Manual Fujitsu TX150 S4

18 pages 0.21 mb
Download

Go to site of 18

Summary
  • Fujitsu TX150 S4 - page 1

    PRIMERGY TX 150 S4 System configurator and order-information guide Contents Instructions Configuration diagram Configurator 0 System software I Basic unit II Processor III Memory IV Graphics V Accessible drives VI Hard disk drives VII SCSI Controller VIII Disk array IX Communication/Network X System management options XI Miscellaneous XII Country s ...

  • Fujitsu TX150 S4 - page 2

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Instructions This document contains basic product and configuration information that will enable you to configure your system via PC-/ System-Architect. Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Ra ...

  • Fujitsu TX150 S4 - page 3

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Configuration diagram PRIMERGY TX150 S4 System unit ( I ) SIDE VIEW FRONT VIEW 3 x 5.25" or PS (I) 5.25" x 1.6" 1. PSU 2. PSU Redundant power supply option 5.25" x 1.6" Modul 1 Pentium 4 Modul 3 Modul 2 Accessible drives ( V ) Modul 4 Proces ...

  • Fujitsu TX150 S4 - page 4

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 SW Configurator IA32 with OEM-Software without OEM-Software for PRIMERGY Server for PRIMERGY Server Later use of OEM operating system VMware-Software software is not allowed, - VCMS VirtualCenter Management Server apart from few VMware - GSX ...

  • Fujitsu TX150 S4 - page 5

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 SW Configurator EM64T with OEM-Software without OEM-Software for PRIMERGY Server for PRIMERGY Server Later use of OEM operating system software is not allowed, apart from few VMware add-ons For all SW products please refer to the correspondin ...

  • Fujitsu TX150 S4 - page 6

    System configurator and order-information guide Start PRIMERGY TX150 S4 PRIMERGY TX150 S4 Status 25.11.2005 Section I Basic unit System unit consisting of: * Housing including standard power supply (no redundancy) * Sliding screen with lock (only for floorstand version) Systemboard with: * 7 PCI slots: 1x PCIe x 1 1x PCIe x 4 (x8 Slot) 1x PCI-X 66 ...

  • Fujitsu TX150 S4 - page 7

    System configurator and order-information guide A PRIMERGY TX150 S4 Status 25.11.2005 Floorstand version SCSI basic unit 19" Rack version SCSI basic unit (5 U) Pentium 4 processor, memory Pentium 4 processor, memory PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V136 PD 820 2.8GHz/800MHz/2x1MB 512MB S26361-K999-V336 PD 820 2.8GHz/800MHz/2x1MB 1G ...

  • Fujitsu TX150 S4 - page 8

    System configurator and order-information guide B1 B2 PRIMERGY TX150 S4 Status 25.11.2005 PRIMERGY Floorstand PRIMERGY Rack PRIMECENTER- Rack SNP:SY-F1647E301-P "rack-mounting ex factory" Installation ex works for one This service is to be ordered once server or subsystem per installable server/storage Hereby the rack will be delivered su ...

  • Fujitsu TX150 S4 - page 9

    System configurator and order-information guide C PRIMERGY TX150 S4 Status 25.11.2005 Section II Processor Section III Memory There are 2 memory banks with 2 DIMM slots each. Single channel memory configuration allow maximum flexibility: Additional memory can be configured as single memory modules. Dual channel memory configurations for maximum per ...

  • Fujitsu TX150 S4 - page 10

    System configurator and order-information guide D PRIMERGY TX150 S4 Status 25.11.2005 Section V Accessible drives There are 3x 5.25" bays for accessible drives: - 1x 5.25" bay is occupied by a DVD-/CD- respectively a CD-RW drive - 2 x 5.25" bays remaining, can be occupied by 2x accessible drives Setup TX150 S4 by ServerStart is suppo ...

  • Fujitsu TX150 S4 - page 11

    System configurator and order-information guide E PRIMERGY TX150 S4 Status 25.11.2005 S26361-F2814-E6 Backup drive and hard disk should run on separate channels 68-Pin Kit for accessible drives Cable with Terminator To connect acc. drives to If internal HDD's are connected at the RAID controller separate SCSI controller (not IME/ZCR), then for ...

