  • Oneida Air Systems 2005c3HP - page 1

    3HP High Vacuum Dust Collector Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Owners Man ual ...

  • Oneida Air Systems 2005c3HP - page 2

    Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes, ...

  • Oneida Air Systems 2005c3HP - page 3

    O.A.S. 2005 c 3HP High V acuum Owner s Manual I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician w ...

  • Oneida Air Systems 2005c3HP - page 4

    II. 3hp High Vacuum Configuration O.A.S. 2005 c 3HP High V acuum Owner s Manual 3 Pleated Cartridge Filters (Do not remove fabric straps from cartridge.) Removable Dust Container Removable 55 Gal. Metal Chip / Dust Bin 3hp Integral Fan Blower Angle Iron S t and Flex Hose Outlet Inlet Elbow Square-to-Round Cone Cyclone ...

  • Oneida Air Systems 2005c3HP - page 5

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 4 III. General Specifications & Fan Per formance Cur ves Physical and Electrical Data for 3 hp High V acuum Unit. 3hp - 1342 cfm @ 3.5 SP System Performance Height w/ 55 Gal. Drum: 1 10 1/8 Footprint: 56 x 34 Fan Wheel diameter: 15 Backward Incline design Cyclone Inlet: 6 System Di ...

  • Oneida Air Systems 2005c3HP - page 6

    IV . Dimensions O.A.S. 2005 c 3HP High V acuum Owner s Manual 5 22 6 1/8 4 28 1/2 7 1/4 36 75 3/4 1 1 1 7/8 12 62 30 7/8 10.031 I.D. 7.64 I.D. 1.25 Flange For Minimum Mounting Heights with 55 gal. drum 26 1/8 O.D. of Mounting Ring Bolt Holes 24 7/8 18 56 Outlet Size 56 7 3/4 14 1/8 1 ...

  • Oneida Air Systems 2005c3HP - page 7

    O.A.S. 2005 c 3HP High V acuum Owner s Manual V . Angle Iron Stand Bolt together the stand using the cross bars and 3/8 x 1 bolt s. Note: the cross bar on the cyclone stand goes in the back so that the dust bin can slide out. 55 Gal. 30 7/8 28 7/8 75 7/8 6 ...

  • Oneida Air Systems 2005c3HP - page 8

    O.A.S. 2005 c 3HP High V acuum Owner s Manual Cyclone Barrel Cyclone Cone 2. 3. 2. Clamp the fan housing and cyclone barrel to the cyclone cone with the clamp ring. Note: the fan / blower and the cyclone barrel are very heavy . The system will be top heavy . One method is to lay the stand down, then bolt the cyclone with the fan / blower to the ...

  • Oneida Air Systems 2005c3HP - page 9

    VI. Assembly Instructions (Cont.) O.A.S. 2005 c 3HP High V acuum Owner s Manual 5. Attach flex hose to bottom of collector and to lid of dust bin. Securely fasten hose clamps. There must be an air tight seal between the collector and dust bin. 6. Make sure the dust bin lid sit s securely and the rubber gasket on the bin lid is in place on the ba ...

  • Oneida Air Systems 2005c3HP - page 10

    VIII. Filter Maintenance 3HP High Pressure Owner s Manual O.A.S. 2005 c External Filter Cartridge Cleaning Intervals Caution: Fine dust collected in filter is hazardous to your health! Do not breathe! When unit is turned of f, use compressed air to blow dust off from exterior of filter . Hold nozzle at least 8 away from filter pleats*. Do not ...

  • Oneida Air Systems 2005c3HP - page 11

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 10 IX . Single and Three Phase Wire Diagram Use wiring diagram on motor plate if dif ferent from below . - Electrically insulate all connections. - For counter-clockwise rot ation, looking from top of motor down. 3hp Single Phase Baldor Motor / 230v / 14.5 amp s / TEFC Wiring should always be done by ...

  • Oneida Air Systems 2005c3HP - page 12

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 11 X . Accessories Dust Bin Options - (Must Order Custom Mounting S tand.) 2. Hoppers - Large capacity hoppers from .5 cu. yd. to 3 cu. yd. 3/16 reinforcing angle for added support - 3/16 plate body is 100% continuously MIG welded on inside - 3/8 rear cross brace angle (not 3/16) - three ...

  • Oneida Air Systems 2005c3HP - page 13

    XI. Troubleshooting Motor Overheating The motor  s internal circuit breaker will trip if the motor is overheating. System should be completely bolted and sealed together . Ductwork should be completely installed and sealed with sealant. Air leaks between the collector and dust bin - The lid of the dust bin and the cyclone must be in place and se ...

  • Oneida Air Systems 2005c3HP - page 14

    XII. Fire Hazards - Read Before Installing and Operating Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust collector . Personnel should keep at least 20 feet away f ...

  • Oneida Air Systems 2005c3HP - page 15

    XIII. T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive conceale ...

  • Oneida Air Systems 2005c3HP - page 16

    3HP High Pressure Owner s Manual 15 ...

Fabricante Oneida Air Systems Categoría Dust Collector

Los documentos del dispositivo Oneida Air Systems 2005c3HP que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Oneida Air Systems
- manuales de instrucciones 2005c3HP
- hojas de producto Oneida Air Systems
- folletos informativos
- o etiquetas energéticas Oneida Air Systems 2005c3HP
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Oneida Air Systems 2005c3HP.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Oneida Air Systems 2005c3HP, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Oneida Air Systems 2005c3HP. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Oneida Air Systems 2005c3HP.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Oneida Air Systems 2005c3HP, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Oneida Air Systems 2005c3HP. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Oneida Air Systems 2005c3HP.

El manual de instrucciones completo de Oneida Air Systems debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Oneida Air Systems 2005c3HP - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Oneida Air Systems 2005c3HP, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Oneida Air Systems 2005c3HP que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Oneida Air Systems 2005c3HP - que deben facilitarnos los primeros pasos durante el uso de Oneida Air Systems 2005c3HP
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Oneida Air Systems 2005c3HP
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Oneida Air Systems 2005c3HP en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Oneida Air Systems 2005c3HP?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Oneida Air Systems 2005c3HP, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Oneida Air Systems 2005c3HP probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)