Инструкция обслуживания Fujitsu TX150 S4

18 страниц 0.21 mb
Скачать

Перейти на страницу of 18

Summary
  • Fujitsu TX150 S4 - page 1

    PRIMERGY TX 150 S4 System configurator and order-information guide Contents Instructions Configuration diagram Configurator 0 System software I Basic unit II Processor III Memory IV Graphics V Accessible drives VI Hard disk drives VII SCSI Controller VIII Disk array IX Communication/Network X System management options XI Miscellaneous XII Country s ...

  • Fujitsu TX150 S4 - page 2

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Instructions This document contains basic product and configuration information that will enable you to configure your system via PC-/ System-Architect. Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Ra ...

  • Fujitsu TX150 S4 - page 3

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Configuration diagram PRIMERGY TX150 S4 System unit ( I ) SIDE VIEW FRONT VIEW 3 x 5.25" or PS (I) 5.25" x 1.6" 1. PSU 2. PSU Redundant power supply option 5.25" x 1.6" Modul 1 Pentium 4 Modul 3 Modul 2 Accessible drives ( V ) Modul 4 Proces ...

  • Fujitsu TX150 S4 - page 4

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 SW Configurator IA32 with OEM-Software without OEM-Software for PRIMERGY Server for PRIMERGY Server Later use of OEM operating system VMware-Software software is not allowed, - VCMS VirtualCenter Management Server apart from few VMware - GSX ...

  • Fujitsu TX150 S4 - page 5

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 SW Configurator EM64T with OEM-Software without OEM-Software for PRIMERGY Server for PRIMERGY Server Later use of OEM operating system software is not allowed, apart from few VMware add-ons For all SW products please refer to the correspondin ...

  • Fujitsu TX150 S4 - page 6

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 Section I Basic unit System unit consisting of: * Housing including standard power supply (no redundancy) * Sliding screen with lock (only for floorstand version) Systemboard with: * 7 PCI slots: 1x PCIe x 1 1x PCIe x 4 (x8 Slot) 1x PCI-X 66 ...

  • Fujitsu TX150 S4 - page 7

    System configurator and order-information guide A PRIMERGY TX150 S4 Status 25.11.2005 Floorstand version SCSI basic unit 19" Rack version SCSI basic unit (5 U) Pentium 4 processor, memory Pentium 4 processor, memory PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V136 PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V336 PD 820 2.8GHz/800MHz/2x1MB 1G ...

  • Fujitsu TX150 S4 - page 8

    System configurator and order-information guide B1 B2 PRIMERGY TX150 S4 Status 25.11.2005 PRIMERGY Floorstand PRIMERGY Rack PRIMECENTER- Rack SNP:SY-F1647E301-P "rack-mounting ex factory" Installation ex works for one This service is to be ordered once server or subsystem per installable server/storage Hereby the rack will be delivered su ...

  • Fujitsu TX150 S4 - page 9

    System configurator and order-information guide C PRIMERGY TX150 S4 Status 25.11.2005 Section II Processor Section III Memory There are 2 memory banks with 2 DIMM slots each. Single channel memory configuration allow maximum flexibility: Additional memory can be configured as single memory modules. Dual channel memory configurations for maximum per ...

  • Fujitsu TX150 S4 - page 10

    System configurator and order-information guide D PRIMERGY TX150 S4 Status 25.11.2005 Section V Accessible drives There are 3x 5.25" bays for accessible drives: - 1x 5.25" bay is occupied by a DVD-/CD- respectively a CD-RW drive - 2 x 5.25" bays remaining, can be occupied by 2x accessible drives Setup TX150 S4 by ServerStart is suppo ...

  • Fujitsu TX150 S4 - page 11

    System configurator and order-information guide E PRIMERGY TX150 S4 Status 25.11.2005 S26361-F2814-E6 Backup drive and hard disk should run on separate channels 68-Pin Kit for accessible drives Cable with Terminator To connect acc. drives to If internal HDD's are connected at the RAID controller separate SCSI controller (not IME/ZCR), then for ...

