Manuale per l’uso Zephyr ZVE-E36S

19 pagine 0.68 mb
Scarica

Vai alla pagina of 19

Summary
  • Zephyr ZVE-E36S - page 1

    V enezia Z VE-E3 0S Z VE-E3 6S Z VE-E42S Model number: Serial number: Use, Care, and Installation Guide MAY07.0101 © Zeph yr Corporation. www .zephyronline.com ...

  • Zephyr ZVE-E36S - page 2

    www .zephyronline.com ...

  • Zephyr ZVE-E36S - page 3

    T able of Contents 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specific ...

  • Zephyr ZVE-E36S - page 4

    www .zephyronline.com Im p or tan t s afet y N ot i c e 2 T O RE DUC E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T US E T H IS FAN W ITH ANY S O L ID- S T ATE SP E E D C O NTRO L D EV I C E. TO R E DUC E T H E R I S K O F F I R E, E L E C T R I C S H O C K, O R INJ U R Y TO P E R SON S, O B S E RVE T H E F O L LO W I N G: a. Use ...

  • Zephyr ZVE-E36S - page 5

    List of Materials 3 1 - Hood 2 - Metallic lters (3 - ZVE-E3 6, E42) 2 - Halogen light bulbs (4 - ZVE-E3 6, E42) 1 - Duct cover assembly (2 pieces) 1 - Hardware bag 1 - Duct cover mounting bracket 1 - Pac ket of mounting screws w/anchors 1 - Buttery damper NO DUC T I NG IS INCLUDED * Note: Zephyr recommends using 5 0LB E Z anchors if mounting ...

  • Zephyr ZVE-E36S - page 6

    www .zephyronline.com 4 Installation - Ductwork Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 elbow 15 Ft . x ( ) = Ft. 3 1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 ? ...

  • Zephyr ZVE-E36S - page 7

    5 - n o i t a l l a t s n I e c n a r a e l C & t h g i e H g n i t n u o M DUC T ING min. ducted - 32 1/2” min recirc. - 36” max. 51” *m i n . 9 7 " * * ma x. 123" 36" 9 -27/32" mi n . 2 8" - max . 3 6" Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount hei ...

  • Zephyr ZVE-E36S - page 8

    www .zephyronline.com 6 Installation - Ducting W AR NING F IRE HA ZA RD N EVE R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . Fasten all connections with sheet metal s ...

  • Zephyr ZVE-E36S - page 9

    7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 6.5" 6" 10.37" 13.87" 2.78" 1.87" 0.5" 3/4" Elec. K.O. Cable Lock All Electrical work must by performed by qualied electrician or person with similar technical know how and backgr ound. F or personal safety , remove house fuse or open circuit breaker ...

  • Zephyr ZVE-E36S - page 10

    www .zephyronline.com 8 - n o i t a l l a t s n I r e v o C t c u D & d o o H e h t g n i t n u o M 1. Measure from range top to hood bottom (28” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (10-3/8” from line A) 4. Mark mounting spread from C/ L (9-7 /16”) 5. Fasten E-Z anc hors to wall (see b ...

  • Zephyr ZVE-E36S - page 11

    9 Installation - Ductless Recirculating Ductless recirculating i s intended for applications where an exhaust duct work is not possible to be installed. W hen converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and e xhaust from cooking is drawn and ltered by a set of optional charcoal lters. The a ...

  • Zephyr ZVE-E36S - page 12

    www .zephyronline.com 10 F eatures & Controls - T ouc h Controls & F eatures The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blo wer eciency . If improperly maintained, residue from cooking will sift though lters and cause damage to hood blowers and other sensitive components; a ...

  • Zephyr ZVE-E36S - page 13

    11 F eatures & Controls - Charcoal Filters Change Indicator Filter Change Reminder (Charcoal, if tted): W hen your hood is installed as a ' Recirculating' (Ductless) unit, it is tted with a set of Charcoal Filters to purify e xhaust and fumes from cooking, then re-circulate the air within the home.These Charcoal Filters are requ ...

  • Zephyr ZVE-E36S - page 14

    www .zephyronline.com 12 F eatures & Controls - Metal Filters Clean Indicator Filter Clean Reminder (Standard Metal Filters tted): W hether your hood is installed as an Exhaust or Purifying unit, a set of metal lters are tted by the factory . These Metal Filters are intended to lter out residue from cooking. They need not be replace ...

  • Zephyr ZVE-E36S - page 15

    13 Maintenance - Cleaning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratc h and damage surface. F or heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish a ...

  • Zephyr ZVE-E36S - page 16

    www .zephyronline.com 14 Maintenance - Lights Replacing Light Bulbs CA UTI O N: Light bulb becomes extremely hot when turned on. DO NO T touch bulb until switched o and cooled. T ouc hing hot bulbs could cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove by turning bulb counter clockwise. If bulbs are dicult ...

  • Zephyr ZVE-E36S - page 17

    15 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal lter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable loc king connector is not connecting pr ...

  • Zephyr ZVE-E36S - page 18

    List of Parts and A ccessories 16 Light Bulb (J D R-E27) Z0B-0011 Metallic Filters (2 pk) Z0F-M042 Metallic Filters (3 pk) Z0F-M043 T elescopic Back Splash 30” Z0S-0013 T elescopic Back Splash 36” Z0S-0016 T elescopic Back Splash 42” Z0S-0012 W ire Spice Rack 30” Z0R-0013 W ire Spice Rack 36” Z0R-0016 W ire Spice Rack 42” Z0R-0012 T o o ...

  • Zephyr ZVE-E36S - page 19

    www.zephyronline.com Warranty One Y ear Service R epair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects. O n e Y ear Parts W arranty: F or one year from date of original purchase, we will provide free of charge, nonconsumabl ...

Fabbricante Zephyr Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoZephyr ZVE-E36S possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Zephyr
- manuali per l’uso ZVE-E36S
- schede prodotto Zephyr
- opuscoli
- o etichette energetiche Zephyr ZVE-E36S
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Zephyr ZVE-E36S.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Zephyr ZVE-E36S, manuali di manutenzione, brevi manuali o manuali utente Zephyr ZVE-E36S. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Zephyr ZVE-E36S.

Manuali per l’uso simili

Manuale completo del dispositivo Zephyr ZVE-E36S, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Zephyr ZVE-E36S dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Zephyr ZVE-E36S.

Il manuale per l’uso completo Zephyr, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Zephyr ZVE-E36S - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Zephyr ZVE-E36S, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Zephyr ZVE-E36S che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Zephyr ZVE-E36S - che ci dovrebbe aiutare nei primi passi durante l'uso Zephyr ZVE-E36S
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Zephyr ZVE-E36S
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Zephyr ZVE-E36S in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Zephyr ZVE-E36S?

Utilizza il modulo sottostante

Se non hai risolto il problema con Zephyr ZVE-E36S con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Zephyr ZVE-E36S è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine