  • Empire Products RH-25-6 - page 1

    Page 1 12821-2-0903 VENTED ROOM HEA TER MODELS RH-25-6 RH-35-6 EFFECTIVE DA TE SEPTEMBER 2003 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL WARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. — Do not stor e or use gasoline or other flam ...

  • Empire Products RH-25-6 - page 2

    Page 2 12821-2-0903 SECTION PAGE Important Safety Information ................................................................................................... .................. 3 Safety Information for Users of LP Gas ......................................................................................... ............ 4 Introduction .......... ...

  • Empire Products RH-25-6 - page 3

    Page 3 12821-2-0903 • Due to high temperatures, the room heater should be located out of traffic and away from furniture and drap- eries. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in ...

  • Empire Products RH-25-6 - page 4

    Page 4 12821-2-0903 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area ma ...

  • Empire Products RH-25-6 - page 5

    Page 5 12821-2-0903 INTRODUCTION Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installa- tion of a vented room heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty ...

  • Empire Products RH-25-6 - page 6

    Page 6 12821-2-0903 Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 1/2" 3/8" 1/2" 3/8" 1.3 cm 1.0 cm 1.3 cm 1.0 cm 10-40 1/2" 1/2" 5/8" 1/2" 1.3 cm 1.3 cm 1.6 cm 1.3 cm 40-100 1/2" 1/2" 3/4" 1/2" 1. ...

  • Empire Products RH-25-6 - page 7

    Page 7 12821-2-0903 CLEARANCES Clearances: When facing the front of the room heater the mini- mum clearances to combustible construction (material) are the following: Right side 6 inches (152mm). Left side 6 inches (152mm). Recommend 18 inches (457mm) on left side for servicing. Do not install in alcove or closet. No horizontal projection above hea ...

  • Empire Products RH-25-6 - page 8

    Page 8 12821-2-0903 VENT SAFETY SHUTOFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. Warning: Operation of this heater, when not connected to a prop- erly installed and maintained venting system or tamper- ing with the vent safety shutoff system, can result in carbon m ...

  • Empire Products RH-25-6 - page 9

    Page 9 12821-2-0903 1. STOP! Read the safety information to the left of this label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 6. Wait ten (10) minutes to clear out any ...

  • Empire Products RH-25-6 - page 10

    Page 10 12821-2-0903 PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting whe ...

  • Empire Products RH-25-6 - page 11

    Page 11 12821-2-0903 To Remove Main Burner 1. Disconnect the thermocouple and pilot supply line at the pilot burner. 2. Unscrew the nut on the orifice fitting union. Orifice fitting is threaded into the main burner. 3. Remove screw on each side of the main burner and lift out. To Remove Main Burner Orifice 1. Unscrew the nut on the orifice fitting ...

  • Empire Products RH-25-6 - page 12

    Page 12 12821-2-0903 INDEX PART NO. NUMBER DESCRIPTION INDEX PART NO. NUMBER DESCRIPTION 1 R-6096 Knob & Adaptor Set 2 11700 Control Rod Bracket 3 R-2706 ECO Switch 4 R-926 Cable Assembly 5 11699 Control Rod 6 R-6104 Gas Valve (LPG) 6 R-6103 Gas Valve (Nat) 7 11697 Valve Bracket 8 RH-705 Casing Side 9 RH-708 Air Inlet Baffle 10 P-86-37 Main Bur ...

  • Empire Products RH-25-6 - page 13

    Page 13 12821-2-0903 P AR TS VIEW ...

  • Empire Products RH-25-6 - page 14

    Page 14 12821-2-0903 DRB-1 For V ented Room Heaters Models RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Dir ect V ent W all Furnaces DV -25-(1, 2)SG and DV -35-(1, 2)SG Installing Optional DRB-1 Blower 1. For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) , remove casing front. 1. For DV-25-(1, 2)SG and DV-35-(1, 2)SG , remove casing front and ...

  • Empire Products RH-25-6 - page 15

    Page 15 12821-2-0903 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1 , if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] pl ...

  • Empire Products RH-25-6 - page 16

    Page 16 12821-2-0903 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen F reeburg A ve. Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: info@empirecomf or t.com WEB SITE: www .empirecomf or t.com ...

Fabbricante Empire Products Categoria Electric Heater

I documenti che otteniamo dal fabbricante del dispositivoEmpire Products RH-25-6 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Empire Products
- manuali per l’uso RH-25-6
- schede prodotto Empire Products
- opuscoli
- o etichette energetiche Empire Products RH-25-6
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Empire Products RH-25-6.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Empire Products RH-25-6, manuali di manutenzione, brevi manuali o manuali utente Empire Products RH-25-6. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Empire Products RH-25-6.

Manuali per l’uso simili

Manuale completo del dispositivo Empire Products RH-25-6, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Empire Products RH-25-6 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Empire Products RH-25-6.

Il manuale per l’uso completo Empire Products, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Empire Products RH-25-6 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Empire Products RH-25-6, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Empire Products RH-25-6 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Empire Products RH-25-6 - che ci dovrebbe aiutare nei primi passi durante l'uso Empire Products RH-25-6
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Empire Products RH-25-6
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Empire Products RH-25-6 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Empire Products RH-25-6?

Utilizza il modulo sottostante

Se non hai risolto il problema con Empire Products RH-25-6 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Empire Products RH-25-6 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)