    Page 1 12821-2-0903 VENTED ROOM HEA TER MODELS RH-25-6 RH-35-6 EFFECTIVE DA TE SEPTEMBER 2003 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL WARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. — Do not stor e or use gasoline or other flam ...

  • Empire Products RH-25-6 - page 2

    Page 2 12821-2-0903 SECTION PAGE Important Safety Information ................................................................................................... .................. 3 Safety Information for Users of LP Gas ......................................................................................... ............ 4 Introduction .......... ...

  • Empire Products RH-25-6 - page 3

    Page 3 12821-2-0903 • Due to high temperatures, the room heater should be located out of traffic and away from furniture and drap- eries. • Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in ...

  • Empire Products RH-25-6 - page 4

    Page 4 12821-2-0903 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area ma ...

  • Empire Products RH-25-6 - page 5

    Page 5 12821-2-0903 INTRODUCTION Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installa- tion of a vented room heater. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty ...

  • Empire Products RH-25-6 - page 6

    Page 6 12821-2-0903 Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 1/2" 3/8" 1/2" 3/8" 1.3 cm 1.0 cm 1.3 cm 1.0 cm 10-40 1/2" 1/2" 5/8" 1/2" 1.3 cm 1.3 cm 1.6 cm 1.3 cm 40-100 1/2" 1/2" 3/4" 1/2" 1. ...

  • Empire Products RH-25-6 - page 7

    Page 7 12821-2-0903 CLEARANCES Clearances: When facing the front of the room heater the mini- mum clearances to combustible construction (material) are the following: Right side 6 inches (152mm). Left side 6 inches (152mm). Recommend 18 inches (457mm) on left side for servicing. Do not install in alcove or closet. No horizontal projection above hea ...

  • Empire Products RH-25-6 - page 8

    Page 8 12821-2-0903 VENT SAFETY SHUTOFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. Warning: Operation of this heater, when not connected to a prop- erly installed and maintained venting system or tamper- ing with the vent safety shutoff system, can result in carbon m ...

  • Empire Products RH-25-6 - page 9

    Page 9 12821-2-0903 1. STOP! Read the safety information to the left of this label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 6. Wait ten (10) minutes to clear out any ...

  • Empire Products RH-25-6 - page 10

    Page 10 12821-2-0903 PILOT FLAME CHARACTERISTICS The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting whe ...

  • Empire Products RH-25-6 - page 11

    Page 11 12821-2-0903 To Remove Main Burner 1. Disconnect the thermocouple and pilot supply line at the pilot burner. 2. Unscrew the nut on the orifice fitting union. Orifice fitting is threaded into the main burner. 3. Remove screw on each side of the main burner and lift out. To Remove Main Burner Orifice 1. Unscrew the nut on the orifice fitting ...

  • Empire Products RH-25-6 - page 12

    Page 12 12821-2-0903 INDEX PART NO. NUMBER DESCRIPTION INDEX PART NO. NUMBER DESCRIPTION 1 R-6096 Knob & Adaptor Set 2 11700 Control Rod Bracket 3 R-2706 ECO Switch 4 R-926 Cable Assembly 5 11699 Control Rod 6 R-6104 Gas Valve (LPG) 6 R-6103 Gas Valve (Nat) 7 11697 Valve Bracket 8 RH-705 Casing Side 9 RH-708 Air Inlet Baffle 10 P-86-37 Main Bur ...

  • Empire Products RH-25-6 - page 13

    Page 13 12821-2-0903 P AR TS VIEW ...

  • Empire Products RH-25-6 - page 14

    Page 14 12821-2-0903 DRB-1 For V ented Room Heaters Models RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Dir ect V ent W all Furnaces DV -25-(1, 2)SG and DV -35-(1, 2)SG Installing Optional DRB-1 Blower 1. For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) , remove casing front. 1. For DV-25-(1, 2)SG and DV-35-(1, 2)SG , remove casing front and ...

  • Empire Products RH-25-6 - page 15

    Page 15 12821-2-0903 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1 , if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] pl ...

  • Empire Products RH-25-6 - page 16

    Page 16 12821-2-0903 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen F reeburg A ve. Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: info@empirecomf or t.com WEB SITE: www .empirecomf or t.com ...

Производитель Empire Products Категория Electric Heater

Документы, которые мы получаем от производителя устройства Empire Products RH-25-6 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Empire Products
- инструкции обслуживания RH-25-6
- паспорта изделия Empire Products
- информационные брошюры
- энергетические этикетки Empire Products RH-25-6
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Empire Products RH-25-6.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Empire Products RH-25-6, инструкции обслуживания, короткие инструкции или инструкции пользователя Empire Products RH-25-6. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Empire Products RH-25-6.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Empire Products RH-25-6, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Empire Products RH-25-6 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Empire Products RH-25-6.

Полная инструкция обслуживания Empire Products, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Empire Products RH-25-6 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Empire Products RH-25-6, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Empire Products RH-25-6, которое найдем в данном документе
3. Советы по использованию основных функций устройства Empire Products RH-25-6 - которые должны облегчить нам первые шаги во время использования Empire Products RH-25-6
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Empire Products RH-25-6
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Empire Products RH-25-6 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Empire Products RH-25-6?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Empire Products RH-25-6, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Empire Products RH-25-6 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)