    Important safety instructions! Please read this manual! V euillez lire ce manuel! Bitte lesen Sie dieses Anleitungshandbuch! ¡Se ruega leer este manual de instrucciones! PLEASE SA VE THIS MANUAL ! It includes important instructions for the safe use and installation of the UPS and its accessories. CONSERVER CES INSTRUCTIONS ! Cette notice contient ...

  • American Power Conversion MXA002 - page 3

    Page 1 T able of contents 1.0 Introduction ................................................................................. 2 2.0 Presentation ................................................................................. 3 3. 0 Installation ................................................................................... 4 Input voltage requ ...

  • American Power Conversion MXA002 - page 4

    Page 2 1.0 Introduction The hard-wire kit allows the UPS's input and/or output terminals to be permanently secured to building service wiring. This kit is used in place of the power distribution plate and/or input cable plate originally furnished with the UPS. The kit contains input cable and output power distribution plates with "knock-o ...

  • American Power Conversion MXA002 - page 5

    Page 3 2.0 Presentation Power distribution plate Provides an interface for output hard-wiring of loads. It is used in place of the power distribution plate for cord connected equipment originally furnished with the UPS. Input cable plate Used to replace the input cable plate originally furnished with the UPS. It allows hard-wiring of the input conn ...

  • American Power Conversion MXA002 - page 6

    Page 4 3.0 Installation ■ W arning: Risk of electric shock exists inside the UPS. Input voltage tap selection and power distribution panel replacement should be performed only by qualified service personnel. ■ A vertissement: Un risque de choc électrique existe à lintérieur de lUPS. La sélection des fils de tension dentrée et le r ...

  • American Power Conversion MXA002 - page 7

    Page 5 3.0 Installation T able 3.2.1 Cable Size S tri p Length UP S M ode l Min im um Ma x i m um Input cable Output cable 300 0VA 2. 5 m m 2 12 A W G 1 0 .0 m m 2 8 AW G 12 m m 1/2" 9 m m 3/8" 500 0VA 6. 0 m m 2 10 A W G 1 0 .0 m m 2 8 AW G ■ Cable clamps The UPS is not furnished with cable clamps for strain relief. Use only approved ? ...

  • American Power Conversion MXA002 - page 8

    Page 6 3.0 Installation Input cable connections 3.3 Input wiring procedure - continued T o remove a knock-out, strike in the area shown with a nail set tool and hammer . Grasp the edge of the knock-out with pliers and twist until the knock-out is separated from the plate. Caution: The edge of the knock-out may be sharp! Example showing removal of ? ...

  • American Power Conversion MXA002 - page 9

    Page 7 3.0 Installation 3.3 Input wiring procedure - continued 3.3.4 Remove all three input cable wire connections from terminal block labeled L1 , and L2/N . 3.3.5 Remove all screws that secure the input cable plate. Use a pair of wire cutters to remove "tie wraps" binding the input cable to wires inside the Isolation Unit. T ake care no ...

  • American Power Conversion MXA002 - page 10

    Page 8 Unmating of UPS output power connector 3.0 Installation 3.4 Output wiring procedure 3.4.1 Be sure the input circuit breaker is switched off (0) and the input cable is unplugged and/ or has no power applied. Caution: Switching the circuit breaker to off (0) does not remove power to all of the Isolation Unit. Power to the UPS must be disconnec ...

  • American Power Conversion MXA002 - page 11

    Page 9 Diagram showing power distribution plate earth connection 3.0 Installation 3.4 Output wiring procedure - continued 3.4.4 Use a 3/8" wrench to remove the protective earth wire (green with yellow stripes) ring terminal fastened at the earthing stud on the Isolation Unit. 3.4.5 Remove the desired knock-out from the new power distribution p ...

  • American Power Conversion MXA002 - page 12

    Page 10 3.0 Installation 3.4 Output wiring procedure - continued 3.4.9 Choose the desired wiring connections from the illustrations on the following pages (Figure 3.4.1 through Figure 3.4.6 ). Insert the stripped wire ends into the appropriate output terminations block terminal and tighten the terminal screws. Caution: Overcurrent protection for ou ...

  • American Power Conversion MXA002 - page 13

    Page 11 3.0 Installation 3.4 Output wiring procedure - continued Figure 3.4.1 1 f , 208 V ac loads only 3000 V A model with MXA002 hard- wire kit: 15 Amp maximum. 5000 V A model with MXA001 hard- wire kit: 24 Amp maximum. Figure 3.4.2 1 f , 240 V ac loads only 3000 V A model with MXA002 hard- wire kit: 12.5 Amp maximum. 5000 V A model with MXA001 h ...

  • American Power Conversion MXA002 - page 14

    Page 12 3.0 Installation 3.4 Output wiring procedure - continued Figure 3.4.5 1 f , 120/240 V ac loads ■ ■ ■ ■ ■ 3000 V A model with MXA002 hard- wire kit Each 120 V ac output: 25 Amp maxi- mum. 240 V ac output: 12.5 Amp maximum. T otal output: not to exceed 3000 V A . ■ ■ ■ ■ ■ 5000 V A model with MXA001 hard- wire kit Each 120 ...

  • American Power Conversion MXA002 - page 15

    Limited W arranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obta ...

  • American Power Conversion MXA002 - page 16

    Customer Service Note: Before calling the customer service number , please have available your UPS's serial number (see the label at the rear of the UPS). ( PHONE (+33) 1.64.62.59.00 in Europe (401) 789-5735 world wide * MAILING American Power Conversion 4, rue Ste Claire Deville Zac du Mandinet-Bâtiment Espace LOGNES 77447 MARNE LA V ALLEE C ...

Manufacturer American Power Conversion Category Power Supply

Documents that we receive from a manufacturer of a American Power Conversion MXA002 can be divided into several groups. They are, among others:
- American Power Conversion technical drawings
- MXA002 manuals
- American Power Conversion product data sheets
- information booklets
- or energy labels American Power Conversion MXA002
All of them are important, but the most important information from the point of view of use of the device are in the user manual American Power Conversion MXA002.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals American Power Conversion MXA002, service manual, brief instructions and user manuals American Power Conversion MXA002. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product American Power Conversion MXA002.

A complete manual for the device American Power Conversion MXA002, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use American Power Conversion MXA002 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of American Power Conversion MXA002.

A complete American Power Conversion manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual American Power Conversion MXA002 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the American Power Conversion MXA002, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the American Power Conversion MXA002, that we can find in the current document
3. Tips how to use the basic functions of the device American Power Conversion MXA002 - which should help us in our first steps of using American Power Conversion MXA002
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with American Power Conversion MXA002
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of American Power Conversion MXA002 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning American Power Conversion MXA002?

Use the form below

If you did not solve your problem by using a manual American Power Conversion MXA002, ask a question using the form below. If a user had a similar problem with American Power Conversion MXA002 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)