remote Option - AMR221 1 14 1c. Cord Connector - WCC025038 1d. Cord Connector Lock Nut - WCN120000 1e. Fan Wheel - BWX142578 1f. Motor Plate - RMP002105 2. Fan Housing - BHX030005 3. Cyclone ...

  • Oneida Air Systems Super Dust Gorilla - page 8

    7 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c VI. General Assembly Instructions Cyclone Barrel Cyclone Cone 2. Cyclone Barrel Air Inlet Fan / Blower Housing Before you start, make sure you have cut and placed the provided gasket material on top and bottom of the Fan/Blower housing and the Cone as shown in the diagrams. Then determine whi ...

  • Oneida Air Systems Super Dust Gorilla - page 9

    8 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c VII. Bracket Assembly 1. Y ou must determine the direction the fan outlet will point to proceed with this mounting assembly . The collector will seem quieter if the outlet is aimed away from the area people tend to work. Slots in the bracket s are .406 x 1.00 Note: Bolts included to mou ...

  • Oneida Air Systems Super Dust Gorilla - page 10

    VIII. Filter Assembly 9 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c Note: Do not return exhaust air to the shop unless filter media is added. External 39 Filter Assembly 1. Attach cartridge with hardware provided making sure gasket is attached. See Fig. 1 2. If Filter requires additional support. Use the plate at the top of the filter ...

  • Oneida Air Systems Super Dust Gorilla - page 11

    10 IX . Filter Maintenance External Filter Cartridge Cleaning Intervals Caution: Fine dust collected in filter is hazardous to your health! Do not breathe! When unit is turned of f, use compressed air to blow dust off from exterior of filter . Hold nozzle at least 8 away from filter pleats*. Do not remove bottom dust pan before or during the blo ...

  • Oneida Air Systems Super Dust Gorilla - page 12

    11 X . Directions for Cleaning External Filter 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c The External Filter can be cleaned using the following methods: W ait a few minutes for internal dust to settle then unclip and carefully empty dust bin. Keep nozzle at least 6 from filter and keep your pressure down. Closer blasts may damage fi ...

  • Oneida Air Systems Super Dust Gorilla - page 13

    Motor Baldor 2hp Catalog #VL3515T 12 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XI. Wiring Diagram for Magnetic Star ter (220v , 1 ** )* *S tarter will not operate at any other voltages. **S tarter is shown configured for 1O but can also be used for 2hp, 3O motors. Always use a licensed, professional electrician. Open access cover on th ...

  • Oneida Air Systems Super Dust Gorilla - page 14

    Unplug unit before servicing or cleaning. 13 XII. Troubleshooting 13 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c ...

  • Oneida Air Systems Super Dust Gorilla - page 15

    XIII. Fire Hazards - Read Before Installing and Operating Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust collector . Personnel should keep at least 20 feet away ...

  • Oneida Air Systems Super Dust Gorilla - page 16

    XIV . T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive conceale ...

  • Oneida Air Systems Super Dust Gorilla - page 17

    16 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XV . Stand Assembly Included Hardware: (32) 5/16 x 1 Bolts - AFB155190 (32) 5/16 Nuts - AFW180000 (64) 5/16 Flat W ashers - AFT155175 23 7/8 23 7/8 23 7/8 21 3/4 21 3/4 21 3/4 21 3/4 56 Bolt W ashers S tand Nut FRONT has no lower brace across. The two triangular sl ...

  • Oneida Air Systems Super Dust Gorilla - page 18

    2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XVI. Accessories 56 25 25 Bolt T ogether Angle Iron S tand STG021035 - 35 gal. S tand STG021055 - 55 gal. S tand Replacement Filter FCS133900 Dust Containers 35 gal. Fiber 55 gal. Fiber 55 gal. S teel ABX000000 Kit Contents: 8 Ft. Hose and Connection 0 1 2 3 4 5 INCHES W.C. Gauge Brack ...

  • Oneida Air Systems Super Dust Gorilla - page 19

    18 2HP Super Dust Gorilla Owner s Manual O.A.S. 2007 c XVII. Fan Motor Maintenance Per Baldor specifications, their 2 pole motors (3600 RPM) motors are to be relubricated every 5500 hours. T able 1 - Service Conditions T able 2 - Lubrication Interval Multiplier Per Baldor specifications, add .30 ounces (8.4 grams) of Mobil Polyrex grease by weig ...

  • Oneida Air Systems Super Dust Gorilla - page 20

    19 2HP Dust Gorilla Owner s Manual O.A.S. 2007 c Retrofit (Wiring) of Wireless Remote into 220V Control Circuit of Square D / T elemecanique Mag Starters Remote Black Box 6T3 4T2 2T1 A2 A1 13NO 5L3 3L2 1L1 Contactor Overload 98 97 95 96 Amp Adjustment Dial YEL BRN BRN YEL RED RED RED RED Wire Nuts Start Stop Start / Stop Push Button Assemb ...

  • Oneida Air Systems Super Dust Gorilla - page 21

    20 2HP Dust Gorilla Owner s Manual O.A.S. 2007 c Optional - XIX . Filter Efficiency Gauge Mounting Instructions Can be attached up to 8 away . OR Air Flow to Filter Mounting Instructions 1. Mount brass static pressure tube in plenum with tip pointed into the air stream. Use mounting bracket and sheet metal screws if interior of plenum is not ...

Manufacturer Oneida Air Systems Category Dust Collector

Documents that we receive from a manufacturer of a Oneida Air Systems Super Dust Gorilla can be divided into several groups. They are, among others:
- Oneida Air Systems technical drawings
- Super Dust Gorilla manuals
- Oneida Air Systems product data sheets
- information booklets
- or energy labels Oneida Air Systems Super Dust Gorilla
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oneida Air Systems Super Dust Gorilla.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oneida Air Systems Super Dust Gorilla, service manual, brief instructions and user manuals Oneida Air Systems Super Dust Gorilla. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oneida Air Systems Super Dust Gorilla.

A complete manual for the device Oneida Air Systems Super Dust Gorilla, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oneida Air Systems Super Dust Gorilla by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oneida Air Systems Super Dust Gorilla.

A complete Oneida Air Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oneida Air Systems Super Dust Gorilla - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oneida Air Systems Super Dust Gorilla, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oneida Air Systems Super Dust Gorilla, that we can find in the current document
3. Tips how to use the basic functions of the device Oneida Air Systems Super Dust Gorilla - which should help us in our first steps of using Oneida Air Systems Super Dust Gorilla
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oneida Air Systems Super Dust Gorilla
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oneida Air Systems Super Dust Gorilla in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oneida Air Systems Super Dust Gorilla?

Use the form below

If you did not solve your problem by using a manual Oneida Air Systems Super Dust Gorilla, ask a question using the form below. If a user had a similar problem with Oneida Air Systems Super Dust Gorilla it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)