    3HP High Vacuum Dust Collector Oneida Air Systems, Inc. 1001 West Fayette S t., Syracuse, N.Y . 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www .oneida-air .com Owners Man ual ...

  • Oneida Air Systems 2005c3HP - page 2

    Thank Y ou for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only . Our qualified technicians and sales staf f are available 7:30am - 6:00pm EST Mon. - Thur . and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes, ...

  • Oneida Air Systems 2005c3HP - page 3

    O.A.S. 2005 c 3HP High V acuum Owner s Manual I. System Star t-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3. Have licensed electrician w ...

  • Oneida Air Systems 2005c3HP - page 4

    II. 3hp High Vacuum Configuration O.A.S. 2005 c 3HP High V acuum Owner s Manual 3 Pleated Cartridge Filters (Do not remove fabric straps from cartridge.) Removable Dust Container Removable 55 Gal. Metal Chip / Dust Bin 3hp Integral Fan Blower Angle Iron S t and Flex Hose Outlet Inlet Elbow Square-to-Round Cone Cyclone ...

  • Oneida Air Systems 2005c3HP - page 5

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 4 III. General Specifications & Fan Per formance Cur ves Physical and Electrical Data for 3 hp High V acuum Unit. 3hp - 1342 cfm @ 3.5 SP System Performance Height w/ 55 Gal. Drum: 1 10 1/8 Footprint: 56 x 34 Fan Wheel diameter: 15 Backward Incline design Cyclone Inlet: 6 System Di ...

  • Oneida Air Systems 2005c3HP - page 6

    IV . Dimensions O.A.S. 2005 c 3HP High V acuum Owner s Manual 5 22 6 1/8 4 28 1/2 7 1/4 36 75 3/4 1 1 1 7/8 12 62 30 7/8 10.031 I.D. 7.64 I.D. 1.25 Flange For Minimum Mounting Heights with 55 gal. drum 26 1/8 O.D. of Mounting Ring Bolt Holes 24 7/8 18 56 Outlet Size 56 7 3/4 14 1/8 1 ...

  • Oneida Air Systems 2005c3HP - page 7

    O.A.S. 2005 c 3HP High V acuum Owner s Manual V . Angle Iron Stand Bolt together the stand using the cross bars and 3/8 x 1 bolt s. Note: the cross bar on the cyclone stand goes in the back so that the dust bin can slide out. 55 Gal. 30 7/8 28 7/8 75 7/8 6 ...

  • Oneida Air Systems 2005c3HP - page 8

    O.A.S. 2005 c 3HP High V acuum Owner s Manual Cyclone Barrel Cyclone Cone 2. 3. 2. Clamp the fan housing and cyclone barrel to the cyclone cone with the clamp ring. Note: the fan / blower and the cyclone barrel are very heavy . The system will be top heavy . One method is to lay the stand down, then bolt the cyclone with the fan / blower to the ...

  • Oneida Air Systems 2005c3HP - page 9

    VI. Assembly Instructions (Cont.) O.A.S. 2005 c 3HP High V acuum Owner s Manual 5. Attach flex hose to bottom of collector and to lid of dust bin. Securely fasten hose clamps. There must be an air tight seal between the collector and dust bin. 6. Make sure the dust bin lid sit s securely and the rubber gasket on the bin lid is in place on the ba ...

  • Oneida Air Systems 2005c3HP - page 10

    VIII. Filter Maintenance 3HP High Pressure Owner s Manual O.A.S. 2005 c External Filter Cartridge Cleaning Intervals Caution: Fine dust collected in filter is hazardous to your health! Do not breathe! When unit is turned of f, use compressed air to blow dust off from exterior of filter . Hold nozzle at least 8 away from filter pleats*. Do not ...

  • Oneida Air Systems 2005c3HP - page 11

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 10 IX . Single and Three Phase Wire Diagram Use wiring diagram on motor plate if dif ferent from below . - Electrically insulate all connections. - For counter-clockwise rot ation, looking from top of motor down. 3hp Single Phase Baldor Motor / 230v / 14.5 amp s / TEFC Wiring should always be done by ...

  • Oneida Air Systems 2005c3HP - page 12

    O.A.S. 2005 c 3HP High V acuum Owner s Manual 11 X . Accessories Dust Bin Options - (Must Order Custom Mounting S tand.) 2. Hoppers - Large capacity hoppers from .5 cu. yd. to 3 cu. yd. 3/16 reinforcing angle for added support - 3/16 plate body is 100% continuously MIG welded on inside - 3/8 rear cross brace angle (not 3/16) - three ...

  • Oneida Air Systems 2005c3HP - page 13

    XI. Troubleshooting Motor Overheating The motor  s internal circuit breaker will trip if the motor is overheating. System should be completely bolted and sealed together . Ductwork should be completely installed and sealed with sealant. Air leaks between the collector and dust bin - The lid of the dust bin and the cyclone must be in place and se ...

  • Oneida Air Systems 2005c3HP - page 14

    XII. Fire Hazards - Read Before Installing and Operating Do not use this product to collect other types of dust or flammable vapors. Fire or explosion may occur! Never collect sparks from a bench grinder into a wood dust collector . Never introduce sparks or sources of ignition into the dust collector . Personnel should keep at least 20 feet away f ...

  • Oneida Air Systems 2005c3HP - page 15

    XIII. T erms and Conditions Please look over the shipped order very carefully in the presence of the delivery person for damage or incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive conceale ...

  • Oneida Air Systems 2005c3HP - page 16

    3HP High Pressure Owner s Manual 15 ...

Fabbricante Oneida Air Systems Categoria Dust Collector

I documenti che otteniamo dal fabbricante del dispositivoOneida Air Systems 2005c3HP possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Oneida Air Systems
- manuali per l’uso 2005c3HP
- schede prodotto Oneida Air Systems
- opuscoli
- o etichette energetiche Oneida Air Systems 2005c3HP
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Oneida Air Systems 2005c3HP.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Oneida Air Systems 2005c3HP, manuali di manutenzione, brevi manuali o manuali utente Oneida Air Systems 2005c3HP. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Oneida Air Systems 2005c3HP.

Manuale completo del dispositivo Oneida Air Systems 2005c3HP, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Oneida Air Systems 2005c3HP dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Oneida Air Systems 2005c3HP.

Il manuale per l’uso completo Oneida Air Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Oneida Air Systems 2005c3HP - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Oneida Air Systems 2005c3HP, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Oneida Air Systems 2005c3HP che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Oneida Air Systems 2005c3HP - che ci dovrebbe aiutare nei primi passi durante l'uso Oneida Air Systems 2005c3HP
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Oneida Air Systems 2005c3HP
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Oneida Air Systems 2005c3HP in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Oneida Air Systems 2005c3HP?

Utilizza il modulo sottostante

Se non hai risolto il problema con Oneida Air Systems 2005c3HP con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Oneida Air Systems 2005c3HP è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)