  • Fujitsu TX150 S4 - page 12

    System configurator and order-information guide F PRIMERGY TX150 S4 Status 25.11.2005 Section VII SCSI-Controller All internal cables and adapters are included within the basic units and components respectively Cabeling priorities: internal HDs are cabled according to following priorities. (Prio 1 - 3 ): 1.) For a configuration without any Disk Arr ...

  • Fujitsu TX150 S4 - page 13

    System configurator and order-information guide G PRIMERGY TX150 S4 Status 25.11.2005 B. SCSI controller for internal backup drives S26361-F2399-E2 SCSI 160 Controller Adaptec SCSI Card 29160 1 channel: LVD + Fast/ Ultra (decoupl.) LVD connect. for HD, without cable Fast/Ultra connect. for acc. drives 64/66 PCI, min 180 mm int: Fast 50-pin or Ultra ...

  • Fujitsu TX150 S4 - page 14

    System configurator and order-information guide H PRIMERGY TX150 S4 Status 25.11.2005 continued on previous E. 2-Kanal Ultra 320 SCSI Controller für Disk Array page S26361-F3090-E256 2-channel RAID Controller U320 LSI 320-2x 256MB SDRAM ECC Cache 1x default with TBBU plug: internal 2x HD68; external: 2x VHDCI without cable 64/133 PCI-X controller, ...

  • Fujitsu TX150 S4 - page 15

    System configurator and order-information guide I PRIMERGY TX150 S4 Status 25.11.2005 Section IX Communication / Network Gigabit Ethernet Contr. on-board The Intel LAN controllers 1000MT can be used Broadcom with the on-board controller in Teaming Mode ext: for RJ 45-connector SW: AFT, VLAN, Fast Channel S26361-F3053-E1 S26361-F3142-E1 Gigabit Ethe ...

  • Fujitsu TX150 S4 - page 16

    System configurator and order-information guide J PRIMERGY TX150 S4 Status 25.11.2005 Section X System management options S26361-F2425-E103 RSB S2 LP 3HU RemoteView Service Board S2 Low Profile Version with 3 U bracket for one standard PCI-slot incl. cables and RV SW max. 1x per system S26361-F2425-E305 RSB S2 LP external power supply RemoteView Se ...

  • Fujitsu TX150 S4 - page 17

    System configurator and order-information guide K PRIMERGY TX150 S4 Status 25.11.2005 Section XII Country specific / rack specific options A country specific power cord has to be ordered for all floorstand versions: - once per basic unit and an additional second cable - if an second hot plug, redundant power supply modul is ordered. PRIMERGY TX150 ...

  • Fujitsu TX150 S4 - page 18

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Cange Report Date Order number Changes 2005-11-23 S26361-F1809-E2 ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 - now available 2005-03-31 First release Fujitsu Siemens Computers Enterprise Products - PRIMERGY Server 18 of 18 ...

Производитель Fujitsu Категория Server

Документы, которые мы получаем от производителя устройства Fujitsu TX150 S4 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Fujitsu
- инструкции обслуживания TX150 S4
- паспорта изделия Fujitsu
- информационные брошюры
- энергетические этикетки Fujitsu TX150 S4
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Fujitsu TX150 S4.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Fujitsu TX150 S4, инструкции обслуживания, короткие инструкции или инструкции пользователя Fujitsu TX150 S4. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Fujitsu TX150 S4.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Fujitsu TX150 S4, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Fujitsu TX150 S4 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Fujitsu TX150 S4.

Полная инструкция обслуживания Fujitsu, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Fujitsu TX150 S4 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Fujitsu TX150 S4, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Fujitsu TX150 S4, которое найдем в данном документе
3. Советы по использованию основных функций устройства Fujitsu TX150 S4 - которые должны облегчить нам первые шаги во время использования Fujitsu TX150 S4
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Fujitsu TX150 S4
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Fujitsu TX150 S4 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Fujitsu TX150 S4?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Fujitsu TX150 S4, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Fujitsu TX150 S4 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)