    V enezia Z VE-E3 0S Z VE-E3 6S Z VE-E42S Model number: Serial number: Use, Care, and Installation Guide MAY07.0101 © Zeph yr Corporation. www .zephyronline.com ...

  • Zephyr ZVE-E36S - page 2

    www .zephyronline.com ...

  • Zephyr ZVE-E36S - page 3

    T able of Contents 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specific ...

  • Zephyr ZVE-E36S - page 4

    www .zephyronline.com Im p or tan t s afet y N ot i c e 2 T O RE DUC E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T US E T H IS FAN W ITH ANY S O L ID- S T ATE SP E E D C O NTRO L D EV I C E. TO R E DUC E T H E R I S K O F F I R E, E L E C T R I C S H O C K, O R INJ U R Y TO P E R SON S, O B S E RVE T H E F O L LO W I N G: a. Use ...

  • Zephyr ZVE-E36S - page 5

    List of Materials 3 1 - Hood 2 - Metallic lters (3 - ZVE-E3 6, E42) 2 - Halogen light bulbs (4 - ZVE-E3 6, E42) 1 - Duct cover assembly (2 pieces) 1 - Hardware bag 1 - Duct cover mounting bracket 1 - Pac ket of mounting screws w/anchors 1 - Buttery damper NO DUC T I NG IS INCLUDED * Note: Zephyr recommends using 5 0LB E Z anchors if mounting ...

  • Zephyr ZVE-E36S - page 6

    www .zephyronline.com 4 Installation - Ductwork Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 elbow 15 Ft . x ( ) = Ft. 3 1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 ? ...

  • Zephyr ZVE-E36S - page 7

    5 - n o i t a l l a t s n I e c n a r a e l C & t h g i e H g n i t n u o M DUC T ING min. ducted - 32 1/2” min recirc. - 36” max. 51” *m i n . 9 7 " * * ma x. 123" 36" 9 -27/32" mi n . 2 8" - max . 3 6" Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount hei ...

  • Zephyr ZVE-E36S - page 8

    www .zephyronline.com 6 Installation - Ducting W AR NING F IRE HA ZA RD N EVE R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . Fasten all connections with sheet metal s ...

  • Zephyr ZVE-E36S - page 9

    7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 6.5" 6" 10.37" 13.87" 2.78" 1.87" 0.5" 3/4" Elec. K.O. Cable Lock All Electrical work must by performed by qualied electrician or person with similar technical know how and backgr ound. F or personal safety , remove house fuse or open circuit breaker ...

  • Zephyr ZVE-E36S - page 10

    www .zephyronline.com 8 - n o i t a l l a t s n I r e v o C t c u D & d o o H e h t g n i t n u o M 1. Measure from range top to hood bottom (28” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (10-3/8” from line A) 4. Mark mounting spread from C/ L (9-7 /16”) 5. Fasten E-Z anc hors to wall (see b ...

  • Zephyr ZVE-E36S - page 11

    9 Installation - Ductless Recirculating Ductless recirculating i s intended for applications where an exhaust duct work is not possible to be installed. W hen converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and e xhaust from cooking is drawn and ltered by a set of optional charcoal lters. The a ...

  • Zephyr ZVE-E36S - page 12

    www .zephyronline.com 10 F eatures & Controls - T ouc h Controls & F eatures The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blo wer eciency . If improperly maintained, residue from cooking will sift though lters and cause damage to hood blowers and other sensitive components; a ...

  • Zephyr ZVE-E36S - page 13

    11 F eatures & Controls - Charcoal Filters Change Indicator Filter Change Reminder (Charcoal, if tted): W hen your hood is installed as a ' Recirculating' (Ductless) unit, it is tted with a set of Charcoal Filters to purify e xhaust and fumes from cooking, then re-circulate the air within the home.These Charcoal Filters are requ ...

  • Zephyr ZVE-E36S - page 14

    www .zephyronline.com 12 F eatures & Controls - Metal Filters Clean Indicator Filter Clean Reminder (Standard Metal Filters tted): W hether your hood is installed as an Exhaust or Purifying unit, a set of metal lters are tted by the factory . These Metal Filters are intended to lter out residue from cooking. They need not be replace ...

  • Zephyr ZVE-E36S - page 15

    13 Maintenance - Cleaning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratc h and damage surface. F or heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish a ...

  • Zephyr ZVE-E36S - page 16

    www .zephyronline.com 14 Maintenance - Lights Replacing Light Bulbs CA UTI O N: Light bulb becomes extremely hot when turned on. DO NO T touch bulb until switched o and cooled. T ouc hing hot bulbs could cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove by turning bulb counter clockwise. If bulbs are dicult ...

  • Zephyr ZVE-E36S - page 17

    15 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal lter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable loc king connector is not connecting pr ...

  • Zephyr ZVE-E36S - page 18

    List of Parts and A ccessories 16 Light Bulb (J D R-E27) Z0B-0011 Metallic Filters (2 pk) Z0F-M042 Metallic Filters (3 pk) Z0F-M043 T elescopic Back Splash 30” Z0S-0013 T elescopic Back Splash 36” Z0S-0016 T elescopic Back Splash 42” Z0S-0012 W ire Spice Rack 30” Z0R-0013 W ire Spice Rack 36” Z0R-0016 W ire Spice Rack 42” Z0R-0012 T o o ...

  • Zephyr ZVE-E36S - page 19

    www.zephyronline.com Warranty One Y ear Service R epair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects. O n e Y ear Parts W arranty: F or one year from date of original purchase, we will provide free of charge, nonconsumabl ...

Manufacturer Zephyr Category Ventilation Hood

Documents that we receive from a manufacturer of a Zephyr ZVE-E36S can be divided into several groups. They are, among others:
- Zephyr technical drawings
- ZVE-E36S manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr ZVE-E36S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr ZVE-E36S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr ZVE-E36S, service manual, brief instructions and user manuals Zephyr ZVE-E36S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr ZVE-E36S.

Similar manuals

A complete manual for the device Zephyr ZVE-E36S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr ZVE-E36S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr ZVE-E36S.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr ZVE-E36S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr ZVE-E36S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr ZVE-E36S, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr ZVE-E36S - which should help us in our first steps of using Zephyr ZVE-E36S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr ZVE-E36S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr ZVE-E36S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr ZVE-E36S?

Use the form below

If you did not solve your problem by using a manual Zephyr ZVE-E36S, ask a question using the form below. If a user had a similar problem with Zephyr ZVE-E36S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)