  • Field Controls SWG Stainless - page 1

    SIDE WALL POWER VENTER KIT Model : SWG, SWGII & SWG Stainless Series * Patented TYPICAL VENTING SYST EM COMPONENTS 1 - SWG Series Power Venter 1 - CK Series Control Kit (sold separately) OPTIONAL SYSTEM COMP ONENTS SWG S ERIES T HROUGH - W ALL E XTENSION K IT F or installation in wall thickness over 8 inches. Models PEK - 4 through PEK - 8 are ...

  • Field Controls SWG Stainless - page 2

    Page 2 CONTROL KITS CK - 20F/HWK: For operation with 30 or 750 millivolt gas - fired water heaters, gas - fired space heaters and gas - fired pool or spa heaters with an internally mount ed thermostat. Includes a fixed post purge. CK - 21: For operation with gas - fired instantaneous water heaters with a pressure tap port in the burner manifold. CK ...

  • Field Controls SWG Stainless - page 3

    Page 3 INSTALLATION OF SWG POWER VENTER ( See Table 1) Table 1 UNIT SIZING CHART OIL GAS MAXIMUM EQUIVALENT FEET OF VENT PIPE MAX* OIL GPH INPUT MAX** BTU/HR. IMPUT AT MAX BTU/HR INPUT AT 60% OF MAX BTU /HR INPUT VENTING WITH VENT PIPE SIZE MODEL 21 80 3” 50 100 4” N/A 70,000 --- --- --- SWG - 3 --- 23 3” 35 100 4” 1.10 170,000 65 100 5” ...

  • Field Controls SWG Stainless - page 4

    Page 4 P ROCEDURE F OR C ALCULATING T OTAL E QUIVALENT P IPE L ENGTH I N F EET 1. Calculate the total equivalent feet for each type of fitting used in the venting system from the chart below. 2. Calculate the total amount of feet for the st raight lengths of vent pipe. 3. Add the equivalent feet for the fitting with the total amount of feet of stra ...

  • Field Controls SWG Stainless - page 5

    Page 5 Figure 2 Figure 3 Figure 4 3. After determining the location of the venting system termination point (see Diagram A), cut a square hole through the wall 1 " larger than the outer pipe diameter of the power venter. Mount the power venter through the wall, keeping the outer pipe centered in the hole. (See Figure 3) Fasten the power venter ...

  • Field Controls SWG Stainless - page 6

    Page 6 Figure 5 C ONNECTING P OWER V ENTER T O A PPLIANCE Venting system should be installed and supported in accordance with the National Flue Gas Code A.N.S.I.Z223.1, or in accordance with any local codes. A vent pipe connector shall be supported for the design and weight of the material employed, to maintain clearances, prevent physical damage a ...

  • Field Controls SWG Stainless - page 7

    Page 7 Figure 6 Figure 7 Figure 8 CLASS B AND CLASS L DOUBLE WALL VENT PIP E INSTALLATION (Follow vent pipe manufacturer's listed or recommended cleara nces from combustible material) 1. Using a hand crimper or a like device, crimp the inner pipe of the S WG power venter approximately 1" long. (See Figure 7) 2. Attach the vent pipe over t ...

  • Field Controls SWG Stainless - page 8

    Page 8 GENERAL INSTALLATION INSPECTION Recommended procedures for safety inspection of an appliance in accordance with the National Fuel Gas Code A.N.S.I.Z223.1. The following procedure will help evaluate the venting system. It is intended as a guide to aid in determining that the venting system is properly installed and is in a safe condition for ...

  • Field Controls SWG Stainless - page 9

    Page 9 Figure 9 Figure 10 REPLACEMENT PARTS Should the motor or blower wheel need replacing, the following replacement items are available. The Repair Motor Assembly contains the Motor and Blower Wheel factory assemble to a mounting bracket. PART NUMBERS MODEL REPAIR MOTOR ASSEMBL Y BLOWER WHEEL SWG - 3 46196601 46131800 SWG/SWGII - 4HD SWG - 4s 46 ...

  • Field Controls SWG Stainless - page 10

    Page 10 Figure 11 Figure 12 Figure 13 Figure 14 I NSTALLATION 1. Insert the blower wheel through the hole in the front plate of the power venter housing. (See Figure 11) 2. Using two nails or awls, align the two center holes of the motor mount bracket and cover plate. Locate the motor assembly into position by sliding the assembly over the mounting ...

  • Field Controls SWG Stainless - page 11

    Page 11 INITIAL BURNER AND V ENTING SYSTEM OP ERATIONAL INFORMATIO N List the following for each operating appliance on the sidewall venting system, as a guide for tune - up or service information annually. DATE: FOR GAS FIRED EQUIPMENT Heating Appliance BTU/HR Input Gas Valve Operation Pressure Vent System Draft Above Draft Hood or Before Barometr ...

  • Field Controls SWG Stainless - page 12

    Page 12 P/N 46139100 Rev J 05/01 ...

Fabricant Field Controls Catégorie Ventilation Hood

Les documents que nous recevons du fabricant de l'appareilField Controls SWG Stainless peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Field Controls
- manuels d’utilisations SWG Stainless
- fiches produit Field Controls
- dépliants
- ou étiquettes-énergie Field Controls SWG Stainless
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Field Controls SWG Stainless.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Field Controls SWG Stainless, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Field Controls SWG Stainless. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Field Controls SWG Stainless.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Field Controls SWG Stainless, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Field Controls SWG Stainless par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Field Controls SWG Stainless.

Le manuel d’utilisation complet Field Controls, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Field Controls SWG Stainless - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Field Controls SWG Stainless, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lField Controls SWG Stainless qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Field Controls SWG Stainless - qui devraient nous aider dans les premières étapes lors de l'utilisation Field Controls SWG Stainless
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Field Controls SWG Stainless
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Field Controls SWG Stainless dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Field Controls SWG Stainless?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Field Controls SWG Stainless, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Field Controls SWG Stainless il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)