  • Fujitsu TX150 S4 - page 12

    System configurator and order-information guide F PRIMERGY TX150 S4 Status 25.11.2005 Section VII SCSI-Controller All internal cables and adapters are included within the basic units and components respectively Cabeling priorities: internal HDs are cabled according to following priorities. (Prio 1 - 3 ): 1.) For a configuration without any Disk Arr ...

  • Fujitsu TX150 S4 - page 13

    System configurator and order-information guide G PRIMERGY TX150 S4 Status 25.11.2005 B. SCSI controller for internal backup drives S26361-F2399-E2 SCSI 160 Controller Adaptec SCSI Card 29160 1 channel: LVD + Fast/ Ultra (decoupl.) LVD connect. for HD, without cable Fast/Ultra connect. for acc. drives 64/66 PCI, min 180 mm int: Fast 50-pin or Ultra ...

  • Fujitsu TX150 S4 - page 14

    System configurator and order-information guide H PRIMERGY TX150 S4 Status 25.11.2005 continued on previous E. 2-Kanal Ultra 320 SCSI Controller für Disk Array page S26361-F3090-E256 2-channel RAID Controller U320 LSI 320-2x 256MB SDRAM ECC Cache 1x default with TBBU plug: internal 2x HD68; external: 2x VHDCI without cable 64/133 PCI-X controller, ...

  • Fujitsu TX150 S4 - page 15

    System configurator and order-information guide I PRIMERGY TX150 S4 Status 25.11.2005 Section IX Communication / Network Gigabit Ethernet Contr. on-board The Intel LAN controllers 1000MT can be used Broadcom with the on-board controller in Teaming Mode ext: for RJ 45-connector SW: AFT, VLAN, Fast Channel S26361-F3053-E1 S26361-F3142-E1 Gigabit Ethe ...

  • Fujitsu TX150 S4 - page 16

    System configurator and order-information guide J PRIMERGY TX150 S4 Status 25.11.2005 Section X System management options S26361-F2425-E103 RSB S2 LP 3HU RemoteView Service Board S2 Low Profile Version with 3 U bracket for one standard PCI-slot incl. cables and RV SW max. 1x per system S26361-F2425-E305 RSB S2 LP external power supply RemoteView Se ...

  • Fujitsu TX150 S4 - page 17

    System configurator and order-information guide K PRIMERGY TX150 S4 Status 25.11.2005 Section XII Country specific / rack specific options A country specific power cord has to be ordered for all floorstand versions: - once per basic unit and an additional second cable - if an second hot plug, redundant power supply modul is ordered. PRIMERGY TX150 ...

  • Fujitsu TX150 S4 - page 18

    System configurator and order-information guide PRIMERGY TX150 S4 Status 25.11.2005 Cange Report Date Order number Changes 2005-11-23 S26361-F1809-E2 ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 - now available 2005-03-31 First release Fujitsu Siemens Computers Enterprise Products - PRIMERGY Server 18 of 18 ...

Manufacturer Fujitsu Category Server

Documents that we receive from a manufacturer of a Fujitsu TX150 S4 can be divided into several groups. They are, among others:
- Fujitsu technical drawings
- TX150 S4 manuals
- Fujitsu product data sheets
- information booklets
- or energy labels Fujitsu TX150 S4
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fujitsu TX150 S4.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fujitsu TX150 S4, service manual, brief instructions and user manuals Fujitsu TX150 S4. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fujitsu TX150 S4.

Similar manuals

A complete manual for the device Fujitsu TX150 S4, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fujitsu TX150 S4 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fujitsu TX150 S4.

A complete Fujitsu manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fujitsu TX150 S4 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fujitsu TX150 S4, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fujitsu TX150 S4, that we can find in the current document
3. Tips how to use the basic functions of the device Fujitsu TX150 S4 - which should help us in our first steps of using Fujitsu TX150 S4
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fujitsu TX150 S4
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fujitsu TX150 S4 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fujitsu TX150 S4?

Use the form below

If you did not solve your problem by using a manual Fujitsu TX150 S4, ask a question using the form below. If a user had a similar problem with Fujitsu TX150 S4 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)