Manual Oneida Air Systems 2005c3HP

16 pages 1.19 mb
Download

Go to site of 16

Summary
  • Oneida Air Systems 2005c3HP - page 1

    3HP High Vacuum Dust Collector Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Owners Man ual ...

  • Oneida Air Systems 2005c3HP - page 2

    Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes, ...

  • Oneida Air Systems 2005c3HP - page 3

    O.A.S. 2005 c 3HP High V acuum Owner s Manual I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician w ...

  • Oneida Air Systems 2005c3HP - page 4

    II. 3hp High Vacuum Configuration O.A.S. 2005 c 3HP High V acuum Owner s Manual 3 Pleated Cartridge Filters (Do not remove fabric straps from cartridge.) Removable Dust Container Removable 55 Gal. Metal Chip / Dust Bin 3hp Integral Fan Blower Angle Iron S t and Flex Hose Outlet Inlet Elbow Square-to-Round Cone Cyclone ...

  • Oneida Air Systems 2005c3HP - page 5

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 4 III. General Specifications & Fan Per formance Cur ves Physical and Electrical Data for 3 hp High V acuum Unit. 3hp - 1342 cfm @ 3.5 SP System Performance Height w/ 55 Gal. Drum: 1 10 1/8 Footprint: 56 x 34 Fan Wheel diameter: 15 Backward Incline design Cyclone Inlet: 6 System Di ...

  • Oneida Air Systems 2005c3HP - page 6

    IV . Dimensions O.A.S. 2005 c 3HP High V acuum Owner s Manual 5 22 6 1/8 4 28 1/2 7 1/4 36 75 3/4 1 1 1 7/8 12 62 30 7/8 10.031 I.D. 7.64 I.D. 1.25 Flange For Minimum Mounting Heights with 55 gal. drum 26 1/8 O.D. of Mounting Ring Bolt Holes 24 7/8 18 56 Outlet Size 56 7 3/4 14 1/8 1 ...

  • Oneida Air Systems 2005c3HP - page 7

    O.A.S. 2005 c 3HP High V acuum Owner s Manual V . Angle Iron Stand Bolt together the stand using the cross bars and 3/8 x 1 bolt s. Note: the cross bar on the cyclone stand goes in the back so that the dust bin can slide out. 55 Gal. 30 7/8 28 7/8 75 7/8 6 ...

  • Oneida Air Systems 2005c3HP - page 8

    O.A.S. 2005 c 3HP High V acuum Owner s Manual Cyclone Barrel Cyclone Cone 2. 3. 2. Clamp the fan housing and cyclone barrel to the cyclone cone with the clamp ring. Note: the fan / blower and the cyclone barrel are very heavy . The system will be top heavy . One method is to lay the stand down, then bolt the cyclone with the fan / blower to the ...

  • Oneida Air Systems 2005c3HP - page 9

    VI. Assembly Instructions (Cont.) O.A.S. 2005 c 3HP High V acuum Owner s Manual 5. Attach flex hose to bottom of collector and to lid of dust bin. Securely fasten hose clamps. There must be an air tight seal between the collector and dust bin. 6. Make sure the dust bin lid sit s securely and the rubber gasket on the bin lid is in place on the ba ...

  • Oneida Air Systems 2005c3HP - page 10

    VIII. Filter Maintenance 3HP High Pressure Owner s Manual O.A.S. 2005 c External Filter Cartridge Cleaning Intervals Caution: Fine dust collected in filter is hazardous to your health! Do not breathe! When unit is turned of f, use compressed air to blow dust off from exterior of filter . Hold nozzle at least 8 away from filter pleats*. Do not ...

  • Oneida Air Systems 2005c3HP - page 11

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 10 IX . Single and Three Phase Wire Diagram Use wiring diagram on motor plate if dif ferent from below . - Electrically insulate all connections. - For counter-clockwise rot ation, looking from top of motor down. 3hp Single Phase Baldor Motor / 230v / 14.5 amp s / TEFC Wiring should always be done by ...

  • Oneida Air Systems 2005c3HP - page 12

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 11 X . Accessories Dust Bin Options - (Must Order Custom Mounting S tand.) 2. Hoppers - Large capacity hoppers from .5 cu. yd. to 3 cu. yd. 3/16 reinforcing angle for added support - 3/16 plate body is 100% continuously MIG welded on inside - 3/8 rear cross brace angle (not 3/16) - three ...

  • Oneida Air Systems 2005c3HP - page 13

    XI. Troubleshooting Motor Overheating The motor  s internal circuit breaker will trip if the motor is overheating. System should be completely bolted and sealed together . Ductwork should be completely installed and sealed with sealant. Air leaks between the collector and dust bin - The lid of the dust bin and the cyclone must be in place and se ...

  • Oneida Air Systems 2005c3HP - page 14

    XII. Fire Hazards - Read Before Installing and Operating Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust collector . Personnel should keep at least 20 feet away f ...

  • Oneida Air Systems 2005c3HP - page 15

    XIII. T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive conceale ...

  • Oneida Air Systems 2005c3HP - page 16

    3HP High Pressure Owner s Manual 15 ...

Manufacturer Oneida Air Systems Category Dust Collector

Documents that we receive from a manufacturer of a Oneida Air Systems 2005c3HP can be divided into several groups. They are, among others:
- Oneida Air Systems technical drawings
- 2005c3HP manuals
- Oneida Air Systems product data sheets
- information booklets
- or energy labels Oneida Air Systems 2005c3HP
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oneida Air Systems 2005c3HP.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oneida Air Systems 2005c3HP, service manual, brief instructions and user manuals Oneida Air Systems 2005c3HP. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oneida Air Systems 2005c3HP.

A complete manual for the device Oneida Air Systems 2005c3HP, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oneida Air Systems 2005c3HP by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oneida Air Systems 2005c3HP.

A complete Oneida Air Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oneida Air Systems 2005c3HP - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oneida Air Systems 2005c3HP, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oneida Air Systems 2005c3HP, that we can find in the current document
3. Tips how to use the basic functions of the device Oneida Air Systems 2005c3HP - which should help us in our first steps of using Oneida Air Systems 2005c3HP
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oneida Air Systems 2005c3HP
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oneida Air Systems 2005c3HP in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oneida Air Systems 2005c3HP?

Use the form below

If you did not solve your problem by using a manual Oneida Air Systems 2005c3HP, ask a question using the form below. If a user had a similar problem with Oneida Air Systems 2005c3HP it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)