Fujitsu TX150 S4の取扱説明書

18ページ 0.21 mb
ダウンロード

ページに移動 of 18

Summary
  • Fujitsu TX150 S4 - page 1

    PRIMERGY TX 150 S4 System configurator and order-information guide Contents Instructions Configuration diagram Configurator 0 System software I Basic unit II Processor III Memory IV Graphics V Accessible drives VI Hard disk drives VII SCSI Controller VIII Disk array IX Communication/Network X System management options XI Miscellaneous XII Country s ...

  • Fujitsu TX150 S4 - page 2

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Instructions This document contains basic product and configuration information that will enable you to configure your system via PC-/ System-Architect. Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Ra ...

  • Fujitsu TX150 S4 - page 3

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Configuration diagram PRIMERGY TX150 S4 System unit ( I ) SIDE VIEW FRONT VIEW 3 x 5.25" or PS (I) 5.25" x 1.6" 1. PSU 2. PSU Redundant power supply option 5.25" x 1.6" Modul 1 Pentium 4 Modul 3 Modul 2 Accessible drives ( V ) Modul 4 Proces ...

  • Fujitsu TX150 S4 - page 4

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 SW Configurator IA32 with OEM-Software without OEM-Software for PRIMERGY Server for PRIMERGY Server Later use of OEM operating system VMware-Software software is not allowed, - VCMS VirtualCenter Management Server apart from few VMware - GSX ...

  • Fujitsu TX150 S4 - page 5

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 SW Configurator EM64T with OEM-Software without OEM-Software for PRIMERGY Server for PRIMERGY Server Later use of OEM operating system software is not allowed, apart from few VMware add-ons For all SW products please refer to the correspondin ...

  • Fujitsu TX150 S4 - page 6

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 Section I Basic unit System unit consisting of: * Housing including standard power supply (no redundancy) * Sliding screen with lock (only for floorstand version) Systemboard with: * 7 PCI slots: 1x PCIe x 1 1x PCIe x 4 (x8 Slot) 1x PCI-X 66 ...

  • Fujitsu TX150 S4 - page 7

    System configurator and order-information guide A PRIMERGY TX150 S4 Status 25.11.2005 Floorstand version SCSI basic unit 19" Rack version SCSI basic unit (5 U) Pentium 4 processor, memory Pentium 4 processor, memory PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V136 PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V336 PD 820 2.8GHz/800MHz/2x1MB 1G ...

  • Fujitsu TX150 S4 - page 8

    System configurator and order-information guide B1 B2 PRIMERGY TX150 S4 Status 25.11.2005 PRIMERGY Floorstand PRIMERGY Rack PRIMECENTER- Rack SNP:SY-F1647E301-P "rack-mounting ex factory" Installation ex works for one This service is to be ordered once server or subsystem per installable server/storage Hereby the rack will be delivered su ...

  • Fujitsu TX150 S4 - page 9

    System configurator and order-information guide C PRIMERGY TX150 S4 Status 25.11.2005 Section II Processor Section III Memory There are 2 memory banks with 2 DIMM slots each. Single channel memory configuration allow maximum flexibility: Additional memory can be configured as single memory modules. Dual channel memory configurations for maximum per ...

  • Fujitsu TX150 S4 - page 10

    System configurator and order-information guide D PRIMERGY TX150 S4 Status 25.11.2005 Section V Accessible drives There are 3x 5.25" bays for accessible drives: - 1x 5.25" bay is occupied by a DVD-/CD- respectively a CD-RW drive - 2 x 5.25" bays remaining, can be occupied by 2x accessible drives Setup TX150 S4 by ServerStart is suppo ...

  • Fujitsu TX150 S4 - page 11

    System configurator and order-information guide E PRIMERGY TX150 S4 Status 25.11.2005 S26361-F2814-E6 Backup drive and hard disk should run on separate channels 68-Pin Kit for accessible drives Cable with Terminator To connect acc. drives to If internal HDD's are connected at the RAID controller separate SCSI controller (not IME/ZCR), then for ...

