    Page 1 12821-2-0903 VENTED ROOM HEA TER MODELS RH-25-6 RH-35-6 EFFECTIVE DA TE SEPTEMBER 2003 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL WARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. — Do not stor e or use gasoline or other flam ...

  • Empire Products RH-25-6 - page 2

    Page 2 12821-2-0903 SECTION PAGE Important Safety Information ................................................................................................... .................. 3 Safety Information for Users of LP Gas ......................................................................................... ............ 4 Introduction .......... ...

  • Empire Products RH-25-6 - page 3

    Page 3 12821-2-0903 • Due to high temperatures, the room heater should be located out of traffic and away from furniture and drap- eries. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in ...

  • Empire Products RH-25-6 - page 4

    Page 4 12821-2-0903 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area ma ...

  • Empire Products RH-25-6 - page 5

    Page 5 12821-2-0903 INTRODUCTION Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installa- tion of a vented room heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty ...

  • Empire Products RH-25-6 - page 6

    Page 6 12821-2-0903 Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 1/2" 3/8" 1/2" 3/8" 1.3 cm 1.0 cm 1.3 cm 1.0 cm 10-40 1/2" 1/2" 5/8" 1/2" 1.3 cm 1.3 cm 1.6 cm 1.3 cm 40-100 1/2" 1/2" 3/4" 1/2" 1. ...

  • Empire Products RH-25-6 - page 7

    Page 7 12821-2-0903 CLEARANCES Clearances: When facing the front of the room heater the mini- mum clearances to combustible construction (material) are the following: Right side 6 inches (152mm). Left side 6 inches (152mm). Recommend 18 inches (457mm) on left side for servicing. Do not install in alcove or closet. No horizontal projection above hea ...

  • Empire Products RH-25-6 - page 8

    Page 8 12821-2-0903 VENT SAFETY SHUTOFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. Warning: Operation of this heater, when not connected to a prop- erly installed and maintained venting system or tamper- ing with the vent safety shutoff system, can result in carbon m ...

  • Empire Products RH-25-6 - page 9

    Page 9 12821-2-0903 1. STOP! Read the safety information to the left of this label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 6. Wait ten (10) minutes to clear out any ...

  • Empire Products RH-25-6 - page 10

    Page 10 12821-2-0903 PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting whe ...

  • Empire Products RH-25-6 - page 11

    Page 11 12821-2-0903 To Remove Main Burner 1. Disconnect the thermocouple and pilot supply line at the pilot burner. 2. Unscrew the nut on the orifice fitting union. Orifice fitting is threaded into the main burner. 3. Remove screw on each side of the main burner and lift out. To Remove Main Burner Orifice 1. Unscrew the nut on the orifice fitting ...

  • Empire Products RH-25-6 - page 12

    Page 12 12821-2-0903 INDEX PART NO. NUMBER DESCRIPTION INDEX PART NO. NUMBER DESCRIPTION 1 R-6096 Knob & Adaptor Set 2 11700 Control Rod Bracket 3 R-2706 ECO Switch 4 R-926 Cable Assembly 5 11699 Control Rod 6 R-6104 Gas Valve (LPG) 6 R-6103 Gas Valve (Nat) 7 11697 Valve Bracket 8 RH-705 Casing Side 9 RH-708 Air Inlet Baffle 10 P-86-37 Main Bur ...

  • Empire Products RH-25-6 - page 13

    Page 13 12821-2-0903 P AR TS VIEW ...

  • Empire Products RH-25-6 - page 14

    Page 14 12821-2-0903 DRB-1 For V ented Room Heaters Models RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Dir ect V ent W all Furnaces DV -25-(1, 2)SG and DV -35-(1, 2)SG Installing Optional DRB-1 Blower 1. For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) , remove casing front. 1. For DV-25-(1, 2)SG and DV-35-(1, 2)SG , remove casing front and ...

  • Empire Products RH-25-6 - page 15

    Page 15 12821-2-0903 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1 , if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] pl ...

  • Empire Products RH-25-6 - page 16

    Page 16 12821-2-0903 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen F reeburg A ve. Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: info@empirecomf or t.com WEB SITE: www .empirecomf or t.com ...

Fabricant Empire Products Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilEmpire Products RH-25-6 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Empire Products
- manuels d’utilisations RH-25-6
- fiches produit Empire Products
- dépliants
- ou étiquettes-énergie Empire Products RH-25-6
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Empire Products RH-25-6.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Empire Products RH-25-6, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Empire Products RH-25-6. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Empire Products RH-25-6.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Empire Products RH-25-6, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Empire Products RH-25-6 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Empire Products RH-25-6.

Le manuel d’utilisation complet Empire Products, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Empire Products RH-25-6 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Empire Products RH-25-6, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEmpire Products RH-25-6 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Empire Products RH-25-6 - qui devraient nous aider dans les premières étapes lors de l'utilisation Empire Products RH-25-6
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Empire Products RH-25-6
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Empire Products RH-25-6 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Empire Products RH-25-6?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Empire Products RH-25-6, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Empire Products RH-25-6 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image