    V enezia Z VE-E3 0S Z VE-E3 6S Z VE-E42S Model number: Serial number: Use, Care, and Installation Guide MAY07.0101 © Zeph yr Corporation. www .zephyronline.com ...

  • Zephyr ZVE-E36S - page 2

    www .zephyronline.com ...

  • Zephyr ZVE-E36S - page 3

    T able of Contents 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specific ...

  • Zephyr ZVE-E36S - page 4

    www .zephyronline.com Im p or tan t s afet y N ot i c e 2 T O RE DUC E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T US E T H IS FAN W ITH ANY S O L ID- S T ATE SP E E D C O NTRO L D EV I C E. TO R E DUC E T H E R I S K O F F I R E, E L E C T R I C S H O C K, O R INJ U R Y TO P E R SON S, O B S E RVE T H E F O L LO W I N G: a. Use ...

  • Zephyr ZVE-E36S - page 5

    List of Materials 3 1 - Hood 2 - Metallic lters (3 - ZVE-E3 6, E42) 2 - Halogen light bulbs (4 - ZVE-E3 6, E42) 1 - Duct cover assembly (2 pieces) 1 - Hardware bag 1 - Duct cover mounting bracket 1 - Pac ket of mounting screws w/anchors 1 - Buttery damper NO DUC T I NG IS INCLUDED * Note: Zephyr recommends using 5 0LB E Z anchors if mounting ...

  • Zephyr ZVE-E36S - page 6

    www .zephyronline.com 4 Installation - Ductwork Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 elbow 15 Ft . x ( ) = Ft. 3 1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 ? ...

  • Zephyr ZVE-E36S - page 7

    5 - n o i t a l l a t s n I e c n a r a e l C & t h g i e H g n i t n u o M DUC T ING min. ducted - 32 1/2” min recirc. - 36” max. 51” *m i n . 9 7 " * * ma x. 123" 36" 9 -27/32" mi n . 2 8" - max . 3 6" Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount hei ...

  • Zephyr ZVE-E36S - page 8

    www .zephyronline.com 6 Installation - Ducting W AR NING F IRE HA ZA RD N EVE R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . Fasten all connections with sheet metal s ...

  • Zephyr ZVE-E36S - page 9

    7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 6.5" 6" 10.37" 13.87" 2.78" 1.87" 0.5" 3/4" Elec. K.O. Cable Lock All Electrical work must by performed by qualied electrician or person with similar technical know how and backgr ound. F or personal safety , remove house fuse or open circuit breaker ...

  • Zephyr ZVE-E36S - page 10

    www .zephyronline.com 8 - n o i t a l l a t s n I r e v o C t c u D & d o o H e h t g n i t n u o M 1. Measure from range top to hood bottom (28” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (10-3/8” from line A) 4. Mark mounting spread from C/ L (9-7 /16”) 5. Fasten E-Z anc hors to wall (see b ...

  • Zephyr ZVE-E36S - page 11

    9 Installation - Ductless Recirculating Ductless recirculating i s intended for applications where an exhaust duct work is not possible to be installed. W hen converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and e xhaust from cooking is drawn and ltered by a set of optional charcoal lters. The a ...

  • Zephyr ZVE-E36S - page 12

    www .zephyronline.com 10 F eatures & Controls - T ouc h Controls & F eatures The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blo wer eciency . If improperly maintained, residue from cooking will sift though lters and cause damage to hood blowers and other sensitive components; a ...

  • Zephyr ZVE-E36S - page 13

    11 F eatures & Controls - Charcoal Filters Change Indicator Filter Change Reminder (Charcoal, if tted): W hen your hood is installed as a ' Recirculating' (Ductless) unit, it is tted with a set of Charcoal Filters to purify e xhaust and fumes from cooking, then re-circulate the air within the home.These Charcoal Filters are requ ...

  • Zephyr ZVE-E36S - page 14

    www .zephyronline.com 12 F eatures & Controls - Metal Filters Clean Indicator Filter Clean Reminder (Standard Metal Filters tted): W hether your hood is installed as an Exhaust or Purifying unit, a set of metal lters are tted by the factory . These Metal Filters are intended to lter out residue from cooking. They need not be replace ...

  • Zephyr ZVE-E36S - page 15

    13 Maintenance - Cleaning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratc h and damage surface. F or heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish a ...

  • Zephyr ZVE-E36S - page 16

    www .zephyronline.com 14 Maintenance - Lights Replacing Light Bulbs CA UTI O N: Light bulb becomes extremely hot when turned on. DO NO T touch bulb until switched o and cooled. T ouc hing hot bulbs could cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove by turning bulb counter clockwise. If bulbs are dicult ...

  • Zephyr ZVE-E36S - page 17

    15 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal lter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable loc king connector is not connecting pr ...

  • Zephyr ZVE-E36S - page 18

    List of Parts and A ccessories 16 Light Bulb (J D R-E27) Z0B-0011 Metallic Filters (2 pk) Z0F-M042 Metallic Filters (3 pk) Z0F-M043 T elescopic Back Splash 30” Z0S-0013 T elescopic Back Splash 36” Z0S-0016 T elescopic Back Splash 42” Z0S-0012 W ire Spice Rack 30” Z0R-0013 W ire Spice Rack 36” Z0R-0016 W ire Spice Rack 42” Z0R-0012 T o o ...

  • Zephyr ZVE-E36S - page 19

    www.zephyronline.com Warranty One Y ear Service R epair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects. O n e Y ear Parts W arranty: F or one year from date of original purchase, we will provide free of charge, nonconsumabl ...

Fabricant Zephyr Catégorie Ventilation Hood

Les documents que nous recevons du fabricant de l'appareilZephyr ZVE-E36S peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Zephyr
- manuels d’utilisations ZVE-E36S
- fiches produit Zephyr
- dépliants
- ou étiquettes-énergie Zephyr ZVE-E36S
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Zephyr ZVE-E36S.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Zephyr ZVE-E36S, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Zephyr ZVE-E36S. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Zephyr ZVE-E36S.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Zephyr ZVE-E36S, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Zephyr ZVE-E36S par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Zephyr ZVE-E36S.

Le manuel d’utilisation complet Zephyr, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Zephyr ZVE-E36S - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Zephyr ZVE-E36S, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lZephyr ZVE-E36S qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Zephyr ZVE-E36S - qui devraient nous aider dans les premières étapes lors de l'utilisation Zephyr ZVE-E36S
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Zephyr ZVE-E36S
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Zephyr ZVE-E36S dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Zephyr ZVE-E36S?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Zephyr ZVE-E36S, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Zephyr ZVE-E36S il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)