  • Fujitsu TX150 S4 - page 12

    System configurator and order-information guide F PRIMERGY TX150 S4 Status 25.11.2005 Section VII SCSI-Controller All internal cables and adapters are included within the basic units and components respectively Cabeling priorities: internal HDs are cabled according to following priorities. (Prio 1 - 3 ): 1.) For a configuration without any Disk Arr ...

  • Fujitsu TX150 S4 - page 13

    System configurator and order-information guide G PRIMERGY TX150 S4 Status 25.11.2005 B. SCSI controller for internal backup drives S26361-F2399-E2 SCSI 160 Controller Adaptec SCSI Card 29160 1 channel: LVD + Fast/ Ultra (decoupl.) LVD connect. for HD, without cable Fast/Ultra connect. for acc. drives 64/66 PCI, min 180 mm int: Fast 50-pin or Ultra ...

  • Fujitsu TX150 S4 - page 14

    System configurator and order-information guide H PRIMERGY TX150 S4 Status 25.11.2005 continued on previous E. 2-Kanal Ultra 320 SCSI Controller für Disk Array page S26361-F3090-E256 2-channel RAID Controller U320 LSI 320-2x 256MB SDRAM ECC Cache 1x default with TBBU plug: internal 2x HD68; external: 2x VHDCI without cable 64/133 PCI-X controller, ...

  • Fujitsu TX150 S4 - page 15

    System configurator and order-information guide I PRIMERGY TX150 S4 Status 25.11.2005 Section IX Communication / Network Gigabit Ethernet Contr. on-board The Intel LAN controllers 1000MT can be used Broadcom with the on-board controller in Teaming Mode ext: for RJ 45-connector SW: AFT, VLAN, Fast Channel S26361-F3053-E1 S26361-F3142-E1 Gigabit Ethe ...

  • Fujitsu TX150 S4 - page 16

    System configurator and order-information guide J PRIMERGY TX150 S4 Status 25.11.2005 Section X System management options S26361-F2425-E103 RSB S2 LP 3HU RemoteView Service Board S2 Low Profile Version with 3 U bracket for one standard PCI-slot incl. cables and RV SW max. 1x per system S26361-F2425-E305 RSB S2 LP external power supply RemoteView Se ...

  • Fujitsu TX150 S4 - page 17

    System configurator and order-information guide K PRIMERGY TX150 S4 Status 25.11.2005 Section XII Country specific / rack specific options A country specific power cord has to be ordered for all floorstand versions: - once per basic unit and an additional second cable - if an second hot plug, redundant power supply modul is ordered. PRIMERGY TX150 ...

  • Fujitsu TX150 S4 - page 18

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Cange Report Date Order number Changes 2005-11-23 S26361-F1809-E2 ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 - now available 2005-03-31 First release Fujitsu Siemens Computers Enterprise Products - PRIMERGY Server 18 of 18 ...

メーカー Fujitsu カテゴリー Server

Fujitsu TX150 S4のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TX150 S4の取扱説明書
- Fujitsuの製品カード
- パンフレット
- またはFujitsu TX150 S4の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Fujitsu TX150 S4の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Fujitsu TX150 S4の取り付け説明書、サービスマニュアル、簡易説明書、またはFujitsu TX150 S4のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Fujitsu TX150 S4の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Fujitsu TX150 S4デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFujitsu TX150 S4を使用するのを助ける技術的文書のことです。説明書は通常、全てのFujitsu TX150 S4ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Fujitsuの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Fujitsu TX150 S4の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFujitsu TX150 S4の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Fujitsu TX150 S4に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Fujitsu TX150 S4デバイスの基本機能を使うにあたってのヒント。 Fujitsu TX150 S4のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Fujitsu TX150 S4に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFujitsu TX150 S4のメーカー/サービスへの連絡先に関する情報。

Fujitsu TX150 S4についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFujitsu TX150 S4の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFujitsu TX150 S4で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)